NYC OATH / ECB — Hearing Date PassedBIN 3429584, Brooklyn, NY — NYC OATH Hearing & Violation Status Review
The scheduled OATH hearing date listed for this property has passed. The date alone does not establish the disposition; current OATH and DOB records should be reviewed to determine the present status and any next steps.
Property location
- Property address
- BIN 3429584, Brooklyn, NY
- Borough
- Brooklyn
- BIN
- 3429584
- Block/Lot
- 3/426/1
- Hearing month
- August 2026
- Violation records on this page
- 5
Hearing records
| ECB violation # | Hearing date | Severity | Violation category | Balance due |
|---|
| 39554389P | August 5, 2026 10:30 AM | CLASS - 1 | Required inspection or equipment compliance issue | $2,500 |
| 39554388N | August 5, 2026 9:30 AM | CLASS - 1 | Required inspection or equipment compliance issue | $5,000 |
| 39554707L | August 5, 2026 10:30 AM | CLASS - 1 | Required inspection or equipment compliance issue | $5,000 |
| 39555154P | August 12, 2026 8:30 AM | CLASS - 2 | Required inspection or equipment compliance issue | $2,500 |
| 39555155R | August 12, 2026 9:30 AM | CLASS - 2 | Failure to maintain building in code-compliant condition | $1,250 |
Property-specific hearing analysis for BIN 3429584, Brooklyn, NY
This page focuses on BIN 3429584, Brooklyn, NY and the August 2026 OATH hearing records connected to that property. The public file lists 5 hearing records, with category work involving Elevator / Conveyance Equipment, Construction Site Safety / Public Protection, Required Inspection / Filing Compliance.
The property is listed in Brooklyn. The source extract used to build this page showed hearing status values of PENDING, severity values of CLASS - 1, CLASS - 2, and hearing date information of August 12, 2026, August 5, 2026. Those source values are historical and should not be treated as the current OATH or DOB disposition after the hearing date.
Estimated listed balance across these records is $16,250. Always verify the current balance and status with NYC OATH/DOB because defaults, payments, settlements, and certifications can change after export.
For owners, brokers, buyers, attorneys, contractors, and managers connected to this property, the practical question is whether there is enough proof, permit history, correction documentation, or professional support to reduce risk and close the matter properly.
Why this Brooklyn hearing record matters
BIN 3429584, Brooklyn, NY should be reviewed as a specific property file, not as a generic DOB matter. The borough, BIN, block/lot, public description, and hearing status all affect the correction path and the documents that should be gathered.
A useful review compares the OATH record against DOB BIS, permit history, complaint history, open job filings, and any physical correction already performed at the premises.
Category-specific strategy for this property
Elevator / Conveyance Equipment strategy at this property
This category concerns elevator or conveyance compliance, inspection, maintenance, testing, or required filing obligations.
Elevator violations can affect tenant safety, insurance, and building operations.
Construction Site Safety / Public Protection strategy at this property
This category concerns construction-site safety, public protection, watchperson requirements, guardrails, fences, sheds, sidewalk protection, or access controls.
Site-safety hearings can involve large penalties because DOB treats public and worker protection as urgent.
Required Inspection / Filing Compliance strategy at this property
This category concerns a required inspection, filing, report, registration, or certification obligation connected to building systems or site conditions.
Inspection and filing problems can stay open even when the physical condition is resolved.
August 2026 hearing records with record-specific analysis
Each record below uses the public violation description, cited law references, status, severity, and listed balance to create a more specific post-hearing review summary.
Record 1: ECB Violation #39554389P — Elevator / Conveyance Equipment
Hearing dateAugust 5, 2026
Hearing time10:30 AM
Source hearing status (at extract)PENDING
SeverityCLASS - 1
Violation typeUnknown
Source-listed balance$2,500
Issue dateMay 20, 2026
Served dateMay 20, 2026
What the source record says
The public description for BIN 3429584, Brooklyn, NY states: “AT TIME OF INSPECTION, WORKER OBSERVED OPERATING SCISSOR LIFT AT LEADING EDGE OF BUILDING WITHOUT REQUIRED OPERATOR TRAINING AND CONTRARY TO MANUFACTURER SPECIFICATIONS FOR AERIAL LIFT OPERATION, CONTRARY TO BC”
What this category usually means
This category concerns elevator or conveyance compliance, inspection, maintenance, testing, or required filing obligations.
What a hearing on this record may have focused on
The hearing may look at required inspections, tests, reports, unsafe equipment, and contractor records.
Documents and proof worth reviewing now
- inspection reports
- elevator company invoices
- DOB filing confirmations
- repair documentation
Why this should not be ignored
Elevator violations can affect tenant safety, insurance, and building operations.
Cited law / infraction references Record 2: ECB Violation #39554388N — Construction Site Safety / Public Protection
Hearing dateAugust 5, 2026
Hearing time9:30 AM
Source hearing status (at extract)PENDING
SeverityCLASS - 1
Violation typeUnknown
Source-listed balance$5,000
Issue dateMay 20, 2026
Served dateMay 20, 2026
What the source record says
The public description for BIN 3429584, Brooklyn, NY states: “AT TIME OF INSPECTION, OBSERVED SUPPORTED SCAFFOLD THROUGHOUT JOB SITE, CONTRARY TO APPROVED DRAWINGS, INCLUDING TIE-INS NOT INSTALLED AT LOCATIONS INDICATED ON APPROVED DRAWINGS. IN ADDITION, GUARDRAILS AND EN” Site-safety proof should be dated because DOB focuses on conditions at the inspection time.
What this category usually means
This category concerns construction-site safety, public protection, watchperson requirements, guardrails, fences, sheds, sidewalk protection, or access controls.
What a hearing on this record may have focused on
The hearing may examine whether required protection was in place at the inspection time and whether the cited party controlled the work.
Documents and proof worth reviewing now
- contractor daily reports
- permits
- watchperson records
- site safety logs
- protection photos
Why this should not be ignored
Site-safety hearings can involve large penalties because DOB treats public and worker protection as urgent.
Cited law / infraction references Record 3: ECB Violation #39554707L — Required Inspection / Filing Compliance
Hearing dateAugust 5, 2026
Hearing time10:30 AM
Source hearing status (at extract)PENDING
SeverityCLASS - 1
Violation typeUnknown
Source-listed balance$5,000
Issue dateMay 28, 2026
Served dateMay 28, 2026
What the source record says
The public description for BIN 3429584, Brooklyn, NY states: “AT TIME OF INSPECTION, FOLLOWING WORKER INJURY INCIDENT REPORTED UNDER COMPLAINT #3A61945 ON 05/13/2026, PERMIT HOLDER FAILED TO REPORT REQUIRED INCIDENT INFORMATION TO THE DEPARTMENT WITHIN THREE BUSINESS DAYS”
What this category usually means
This category concerns a required inspection, filing, report, registration, or certification obligation connected to building systems or site conditions.
What a hearing on this record may have focused on
The hearing should focus on whether the inspection or filing was completed, whether it was accepted, and whether records can be produced.
Documents and proof worth reviewing now
- inspection reports
- filing confirmations
- service invoices
- repair photos
- accepted correction records
Why this should not be ignored
Inspection and filing problems can stay open even when the physical condition is resolved.
Cited law / infraction references Record 4: ECB Violation #39555154P — Construction Site Safety / Public Protection
Hearing dateAugust 12, 2026
Hearing time8:30 AM
Source hearing status (at extract)PENDING
SeverityCLASS - 2
Violation typeUnknown
Source-listed balance$2,500
Issue dateJune 7, 2026
Served dateJune 7, 2026
What the source record says
The public description for BIN 3429584, Brooklyn, NY states: “BC 3314 .1 AT THE TIME OF INSPECTION OF THE 10-STORY NEW BUILDING, PIPE SCAFFOLD AT EXP# 1-4 WAS NOT MAINTAINED. DEBRIS NETTING CONTAINED LARGE OPENINGS, MULTIPLE PINS WERE MISSING, AND LOOSE PLANKING WAS NOT S”
What this category usually means
This category concerns construction-site safety, public protection, watchperson requirements, guardrails, fences, sheds, sidewalk protection, or access controls.
What a hearing on this record may have focused on
The hearing may examine whether required protection was in place at the inspection time and whether the cited party controlled the work.
Documents and proof worth reviewing now
- contractor daily reports
- permits
- watchperson records
- site safety logs
- protection photos
Why this should not be ignored
Site-safety hearings can involve large penalties because DOB treats public and worker protection as urgent.
Cited law / infraction references Record 5: ECB Violation #39555155R — Required Inspection / Filing Compliance
Hearing dateAugust 12, 2026
Hearing time9:30 AM
Source hearing status (at extract)PENDING
SeverityCLASS - 2
Violation typeConstruction
Source-listed balance$1,250
Issue dateJune 7, 2026
Served dateJune 7, 2026
What the source record says
The public description for BIN 3429584, Brooklyn, NY states: “BC 3301.1.3 AT TIME OF INSPECTION, A YODOCK BARRIER SYSTEM WAS OBSERVED WITH MISSING INTERLOCKING COUPLERS THROUGHOUT AND BARRIERS NOT ALL FILLED WITH WATER OR SAND AS REQUIRED. THIS CONDITION CREATES A SAFETY”
What this category usually means
This category concerns a required inspection, filing, report, registration, or certification obligation connected to building systems or site conditions.
What a hearing on this record may have focused on
The hearing should focus on whether the inspection or filing was completed, whether it was accepted, and whether records can be produced.
Documents and proof worth reviewing now
- inspection reports
- filing confirmations
- service invoices
- repair photos
- accepted correction records
Why this should not be ignored
Inspection and filing problems can stay open even when the physical condition is resolved.
Cited law / infraction references- 2F6 BC 3301.1.3 (2014 CODE) FAILURE TO COMPLY WITH MANUFACTURER SPECIFICATIONS
Questions specific to this type of OATH hearing
What should be reviewed now for this elevator / conveyance equipment record?
Start by confirming the current OATH/DOB status, the exact public description, law section, responsible party, correction evidence, later hearing activity, payments or judgments, and any filing or certification activity that occurred after the original source extract.
What should be reviewed now for this construction site safety / public protection record?
Start by confirming the current OATH/DOB status, the exact public description, law section, responsible party, correction evidence, later hearing activity, payments or judgments, and any filing or certification activity that occurred after the original source extract.
What should be reviewed now for this required inspection / filing compliance record?
Start by confirming the current OATH/DOB status, the exact public description, law section, responsible party, correction evidence, later hearing activity, payments or judgments, and any filing or certification activity that occurred after the original source extract.
Why would someone search BIN 3429584, Brooklyn, NY?
Owners, real estate professionals, contractors, buyers, attorneys, and lenders may search BIN 3429584, Brooklyn, NY when they see an OATH hearing, open DOB/ECB record, title issue, or upcoming transaction connected to the property.
Need a current record review for BIN 3429584, Brooklyn, NY?
The original hearing date has passed. Current agency records—not the old scheduled date—should control the next decision. Building Violation LLC can scope a paid current-status review and any follow-up work that the records support.
Request Current Status ReviewCall (866) 545-4440