← August 2026 NYC OATH hearings list
NYC OATH / ECB — Hearing Date Passed

BIN 4006772, Queens, NY — NYC OATH Hearing & Violation Status Review

The scheduled OATH hearing date listed for this property has passed. The date alone does not establish the disposition; current OATH and DOB records should be reviewed to determine the present status and any next steps.

Need to know what happened after the hearing?

Building Violation LLC can review available current property, summons, OATH, DOB and related agency records, then identify an appropriate paid scope for further assistance. No hearing outcome is assumed from the date shown on this page.

Review Current Status for BIN 4006772, Queens, NYCall (866) 545-4440Email us

Property location

Property address
BIN 4006772, Queens, NY
Borough
Queens
BIN
4006772
Block/Lot
4/572/31
Hearing month
August 2026
Violation records on this page
2

Hearing records

ECB violation #Hearing dateSeverityViolation categoryBalance due
39554700ZAugust 4, 2026
8:30 AM
CLASS - 2Failure to maintain building in code-compliant condition$1,250
39554701KAugust 4, 2026
10:30 AM
CLASS - 2Work without permit$1,250

Property-specific hearing analysis for BIN 4006772, Queens, NY

This page focuses on BIN 4006772, Queens, NY and the August 2026 OATH hearing records connected to that property. The public file lists 2 hearing records, with category work involving Failure to Maintain / Unsafe Condition, Construction Site Safety / Public Protection.

The property is listed in Queens. The source extract used to build this page showed hearing status values of PENDING, severity values of CLASS - 2, and hearing date information of August 4, 2026. Those source values are historical and should not be treated as the current OATH or DOB disposition after the hearing date.

Estimated listed balance across these records is $2,500. Always verify the current balance and status with NYC OATH/DOB because defaults, payments, settlements, and certifications can change after export.

For owners, brokers, buyers, attorneys, contractors, and managers connected to this property, the practical question is whether there is enough proof, permit history, correction documentation, or professional support to reduce risk and close the matter properly.

Why this Queens hearing record matters

BIN 4006772, Queens, NY should be reviewed as a specific property file, not as a generic DOB matter. The borough, BIN, block/lot, public description, and hearing status all affect the correction path and the documents that should be gathered.

A useful review compares the OATH record against DOB BIS, permit history, complaint history, open job filings, and any physical correction already performed at the premises.

Category-specific strategy for this property

Failure to Maintain / Unsafe Condition strategy at this property

This category usually concerns a building, structure, lot, wall, roof, opening, or component allegedly not maintained in safe code-compliant condition.

Unsafe-condition records can trigger emergency repairs, reinspections, civil penalties, and transaction delays.

Construction Site Safety / Public Protection strategy at this property

This category concerns construction-site safety, public protection, watchperson requirements, guardrails, fences, sheds, sidewalk protection, or access controls.

Site-safety hearings can involve large penalties because DOB treats public and worker protection as urgent.

August 2026 hearing records with record-specific analysis

Each record below uses the public violation description, cited law references, status, severity, and listed balance to create a more specific post-hearing review summary.

Record 1: ECB Violation #39554700Z — Failure to Maintain / Unsafe Condition

Hearing dateAugust 4, 2026
Hearing time8:30 AM
Source hearing status (at extract)PENDING
SeverityCLASS - 2
Violation typeConstruction
Source-listed balance$1,250
Issue dateMay 27, 2026
Served dateMay 28, 2026

What the source record says

The public description for BIN 4006772, Queens, NY states: “ACTIVE 7STORY NB W/ SWS AND SUPPORTED SCAFFOLD INSTALLED. MISSING REQUIRED DOCS ON SITE. NO LOAD IMPOSED PROVIDED FOR SUPPORTED SCAFFOLD AS PER 3314.3.4: WAS SEEN INSTALLED ATOP SWS ON EXPO2 & ATOP BALCONIES @E”

What this category usually means

This category usually concerns a building, structure, lot, wall, roof, opening, or component allegedly not maintained in safe code-compliant condition.

What a hearing on this record may have focused on

A hearing on this type of record may have focused on the condition observed by the inspector, responsibility, timing, repairs, and whether professional proof is required.

Documents and proof worth reviewing now

  • engineer or architect report
  • permits
  • inspection reports
  • repair photos
  • contractor invoices

Why this should not be ignored

Unsafe-condition records can trigger emergency repairs, reinspections, civil penalties, and transaction delays.

Cited law / infraction references
  • 2F7 BC 3301.7 (2014 CODE) FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 3

Record 2: ECB Violation #39554701K — Construction Site Safety / Public Protection

Hearing dateAugust 4, 2026
Hearing time10:30 AM
Source hearing status (at extract)PENDING
SeverityCLASS - 2
Violation typeConstruction
Source-listed balance$1,250
Issue dateMay 27, 2026
Served dateMay 28, 2026

What the source record says

The public description for BIN 4006772, Queens, NY states: “ACTIVE 7STORY NB. NOTED SUPPORTED SCAFFOLD CONTRARY TO APPROVED PLANS. SF INSTALLED ON BALCONIES @EXPO1&3 HOWEVER EXSTNG BALCONIES NOT ON PLANS (REFER PG.004 OF SF PLANS). SF @EXPO1 AT GROUND LEVEL NOT CONFORMI”

What this category usually means

This category concerns construction-site safety, public protection, watchperson requirements, guardrails, fences, sheds, sidewalk protection, or access controls.

What a hearing on this record may have focused on

The hearing may examine whether required protection was in place at the inspection time and whether the cited party controlled the work.

Documents and proof worth reviewing now

  • contractor daily reports
  • permits
  • watchperson records
  • site safety logs
  • protection photos

Why this should not be ignored

Site-safety hearings can involve large penalties because DOB treats public and worker protection as urgent.

Cited law / infraction references
  • 282 28-105.12.2 WRK DOESN'T CONFORM TO APPROV DOCS AND/OR APPROV AMENDMENTS

Questions specific to this type of OATH hearing

What should be reviewed now for this failure to maintain / unsafe condition record?

Start by confirming the current OATH/DOB status, the exact public description, law section, responsible party, correction evidence, later hearing activity, payments or judgments, and any filing or certification activity that occurred after the original source extract.

What should be reviewed now for this construction site safety / public protection record?

Start by confirming the current OATH/DOB status, the exact public description, law section, responsible party, correction evidence, later hearing activity, payments or judgments, and any filing or certification activity that occurred after the original source extract.

Why would someone search BIN 4006772, Queens, NY?

Owners, real estate professionals, contractors, buyers, attorneys, and lenders may search BIN 4006772, Queens, NY when they see an OATH hearing, open DOB/ECB record, title issue, or upcoming transaction connected to the property.

Need a current record review for BIN 4006772, Queens, NY?

The original hearing date has passed. Current agency records—not the old scheduled date—should control the next decision. Building Violation LLC can scope a paid current-status review and any follow-up work that the records support.

Request Current Status ReviewCall (866) 545-4440