What DOB is alleging at this property
This October hearing page is not just a schedule entry. The supplied DOB extract contains 4 summons records for this property identifier. The charge mix is: 2 Sidewalk Shed / Scaffold summonses; Elevator / Vertical Transportation; Façade / Exterior Wall. The hearing dates are October 22, 2026, October 29, 2026, October 8, 2026; the source issue date(s) are August 14, 2026, December 22, 2025, December 23, 2025, July 31, 2026.
Important: The discussion below identifies correction paths, hearing issues and evidence worth investigating from the summons data. It does not state that a defense will succeed. OATH decides liability from the evidence and law presented in the case.
Sidewalk Shed / Scaffold — Summons 39557359H
CLASS - 2 · Issued July 31, 2026; hearing October 8, 2026. · Hearing status: PENDING
DOB allegation in the source extract: AT TIME OF INSPECTION, OBSERVED A SIDEWALK SHED ERECTED AT 90 JOHN STREET DISPLAYING DOB SIDEWALK SHED PERMIT NO. M00957153-I1-SH WITH A EXPIRATION DATE OF 12/04/2025
Cited provision(s): 2P8
How this type of condition is typically resolved
The issue is typically whether the shed/scaffold was permitted, properly installed and maintained, and whether the equipment matched the approved filing and current safety requirements. Correction can involve permit renewal, physical modification, inspection, or removal.
Hearing issues to verify
- Was the equipment covered by an active permit on the inspection date?
- Did the installed dimensions/protection match the approved design?
- Was a cited defect already corrected before the summons was issued or served?
Evidence that may matter
- DOB NOW equipment permit and approved drawings
- Engineer/contractor inspection logs
- Dated site photographs
- Renewal or removal records
Elevator / Vertical Transportation — Summons 39200699M
CLASS - 1 · Issued August 14, 2026; hearing October 22, 2026. · Hearing status: PENDING
DOB allegation in the source extract: VF... R T S.... ELEVATOR IN BUILDING OUT OF SERVICE . UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE CREATING A HAZARDOUS CONDITION ASPER IRCNY 11-02 . REPAIR THE DEVICE AND RESTORE TO SERVICE IMMEDIA
Cited provision(s): 151 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: SERVICE EQUIPME
How this type of condition is typically resolved
Elevator charges often require licensed-elevator maintenance or repair, the required periodic inspection/test filing, an affirmation of correction where applicable, and reinspection for hazardous conditions.
Hearing issues to verify
- Does the device number/location on the summons match the building's elevator record?
- Was the cited defect repaired or the device removed from service before the inspection?
- Were the required CAT/periodic inspection filings timely and accepted?
Evidence that may matter
- Elevator device record and inspection/test reports
- Maintenance contractor logs and repair tickets
- Affirmation of Correction / reinspection result
- Photographs or controller/service records
Façade / Exterior Wall — Summons 39548286L
CLASS - 2 · Issued December 22, 2025; hearing October 29, 2026. · Hearing status: PENDING
DOB allegation in the source extract: AT TIME OF INSPECTION OF A BUILDING UNDER FACADE REPAIR I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE # 1,3 AND 4 UPON REVIEW THE DEPARTMENT RECORD IT SHOWS THAT THE SIDEWALK SHED PERMIT HAD EXPIRED SINCE 12-04
Cited provision(s): 2P8
How this type of condition is typically resolved
Exterior-wall charges usually require a competent inspection of the cited façade/appurtenance, repair of unsafe or deteriorated conditions, and—when the building is subject to FISP—the appropriate QEWI report or amended filing.
Hearing issues to verify
- Does the inspector's description match the actual exposure, floor and defect?
- Was the condition already repaired or protected before the summons date?
- Was there a current FISP/QEWI filing addressing the same condition?
Evidence that may matter
- QEWI report, FISP filing or amended report
- Close-up and elevation photographs identifying the exact defect
- Repair proposals, invoices and completion records
- Engineer/architect letter and inspection documentation
Sidewalk Shed / Scaffold — Summons 39548436H
CLASS - 2 · Issued December 23, 2025; hearing October 29, 2026. · Hearing status: PENDING
DOB allegation in the source extract: OBSERVED SUPPORTED PIPE SCAFFOLD ERECTED ON TOP OF A SIDEWALK SHED DECK WITHOUT A PARAPET WALL OR EQUIVALENT EDGE PROTECTION. NO OVERHEAD PROTECTION OR CONTROLLED ACCESS ZONE WAS PROVIDED AT THE SIDEWALK LEVEL.
Cited provision(s): 209 — BC 3301.2,27-1009(A) FAIL TO SAFEGUARD PERS/PROPERTY AFFECTED BY CONSTRUCTION OP
How this type of condition is typically resolved
The issue is typically whether the shed/scaffold was permitted, properly installed and maintained, and whether the equipment matched the approved filing and current safety requirements. Correction can involve permit renewal, physical modification, inspection, or removal.
Hearing issues to verify
- Was the equipment covered by an active permit on the inspection date?
- Did the installed dimensions/protection match the approved design?
- Was a cited defect already corrected before the summons was issued or served?
Evidence that may matter
- DOB NOW equipment permit and approved drawings
- Engineer/contractor inspection logs
- Dated site photographs
- Renewal or removal records
Case-specific next step
For this property, the first paid review should reconcile the 4 October summons records against the current OATH/DOB record, identify which alleged conditions remain open, and separate the hearing defense from the DOB correction / certification work. That prevents paying for correction work that does not address the actual charge—or appearing at OATH without the documents needed for the cited condition.