BuildingViolation.com

October 2026 NYC DOB / OATH Hearing — BIN 1022632

Manhattan property record with 11 OATH/ECB summons records in the supplied October 2026 hearing extract. Hearing dates: October 15, 2026, October 22, 2026.

Need representation for this October hearing?

We can review the summons, agency record, correction status and available evidence; define the hearing strategy; prepare the authorized submission or appearance; and coordinate the underlying violation-resolution work separately where needed. Because hearing deadlines are fixed, substantive work begins after scope, authorization and payment.

Property / Hearing Identifiers

Primary hearing issue: Elevator / Vertical Transportation

BoroughManhattan
BIN1022632
Block / Lot00997 / 0047
October Records11
Official violation location: Loading from NYC OATH public records…
Address is resolved from the OATH Hearings Division Case Status record for OATH ticket 039200103M (source ECB number 39200103M). BIN and block/lot remain shown below for verification.

October 2026 Hearing Records

OATH/ECB #HearingSeverityHearing statusBalanceAlleged conditionCode / section
39200049K
ACTIVE
October 15, 2026
10:30 AM
CLASS - 2 PENDING $625.00 CLASS 2: 1. DROP CEILING SECTION LEADING TO TOP EXIT (ESCAPE HATCH) NOT PROPERLY SECURED FROM TOP OF CAR. AS PER ASME A17.1 2.14. REMEDY: SECURE CEILING SECTION. 2. SEPARATION OF CAR DOORS AT BOTTOM WHILE CAR I 251 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER:SERVICE EQUIPMEN
39200102K
ACTIVE
October 15, 2026
10:30 AM
CLASS - 1 PENDING $2,500.00 ELECTRICAL WORK WITHOUT A PERMIT. OBSERVED ON THE GROUND FL KITCHEN ELECTRIC OVEN / FOOD WARMER INSTALLED WITH DISCONNECT SW 3/4 PIPE COMING FROM KITCHEN PANEL. CHECKED BIS / DOB NOW NO PERMIT ON FILE ALL WORK 1C9 — 27-3018(B) ELECTRICAL WORK WITHOUT A PERMIT
39200129K
ACTIVE
October 15, 2026
10:30 AM
CLASS - 1 PENDING $6,250.00 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HOLE PENETRATIONS THROUGHOUT BUILDING. PREVIOUS VIOLATING # 39156212X., REPAIR AND/REPLACE 102 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER
39193758K
ACTIVE
October 15, 2026
8:30 AM
CLASS - 1 ADMIT/IN-VIO $0.00 FAILURE TO SUBMIT A CERTIFICATE OF CORRECTION OF VIOLATION #39110398J ISSUED ON 04-01-2024 FOR WORK WITHOUT A PERMIT.(NO PERMIT ON DOB RECORD ), COMPLY WITH COMMISSIONER'S ORDER 187 — 28-201.1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER
39200100R
ACTIVE
October 15, 2026
8:30 AM
CLASS - 1 PENDING $1,600.00 UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED IN THE REAR CORRIDOR A HUNG ELECTRIC HEATER WITH A FLEX CORD PASSING THRU THE CEILING. IN 1D2 — EC 110.2(A) UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT OR WIRING IN USE
39200103M
ACTIVE
October 15, 2026
8:30 AM
CLASS - 1 PENDING $4,800.00 FAILURE TO INSTALL GROUNDING ELECTRODE CONDUCTOR. OBSERVED IN THE MAIN ELECTRICAL RM NO INSTALLATION ON ELECTRODE GROUND ROD ALSO THE MAIN HOUSE WATER GROUND CLAMP IS RUSTED AND THE WATER METER IS NOT JUMPED. A 1D9 — EC 250.64 FAIL TO INSTALL GROUNDING ELECTRODE CONDUCTOR AS PER SECTION
39200130H
ACTIVE
October 15, 2026
8:30 AM
CLASS - 2 PENDING $1,250.00 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED GARBAGE BINS OBSTRUCTING EGRESS PASSAGEWAY. LOCATED THROUGHOUT BUILDING., REPAIR AND/OR REPLACE 202 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER
39200048Z
ACTIVE
October 15, 2026
9:30 AM
CLASS - 2 PENDING $625.00 CLASS 2: 1. MAIN LINE BOX COVER CAN BE OPENED WHILE POWER IS ON, FAILING TO PROVIDE REQUIRED SECURED ACCESS. AS PER ASME A17.1 2.26. REMEDY: SECURE MAIN LINE BOX COVER TO PREVENT ACCESS UNDER POWER. 2. WATER AC 251 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER:SERVICE EQUIPMEN
39200101Z
ACTIVE
October 15, 2026
9:30 AM
CLASS - 2 PENDING $2,400.00 FAILURE TO PROTECT CONDUCTOR(S) AGAINST OVERCURRENT. OBSERVED IN BOTH ELEVATOR MACHINE RMS THAT THE OVERCURRENT PROTECTION IS INCORRECT BOTH ARE FUSED AT 100 AMP #6 AWG SHALL BE FUSED AT THE PROPER OVERCURRENT 2D9 — EC 240.4 FAILURE TO PROTECT CONDUCTOR(S) AGAINST OVERCURRENT PER EC
39200809Y
ACTIVE
October 22, 2026
8:30 AM
CLASS - 2 PENDING $1,250.00 AT THE TIME OF INSPECTION OBSERVED W HOT WATER HEATERS INSTALLED WITHOUT PRESSURE RELIEF VALVES WHICH IS CONTRARY TO CODE PC 504.6 ESTABLISHES THE REQUIREMENTS FOR DISCHARGE PIPING SERVING TEMPERATURE AND PRESS 202 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER
39200810L
ACTIVE
October 22, 2026
9:30 AM
CLASS - 2 PENDING $1,250.00 AT THE TIME OF INSPECTION OBSERVED IN THE LOBBY AREA A SINK THAT WAS INSTALLED WITH OUT A TRAP USING A WASHER MACHINE STYLE HOSE FOR DRAINAGE PC 1002.1 - PLUMBING FIXTURES AND DRAINAGE SYSTEMS SHALL BE PROPERLY 202 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER

What DOB is alleging at this property

This October hearing page is not just a schedule entry. The supplied DOB extract contains 11 summons records for this property identifier. The charge mix is: 3 Elevator / Vertical Transportation summonses; 2 Failure to Maintain summonses; Work Without a Permit; Certificate of Correction / Commissioner Order; Electrical Work / Electrical Permit; Other Building / Code Compliance; Egress / Exit Obstruction; Plumbing / Gas. The hearing dates are October 15, 2026, October 22, 2026; the source issue date(s) are August 11, 2026, August 17, 2026, June 25, 2026.

Important: The discussion below identifies correction paths, hearing issues and evidence worth investigating from the summons data. It does not state that a defense will succeed. OATH decides liability from the evidence and law presented in the case.

Elevator / Vertical Transportation — Summons 39200049K

CLASS - 2 · Issued August 11, 2026; hearing October 15, 2026. · Hearing status: PENDING

DOB allegation in the source extract: CLASS 2: 1. DROP CEILING SECTION LEADING TO TOP EXIT (ESCAPE HATCH) NOT PROPERLY SECURED FROM TOP OF CAR. AS PER ASME A17.1 2.14. REMEDY: SECURE CEILING SECTION. 2. SEPARATION OF CAR DOORS AT BOTTOM WHILE CAR I

Cited provision(s): 251 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER:SERVICE EQUIPMEN

How this type of condition is typically resolved

Elevator charges often require licensed-elevator maintenance or repair, the required periodic inspection/test filing, an affirmation of correction where applicable, and reinspection for hazardous conditions.

Hearing issues to verify

  • Does the device number/location on the summons match the building's elevator record?
  • Was the cited defect repaired or the device removed from service before the inspection?
  • Were the required CAT/periodic inspection filings timely and accepted?

Evidence that may matter

  • Elevator device record and inspection/test reports
  • Maintenance contractor logs and repair tickets
  • Affirmation of Correction / reinspection result
  • Photographs or controller/service records

Work Without a Permit — Summons 39200102K

CLASS - 1 · Issued August 11, 2026; hearing October 15, 2026. · Hearing status: PENDING

DOB allegation in the source extract: ELECTRICAL WORK WITHOUT A PERMIT. OBSERVED ON THE GROUND FL KITCHEN ELECTRIC OVEN / FOOD WARMER INSTALLED WITH DISCONNECT SW 3/4 PIPE COMING FROM KITCHEN PANEL. CHECKED BIS / DOB NOW NO PERMIT ON FILE ALL WORK

Cited provision(s): 1C9 — 27-3018(B) ELECTRICAL WORK WITHOUT A PERMIT

How this type of condition is typically resolved

The correction path usually starts by determining whether the observed work required a permit and whether the condition can legally remain. If it can remain, legalization may require plans, a filing, permit, inspections and closeout; if it cannot or the owner does not want to legalize it, restoration to a lawful condition may be required.

Hearing issues to verify

  • Did a valid permit already cover the exact work described by the inspector on the issue date?
  • Was the cited activity actually permit-required work, or was it maintenance / exempt work under the applicable facts?
  • Do the approved drawings, permit scope and inspection history match the condition the inspector described?
  • If a Stop Work Order was issued, was the work stopped and was any later work performed only after the required authorization?

Evidence that may matter

  • Permit and DOB NOW/BIS job records that predate the inspection
  • Approved plans and amendments showing the cited work
  • Dated photographs of the condition and construction stage
  • Contracts, invoices and contractor statements establishing what work was actually performed
  • Inspection / sign-off records if the work was subsequently legalized

Failure to Maintain — Summons 39200129K

CLASS - 1 · Issued August 11, 2026; hearing October 15, 2026. · Hearing status: PENDING

DOB allegation in the source extract: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HOLE PENETRATIONS THROUGHOUT BUILDING. PREVIOUS VIOLATING # 39156212X., REPAIR AND/REPLACE

Cited provision(s): 102 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER

How this type of condition is typically resolved

Failure-to-maintain charges are fact-specific. The owner should identify the exact building component or service equipment cited, repair the condition, and document the repair with evidence tied to the inspection location/date.

Hearing issues to verify

  • Does the description accurately identify the component, location and condition?
  • Was the condition already repaired or not present when the summons was issued?
  • Was another party responsible for maintenance under facts that are legally relevant to the respondent's liability?

Evidence that may matter

  • Dated before/after photographs
  • Repair invoices and contractor statements
  • Professional inspection/report when structural or technical conditions are involved
  • Maintenance logs and prior inspection records

Certificate of Correction / Commissioner Order — Summons 39193758K

CLASS - 1 · Issued June 25, 2026; hearing October 15, 2026. · Hearing status: ADMIT/IN-VIO

DOB allegation in the source extract: FAILURE TO SUBMIT A CERTIFICATE OF CORRECTION OF VIOLATION #39110398J ISSUED ON 04-01-2024 FOR WORK WITHOUT A PERMIT.(NO PERMIT ON DOB RECORD ), COMPLY WITH COMMISSIONER'S ORDER

Cited provision(s): 187 — 28-201.1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER

How this type of condition is typically resolved

This charge focuses on failure to complete or document the DOB correction process for an earlier summons. The practical task is usually to identify the underlying summons, confirm that its physical condition was actually corrected, and complete the current DOB Certificate of Correction requirements with the supporting proof and any applicable civil-penalty documentation.

Hearing issues to verify

  • Was a Certificate of Correction already submitted or approved for the underlying summons before this charge was issued?
  • Does DOB's record identify the same underlying summons number and correction deadline described in this citation?
  • Was the physical condition actually corrected, and can that correction be tied to the cited condition rather than a different job or location?

Evidence that may matter

  • DOB NOW / AEU Certificate of Correction submission or approval record
  • Before-and-after photographs tied to the cited condition
  • Permits, inspection results, contractor receipts or professional statements supporting the correction
  • Proof of applicable DOB civil-penalty payment or waiver, if required

Electrical Work / Electrical Permit — Summons 39200100R

CLASS - 1 · Issued August 11, 2026; hearing October 15, 2026. · Hearing status: PENDING

DOB allegation in the source extract: UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED IN THE REAR CORRIDOR A HUNG ELECTRIC HEATER WITH A FLEX CORD PASSING THRU THE CEILING. IN

Cited provision(s): 1D2 — EC 110.2(A) UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT OR WIRING IN USE

How this type of condition is typically resolved

Electrical charges generally require determining whether the cited installation was permitted and performed under the required licensed-electrical process, then correcting unsafe or unapproved work and obtaining any required inspection/acceptance.

Hearing issues to verify

  • Was there an active electrical application/permit covering the cited wiring or equipment?
  • Was the condition already corrected or disconnected before the inspection date?
  • Does the cited equipment/location match the permitted scope and electrical inspection record?

Evidence that may matter

  • Electrical permit/application and inspection records
  • Licensed electrician invoice, letter or work order
  • Photographs of wiring/equipment before and after correction
  • Testing, certification or utility documentation where relevant

Other Building / Code Compliance — Summons 39200103M

CLASS - 1 · Issued August 11, 2026; hearing October 15, 2026. · Hearing status: PENDING

DOB allegation in the source extract: FAILURE TO INSTALL GROUNDING ELECTRODE CONDUCTOR. OBSERVED IN THE MAIN ELECTRICAL RM NO INSTALLATION ON ELECTRODE GROUND ROD ALSO THE MAIN HOUSE WATER GROUND CLAMP IS RUSTED AND THE WATER METER IS NOT JUMPED. A

Cited provision(s): 1D9 — EC 250.64 FAIL TO INSTALL GROUNDING ELECTRODE CONDUCTOR AS PER SECTION

How this type of condition is typically resolved

The first step is to read the inspector's narrative together with every cited code section and determine exactly what act, condition or missing filing DOB alleges. The correction and hearing strategy should then be built around that specific charge rather than a generic violation-removal checklist.

Hearing issues to verify

  • Does the summons identify the correct property, respondent, date and observed condition?
  • Do agency records support or contradict the inspector's description?
  • Was the condition corrected, permitted or otherwise resolved before the hearing?

Evidence that may matter

  • Official DOB/OATH property and summons records
  • Dated photographs and videos
  • Permits, approved plans and inspection results
  • Contracts, receipts, professional letters or witness statements tied to the cited condition

Egress / Exit Obstruction — Summons 39200130H

CLASS - 2 · Issued August 11, 2026; hearing October 15, 2026. · Hearing status: PENDING

DOB allegation in the source extract: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED GARBAGE BINS OBSTRUCTING EGRESS PASSAGEWAY. LOCATED THROUGHOUT BUILDING., REPAIR AND/OR REPLACE

Cited provision(s): 202 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER

How this type of condition is typically resolved

Egress charges are generally corrected by removing the obstruction or restoring the required exit width/path and then documenting that the means of egress is clear and code compliant.

Hearing issues to verify

  • Was the cited passageway actually required egress for the affected occupancy?
  • Did the alleged obstruction exist when the inspector observed it?
  • Was the condition immediately removed and can the timing be documented?

Evidence that may matter

  • Dated photographs showing the exit path
  • Approved floor/egress plans
  • Building or security logs
  • Statements or work records documenting removal of stored items/obstructions

Elevator / Vertical Transportation — Summons 39200048Z

CLASS - 2 · Issued August 11, 2026; hearing October 15, 2026. · Hearing status: PENDING

DOB allegation in the source extract: CLASS 2: 1. MAIN LINE BOX COVER CAN BE OPENED WHILE POWER IS ON, FAILING TO PROVIDE REQUIRED SECURED ACCESS. AS PER ASME A17.1 2.26. REMEDY: SECURE MAIN LINE BOX COVER TO PREVENT ACCESS UNDER POWER. 2. WATER AC

Cited provision(s): 251 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER:SERVICE EQUIPMEN

How this type of condition is typically resolved

Elevator charges often require licensed-elevator maintenance or repair, the required periodic inspection/test filing, an affirmation of correction where applicable, and reinspection for hazardous conditions.

Hearing issues to verify

  • Does the device number/location on the summons match the building's elevator record?
  • Was the cited defect repaired or the device removed from service before the inspection?
  • Were the required CAT/periodic inspection filings timely and accepted?

Evidence that may matter

  • Elevator device record and inspection/test reports
  • Maintenance contractor logs and repair tickets
  • Affirmation of Correction / reinspection result
  • Photographs or controller/service records

Elevator / Vertical Transportation — Summons 39200101Z

CLASS - 2 · Issued August 11, 2026; hearing October 15, 2026. · Hearing status: PENDING

DOB allegation in the source extract: FAILURE TO PROTECT CONDUCTOR(S) AGAINST OVERCURRENT. OBSERVED IN BOTH ELEVATOR MACHINE RMS THAT THE OVERCURRENT PROTECTION IS INCORRECT BOTH ARE FUSED AT 100 AMP #6 AWG SHALL BE FUSED AT THE PROPER OVERCURRENT

Cited provision(s): 2D9 — EC 240.4 FAILURE TO PROTECT CONDUCTOR(S) AGAINST OVERCURRENT PER EC

How this type of condition is typically resolved

Elevator charges often require licensed-elevator maintenance or repair, the required periodic inspection/test filing, an affirmation of correction where applicable, and reinspection for hazardous conditions.

Hearing issues to verify

  • Does the device number/location on the summons match the building's elevator record?
  • Was the cited defect repaired or the device removed from service before the inspection?
  • Were the required CAT/periodic inspection filings timely and accepted?

Evidence that may matter

  • Elevator device record and inspection/test reports
  • Maintenance contractor logs and repair tickets
  • Affirmation of Correction / reinspection result
  • Photographs or controller/service records

Failure to Maintain — Summons 39200809Y

CLASS - 2 · Issued August 17, 2026; hearing October 22, 2026. · Hearing status: PENDING

DOB allegation in the source extract: AT THE TIME OF INSPECTION OBSERVED W HOT WATER HEATERS INSTALLED WITHOUT PRESSURE RELIEF VALVES WHICH IS CONTRARY TO CODE PC 504.6 ESTABLISHES THE REQUIREMENTS FOR DISCHARGE PIPING SERVING TEMPERATURE AND PRESS

Cited provision(s): 202 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER

How this type of condition is typically resolved

Failure-to-maintain charges are fact-specific. The owner should identify the exact building component or service equipment cited, repair the condition, and document the repair with evidence tied to the inspection location/date.

Hearing issues to verify

  • Does the description accurately identify the component, location and condition?
  • Was the condition already repaired or not present when the summons was issued?
  • Was another party responsible for maintenance under facts that are legally relevant to the respondent's liability?

Evidence that may matter

  • Dated before/after photographs
  • Repair invoices and contractor statements
  • Professional inspection/report when structural or technical conditions are involved
  • Maintenance logs and prior inspection records

Plumbing / Gas — Summons 39200810L

CLASS - 2 · Issued August 17, 2026; hearing October 22, 2026. · Hearing status: PENDING

DOB allegation in the source extract: AT THE TIME OF INSPECTION OBSERVED IN THE LOBBY AREA A SINK THAT WAS INSTALLED WITH OUT A TRAP USING A WASHER MACHINE STYLE HOSE FOR DRAINAGE PC 1002.1 - PLUMBING FIXTURES AND DRAINAGE SYSTEMS SHALL BE PROPERLY

Cited provision(s): 202 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER

How this type of condition is typically resolved

Plumbing/gas matters typically require determining whether the work was permitted and performed by the required licensed trade, correcting unsafe or unapproved conditions, and completing inspections/sign-off.

Hearing issues to verify

  • Was there a valid plumbing/gas filing covering the cited scope?
  • Did the condition predate the respondent's work or ownership?
  • Was the cited installation already disconnected or corrected?

Evidence that may matter

  • Licensed Master Plumber permit / filing records
  • Pressure-test / inspection / utility records
  • Invoices and plumber statements
  • Photographs showing the installation and correction

Case-specific next step

For this property, the first paid review should reconcile the 11 October summons records against the current OATH/DOB record, identify which alleged conditions remain open, and separate the hearing defense from the DOB correction / certification work. That prevents paying for correction work that does not address the actual charge—or appearing at OATH without the documents needed for the cited condition.

Submit These Summonses for Review

What to do before the hearing

1. Verify the summons

Confirm the scheduled date, respondent, violation location, charges and current OATH status.

2. Preserve evidence

Gather permits, photographs, contracts, inspection records, professional letters and proof of correction that actually relate to the cited condition.

3. Separate hearing from correction

A hearing result and physical/agency correction are not always the same task. Plan both tracks where required.

Official Hearing Record

Verify the current hearing status and violation location in the NYC OATH Hearings Division Case Status data before relying on any public directory.

NYC OATH Case Status Data →

OATH evidence and DOB correction records

OATH advises respondents to bring or submit the evidence needed to prove their case, including legal or official records, photographs, documents and witnesses. For a DOB Certificate of Correction, DOB may require supporting material such as photographs, receipts, permits and inspection results in addition to the required correction information and applicable civil-penalty documentation.