What DOB is alleging at this property
This October hearing page is not just a schedule entry. The supplied DOB extract contains 3 summons records for this property identifier. The charge mix is: 2 Elevator / Vertical Transportation summonses; Failure to Maintain. The hearing dates are October 1, 2026, October 22, 2026; the source issue date(s) are August 13, 2026, July 28, 2026.
Important: The discussion below identifies correction paths, hearing issues and evidence worth investigating from the summons data. It does not state that a defense will succeed. OATH decides liability from the evidence and law presented in the case.
Failure to Maintain — Summons 39197915N
CLASS - 2 · Issued July 28, 2026; hearing October 1, 2026. · Hearing status: PENDING
DOB allegation in the source extract: AT THE TIME OF INSPECTION, THE CORNICE STONE AT THE RIGHT CORNER OF EXPOSURE #1, LOCATED ALONG THE ROOF FACING FREDERICK DOUGLASS BOULEVARD, WAS OBSERVED TO BE DETERIORATED AND IN A STATE OF DISREPAIR, REPAIR A
Cited provision(s): 202 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER
How this type of condition is typically resolved
Failure-to-maintain charges are fact-specific. The owner should identify the exact building component or service equipment cited, repair the condition, and document the repair with evidence tied to the inspection location/date.
Hearing issues to verify
- Does the description accurately identify the component, location and condition?
- Was the condition already repaired or not present when the summons was issued?
- Was another party responsible for maintenance under facts that are legally relevant to the respondent's liability?
Evidence that may matter
- Dated before/after photographs
- Repair invoices and contractor statements
- Professional inspection/report when structural or technical conditions are involved
- Maintenance logs and prior inspection records
Elevator / Vertical Transportation — Summons 39200537J
CLASS - 1 · Issued August 13, 2026; hearing October 22, 2026. · Hearing status: PENDING
DOB allegation in the source extract: UPON INSPECTION, THE BUILDING'S ONLY ELEVATOR WAS FOUND OUT OF SERVICE AND REPORTEDLY HAS REMAINED INOPERATIVE FOR AN EXTENDED PERIOD, DEPRIVING THE BUILDING'S 49 DWELLING UNITS OF ELEVATOR SERVICE TO FLOORS 1
Cited provision(s): 151 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: SERVICE EQUIPME
How this type of condition is typically resolved
Elevator charges often require licensed-elevator maintenance or repair, the required periodic inspection/test filing, an affirmation of correction where applicable, and reinspection for hazardous conditions.
Hearing issues to verify
- Does the device number/location on the summons match the building's elevator record?
- Was the cited defect repaired or the device removed from service before the inspection?
- Were the required CAT/periodic inspection filings timely and accepted?
Evidence that may matter
- Elevator device record and inspection/test reports
- Maintenance contractor logs and repair tickets
- Affirmation of Correction / reinspection result
- Photographs or controller/service records
Elevator / Vertical Transportation — Summons 39200536H
CLASS - 1 · Issued August 13, 2026; hearing October 22, 2026. · Hearing status: PENDING
DOB allegation in the source extract: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. WHEELCHAIR LIFT FOUND OUT OF SERVICE, CREATING A HAZARDOUS CONDITION AND FAILING TO MAINTAIN REQUIRED SERVICE EQUIPMENT IN GOOD WORKING CONDITION PER AC 28
Cited provision(s): 151 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: SERVICE EQUIPME
How this type of condition is typically resolved
Elevator charges often require licensed-elevator maintenance or repair, the required periodic inspection/test filing, an affirmation of correction where applicable, and reinspection for hazardous conditions.
Hearing issues to verify
- Does the device number/location on the summons match the building's elevator record?
- Was the cited defect repaired or the device removed from service before the inspection?
- Were the required CAT/periodic inspection filings timely and accepted?
Evidence that may matter
- Elevator device record and inspection/test reports
- Maintenance contractor logs and repair tickets
- Affirmation of Correction / reinspection result
- Photographs or controller/service records
Case-specific next step
For this property, the first paid review should reconcile the 3 October summons records against the current OATH/DOB record, identify which alleged conditions remain open, and separate the hearing defense from the DOB correction / certification work. That prevents paying for correction work that does not address the actual charge—or appearing at OATH without the documents needed for the cited condition.
Submit These Summonses for Review