What DOB is alleging at this property
This October hearing page is not just a schedule entry. The supplied DOB extract contains 2 summons records for this property identifier. The charge mix is: 2 Sidewalk Shed / Scaffold summonses. The hearing date is October 15, 2026; the source issue date(s) are July 21, 2025.
Important: The discussion below identifies correction paths, hearing issues and evidence worth investigating from the summons data. It does not state that a defense will succeed. OATH decides liability from the evidence and law presented in the case.
Sidewalk Shed / Scaffold — Summons 39542613M
CLASS - 2 · Issued July 21, 2025; hearing October 15, 2026. · Hearing status: PENDING
DOB allegation in the source extract: AT TIME OF INSPECTION OF A 6-STORY BUILDING, I NO SIGN OF CONSTRUCTION ACTIVITIES SIDEWALK SHED ERECTED EXP#1AND4.DURING MY INSPECTION I NOTICED SIDEWALK SHED HAS NO INFORMATION PANEL.THIS CREATE A HAZARDOUS SI
Cited provision(s): 217 — BC 3301.9,27-10009(C) FAIL TO PROVIDE/POST SIGN(S) AT JB SITE PURSUANT TO SUBSEC
How this type of condition is typically resolved
The issue is typically whether the shed/scaffold was permitted, properly installed and maintained, and whether the equipment matched the approved filing and current safety requirements. Correction can involve permit renewal, physical modification, inspection, or removal.
Hearing issues to verify
- Was the equipment covered by an active permit on the inspection date?
- Did the installed dimensions/protection match the approved design?
- Was a cited defect already corrected before the summons was issued or served?
Evidence that may matter
- DOB NOW equipment permit and approved drawings
- Engineer/contractor inspection logs
- Dated site photographs
- Renewal or removal records
Sidewalk Shed / Scaffold — Summons 39542615X
CLASS - 2 · Issued July 21, 2025; hearing October 15, 2026. · Hearing status: PENDING
DOB allegation in the source extract: AT TIME OF MY INSPECTION OF A 6-STORY BUILDING, I OBSERVED A SIDEWALK SHED ERECTED AT EXP#1 AND 4 AND MAINTAINED AS PER CODE 1-SIDEWALK SHED NOT FULLY PLANK EXP#1 ALLOWING DEBRIS FALLING FROM ABOVE CREATE UNSAF
Cited provision(s): 223 — BC 3307.6,27-1021 SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS
How this type of condition is typically resolved
The issue is typically whether the shed/scaffold was permitted, properly installed and maintained, and whether the equipment matched the approved filing and current safety requirements. Correction can involve permit renewal, physical modification, inspection, or removal.
Hearing issues to verify
- Was the equipment covered by an active permit on the inspection date?
- Did the installed dimensions/protection match the approved design?
- Was a cited defect already corrected before the summons was issued or served?
Evidence that may matter
- DOB NOW equipment permit and approved drawings
- Engineer/contractor inspection logs
- Dated site photographs
- Renewal or removal records
Case-specific next step
For this property, the first paid review should reconcile the 2 October summons records against the current OATH/DOB record, identify which alleged conditions remain open, and separate the hearing defense from the DOB correction / certification work. That prevents paying for correction work that does not address the actual charge—or appearing at OATH without the documents needed for the cited condition.