Bronx property record with 4 OATH/ECB summons records in the supplied October 2026 hearing extract. Hearing dates: October 2, 2026, October 30, 2026.

Need representation for this October hearing?

We can review the summons, agency record, correction status and available evidence; define the hearing strategy; prepare the authorized submission or appearance; and coordinate the underlying violation-resolution work separately where needed. Because hearing deadlines are fixed, substantive work begins after scope, authorization and payment.

Property / Hearing Identifiers

Primary hearing issue: Egress / Exit Obstruction

BoroughBronx
BIN2000594
Block / Lot02301 / 0028
October Records4
Official violation location: Loading from NYC OATH public records…
Address is resolved from the OATH Hearings Division Case Status record for OATH ticket 035734167M (source ECB number 35734167M). BIN and block/lot remain shown below for verification.

October 2026 Hearing Records

OATH/ECB #HearingSeverityHearing statusBalanceAlleged conditionCode / section
35734167M
ACTIVE
October 2, 2026
8:30 AM
CLASS - 1 PENDING $6,250.00 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED: MAIN ENTRANCE/EXIT DOOR WAS NOT READILY OPENABLE FROM THE EGRESS SIDE. LEVEL HARDWARE FAILED TO FULLY RETRACT MAKING IT DIFFICULT TO OPEN OR CLOSE CORRECT 127 — 27-369,BC 1020.2 FAIL TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY
35734168Y
ACTIVE
October 2, 2026
8:30 AM
CLASS - 1 PENDING $6,250.00 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT ROOF LEVEL, INTERIOR BULKHEAD HAS WATER PENETRATIONS CREATING WATER DAMAGE TO CEILING. AT THE TIME OF INSPECTION, ALSO AT THE MAIN ENTRANCE CRACK 102 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER
39200714L
ACTIVE
October 30, 2026
8:30 AM
CLASS - 1 PENDING $1,600.00 I OBSERVED UNSAFE UNSUITABLE ELECTRICAL CONDITIONS, OPEN BREAKER PANELS AND MAIN LINE BOX WITHOUT COVERS SUBJECT TO ELECTROCUTION OR POTENTIAL FIRE., COMPLY WITH EC; FIX ALL CONDITIONS AS PER NEC AND NYC AMENDM 1D2 — EC 110.2(A) UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT OR WIRING IN USE
39200715N
ACTIVE
October 30, 2026
9:30 AM
CLASS - 1 PENDING $2,500.00 I OBSERVED REPLACEMENT OF LINE SIDE RACEWAY DUE TO ELECTRICAL SHORT AND 200 AMP SERVICE PANEL AND METER ENCLOSURE INSTALLED WITHOUT AND ELECTRICAL PERMIT ON FILE., OBTAIN PERMIT; OBTAIN ELECTRICAL PANEL 1C9 — 27-3018(B) ELECTRICAL WORK WITHOUT A PERMIT

What DOB is alleging at this property

This October hearing page is not just a schedule entry. The supplied DOB extract contains 4 summons records for this property identifier. The charge mix is: Egress / Exit Obstruction; Failure to Maintain; Electrical Work / Electrical Permit; Work Without a Permit. The hearing dates are October 2, 2026, October 30, 2026; the source issue date(s) are August 15, 2026, July 1, 2026.

Important: The discussion below identifies correction paths, hearing issues and evidence worth investigating from the summons data. It does not state that a defense will succeed. OATH decides liability from the evidence and law presented in the case.

Egress / Exit Obstruction — Summons 35734167M

CLASS - 1 · Issued July 1, 2026; hearing October 2, 2026. · Hearing status: PENDING

DOB allegation in the source extract: FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED: MAIN ENTRANCE/EXIT DOOR WAS NOT READILY OPENABLE FROM THE EGRESS SIDE. LEVEL HARDWARE FAILED TO FULLY RETRACT MAKING IT DIFFICULT TO OPEN OR CLOSE CORRECT

Cited provision(s): 127 — 27-369,BC 1020.2 FAIL TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY

How this type of condition is typically resolved

Egress charges are generally corrected by removing the obstruction or restoring the required exit width/path and then documenting that the means of egress is clear and code compliant.

Hearing issues to verify

  • Was the cited passageway actually required egress for the affected occupancy?
  • Did the alleged obstruction exist when the inspector observed it?
  • Was the condition immediately removed and can the timing be documented?

Evidence that may matter

  • Dated photographs showing the exit path
  • Approved floor/egress plans
  • Building or security logs
  • Statements or work records documenting removal of stored items/obstructions

Failure to Maintain — Summons 35734168Y

CLASS - 1 · Issued July 1, 2026; hearing October 2, 2026. · Hearing status: PENDING

DOB allegation in the source extract: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT ROOF LEVEL, INTERIOR BULKHEAD HAS WATER PENETRATIONS CREATING WATER DAMAGE TO CEILING. AT THE TIME OF INSPECTION, ALSO AT THE MAIN ENTRANCE CRACK

Cited provision(s): 102 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER

How this type of condition is typically resolved

Failure-to-maintain charges are fact-specific. The owner should identify the exact building component or service equipment cited, repair the condition, and document the repair with evidence tied to the inspection location/date.

Hearing issues to verify

  • Does the description accurately identify the component, location and condition?
  • Was the condition already repaired or not present when the summons was issued?
  • Was another party responsible for maintenance under facts that are legally relevant to the respondent's liability?

Evidence that may matter

  • Dated before/after photographs
  • Repair invoices and contractor statements
  • Professional inspection/report when structural or technical conditions are involved
  • Maintenance logs and prior inspection records

Electrical Work / Electrical Permit — Summons 39200714L

CLASS - 1 · Issued August 15, 2026; hearing October 30, 2026. · Hearing status: PENDING

DOB allegation in the source extract: I OBSERVED UNSAFE UNSUITABLE ELECTRICAL CONDITIONS, OPEN BREAKER PANELS AND MAIN LINE BOX WITHOUT COVERS SUBJECT TO ELECTROCUTION OR POTENTIAL FIRE., COMPLY WITH EC; FIX ALL CONDITIONS AS PER NEC AND NYC AMENDM

Cited provision(s): 1D2 — EC 110.2(A) UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT OR WIRING IN USE

How this type of condition is typically resolved

Electrical charges generally require determining whether the cited installation was permitted and performed under the required licensed-electrical process, then correcting unsafe or unapproved work and obtaining any required inspection/acceptance.

Hearing issues to verify

  • Was there an active electrical application/permit covering the cited wiring or equipment?
  • Was the condition already corrected or disconnected before the inspection date?
  • Does the cited equipment/location match the permitted scope and electrical inspection record?

Evidence that may matter

  • Electrical permit/application and inspection records
  • Licensed electrician invoice, letter or work order
  • Photographs of wiring/equipment before and after correction
  • Testing, certification or utility documentation where relevant

Work Without a Permit — Summons 39200715N

CLASS - 1 · Issued August 15, 2026; hearing October 30, 2026. · Hearing status: PENDING

DOB allegation in the source extract: I OBSERVED REPLACEMENT OF LINE SIDE RACEWAY DUE TO ELECTRICAL SHORT AND 200 AMP SERVICE PANEL AND METER ENCLOSURE INSTALLED WITHOUT AND ELECTRICAL PERMIT ON FILE., OBTAIN PERMIT; OBTAIN ELECTRICAL PANEL

Cited provision(s): 1C9 — 27-3018(B) ELECTRICAL WORK WITHOUT A PERMIT

How this type of condition is typically resolved

The correction path usually starts by determining whether the observed work required a permit and whether the condition can legally remain. If it can remain, legalization may require plans, a filing, permit, inspections and closeout; if it cannot or the owner does not want to legalize it, restoration to a lawful condition may be required.

Hearing issues to verify

  • Did a valid permit already cover the exact work described by the inspector on the issue date?
  • Was the cited activity actually permit-required work, or was it maintenance / exempt work under the applicable facts?
  • Do the approved drawings, permit scope and inspection history match the condition the inspector described?
  • If a Stop Work Order was issued, was the work stopped and was any later work performed only after the required authorization?

Evidence that may matter

  • Permit and DOB NOW/BIS job records that predate the inspection
  • Approved plans and amendments showing the cited work
  • Dated photographs of the condition and construction stage
  • Contracts, invoices and contractor statements establishing what work was actually performed
  • Inspection / sign-off records if the work was subsequently legalized

Case-specific next step

For this property, the first paid review should reconcile the 4 October summons records against the current OATH/DOB record, identify which alleged conditions remain open, and separate the hearing defense from the DOB correction / certification work. That prevents paying for correction work that does not address the actual charge—or appearing at OATH without the documents needed for the cited condition.

Submit These Summonses for Review

What to do before the hearing

1. Verify the summons

Confirm the scheduled date, respondent, violation location, charges and current OATH status.

2. Preserve evidence

Gather permits, photographs, contracts, inspection records, professional letters and proof of correction that actually relate to the cited condition.

3. Separate hearing from correction

A hearing result and physical/agency correction are not always the same task. Plan both tracks where required.

Official Hearing Record

Verify the current hearing status and violation location in the NYC OATH Hearings Division Case Status data before relying on any public directory.

NYC OATH Case Status Data →

OATH evidence and DOB correction records

OATH advises respondents to bring or submit the evidence needed to prove their case, including legal or official records, photographs, documents and witnesses. For a DOB Certificate of Correction, DOB may require supporting material such as photographs, receipts, permits and inspection results in addition to the required correction information and applicable civil-penalty documentation.