What DOB is alleging at this property
This October hearing page is not just a schedule entry. The supplied DOB extract contains 2 summons records for this property identifier. The charge mix is: 2 Elevator / Vertical Transportation summonses. The hearing dates are October 2, 2026, October 30, 2026; the source issue date(s) are August 13, 2026, July 20, 2026.
Important: The discussion below identifies correction paths, hearing issues and evidence worth investigating from the summons data. It does not state that a defense will succeed. OATH decides liability from the evidence and law presented in the case.
Elevator / Vertical Transportation — Summons 39196724X
CLASS - 2 · Issued July 20, 2026; hearing October 2, 2026. · Hearing status: PENDING
DOB allegation in the source extract: CLAS 2 ITEMS: ELEVATOR FAILED TO RESPOND TO A REGISTERED CAR CALL AND/OR HALL CALL FOR THE 6TH FLOOR. ELEVATOR IS NOT OPERATING AS INTENDED AND SHALL BE REPAIRED TO RESTORE SERVICE TO ALL DESIGNATED LANDINGS IN
Cited provision(s): 251 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER:SERVICE EQUIPMEN
How this type of condition is typically resolved
Elevator charges often require licensed-elevator maintenance or repair, the required periodic inspection/test filing, an affirmation of correction where applicable, and reinspection for hazardous conditions.
Hearing issues to verify
- Does the device number/location on the summons match the building's elevator record?
- Was the cited defect repaired or the device removed from service before the inspection?
- Were the required CAT/periodic inspection filings timely and accepted?
Evidence that may matter
- Elevator device record and inspection/test reports
- Maintenance contractor logs and repair tickets
- Affirmation of Correction / reinspection result
- Photographs or controller/service records
Elevator / Vertical Transportation — Summons 39200527X
CLASS - 2 · Issued August 13, 2026; hearing October 30, 2026. · Hearing status: PENDING
DOB allegation in the source extract: CLASS 2 ITEMS: HOISTWAY LANDING DOORS AT THE BASEMENT, 4TH FLOOR, AND 6TH FLOOR WERE OBSERVED NOT PROPERLY CLOSING. DOORS SHALL BE REPAIRED/ADJUSTED TO PROPERLY CLOSE AND LATCH. EMERGENCY ALARM BELL IN ELEVATOR
Cited provision(s): 251 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER:SERVICE EQUIPMEN
How this type of condition is typically resolved
Elevator charges often require licensed-elevator maintenance or repair, the required periodic inspection/test filing, an affirmation of correction where applicable, and reinspection for hazardous conditions.
Hearing issues to verify
- Does the device number/location on the summons match the building's elevator record?
- Was the cited defect repaired or the device removed from service before the inspection?
- Were the required CAT/periodic inspection filings timely and accepted?
Evidence that may matter
- Elevator device record and inspection/test reports
- Maintenance contractor logs and repair tickets
- Affirmation of Correction / reinspection result
- Photographs or controller/service records
Case-specific next step
For this property, the first paid review should reconcile the 2 October summons records against the current OATH/DOB record, identify which alleged conditions remain open, and separate the hearing defense from the DOB correction / certification work. That prevents paying for correction work that does not address the actual charge—or appearing at OATH without the documents needed for the cited condition.
Submit These Summonses for Review