BuildingViolation.com

October 2026 NYC DOB / OATH Hearing — BIN 2022077

Bronx property record with 5 OATH/ECB summons records in the supplied October 2026 hearing extract. Hearing date: October 16, 2026.

Need representation for this October hearing?

We can review the summons, agency record, correction status and available evidence; define the hearing strategy; prepare the authorized submission or appearance; and coordinate the underlying violation-resolution work separately where needed. Because hearing deadlines are fixed, substantive work begins after scope, authorization and payment.

Property / Hearing Identifiers

Primary hearing issue: Work Without a Permit

BoroughBronx
BIN2022077
Block / Lot03596 / 0017
October Records5
Official violation location: Loading from NYC OATH public records…
Address is resolved from the OATH Hearings Division Case Status record for OATH ticket 039200208Z (source ECB number 39200208Z). BIN and block/lot remain shown below for verification.

October 2026 Hearing Records

OATH/ECB #HearingSeverityHearing statusBalanceAlleged conditionCode / section
35721955K
ACTIVE
October 16, 2026
10:30 AM
CLASS - 1 PENDING $12,500.00 FAILURE TO MAINTAIN IN CODE-COMPLIANT MANNER. ATOI, OBSERVED PORTIONS OF THE CEILING/CEILING FINISHES HAVE COLLAPSED ARE IN A DETERIORATED CONDITION, WITH EXTENSIVE LOOSE AND FALLEN CEILING MATERIALS, INSULATIO 102 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER
39200208Z
ACTIVE
October 16, 2026
10:30 AM
CLASS - 1 PENDING $2,500.00 ATOI CONSTRUCTION/ALTERATION WORK, INCLUDING REMOVAL AND/OR REPLACEMENT OF CEILING AND INTERIOR BUILDING ELEMENTS LIKE WALL PARTITIONS, KITCHEN AND TOILET WAS OBSERVED CONSTRUCTED WITHOUT A VALID DOB PERMIT, OB 101 — 28-105.1 WORK WITHOUT A PERMIT
39200209K
ACTIVE
October 16, 2026
8:30 AM
CLASS - 1 PENDING $2,500.00 AT THE TIME OF INSPECTION, ELECTRICAL WORK / AC UNITS, CONDUITS FOR LIGHTS WERE INSTALLED WITHOUT THE REQUIRED ELECTRICAL PERMIT AND/OR APPROVALS. THE INSTALLATION WAS PERFORMED WITHOUT AUTHORIZATION FROM THE A 1C9 — 27-3018(B) ELECTRICAL WORK WITHOUT A PERMIT
39200207R
ACTIVE
October 16, 2026
9:30 AM
CLASS - 1 PENDING $2,500.00 ATOI THE PREMISES IS BEING OCCUPIED/USED FOR A PURPOSE DIFFERENT FROM THE USE OR OCCUPANCY PERMITTED BY THE CURRENT CERTIFICATE OF OCCUPANCY, WITHOUT OBTAINING THE REQUIRED APPROVAL AND/OR AMENDED CERTIFICATE O 108 — 28-118.3 ALTER/CHANGE BLDG OCCUP W/O VALID C/O PER 28-118.3.1,28-118.3.2
39200210H
ACTIVE
October 16, 2026
9:30 AM
CLASS - 2 PENDING $1,250.00 ATOI OBSERVED PLUMBING WORK, INCLUDING INSTALLATION, ALTERATION AND/OR MODIFICATION OF PLUMBING PIPING AND FIXTURES, BEING PERFORMED WITHOUT A VALID PERMIT. VIOLATION OF PC 102.3; ADMINISTRATIVE CODE 27-902, RE 266 — 28-301.1 FAIL TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER RE:INSTALLATION/MAI

What DOB is alleging at this property

This October hearing page is not just a schedule entry. The supplied DOB extract contains 5 summons records for this property identifier. The charge mix is: 2 Work Without a Permit summonses; Failure to Maintain; Illegal Occupancy / Conversion; Plumbing / Gas. The hearing date is October 16, 2026; the source issue date(s) are August 11, 2026.

Important: The discussion below identifies correction paths, hearing issues and evidence worth investigating from the summons data. It does not state that a defense will succeed. OATH decides liability from the evidence and law presented in the case.

Failure to Maintain — Summons 35721955K

CLASS - 1 · Issued August 11, 2026; hearing October 16, 2026. · Hearing status: PENDING

DOB allegation in the source extract: FAILURE TO MAINTAIN IN CODE-COMPLIANT MANNER. ATOI, OBSERVED PORTIONS OF THE CEILING/CEILING FINISHES HAVE COLLAPSED ARE IN A DETERIORATED CONDITION, WITH EXTENSIVE LOOSE AND FALLEN CEILING MATERIALS, INSULATIO

Cited provision(s): 102 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER

How this type of condition is typically resolved

Failure-to-maintain charges are fact-specific. The owner should identify the exact building component or service equipment cited, repair the condition, and document the repair with evidence tied to the inspection location/date.

Hearing issues to verify

  • Does the description accurately identify the component, location and condition?
  • Was the condition already repaired or not present when the summons was issued?
  • Was another party responsible for maintenance under facts that are legally relevant to the respondent's liability?

Evidence that may matter

  • Dated before/after photographs
  • Repair invoices and contractor statements
  • Professional inspection/report when structural or technical conditions are involved
  • Maintenance logs and prior inspection records

Work Without a Permit — Summons 39200208Z

CLASS - 1 · Issued August 11, 2026; hearing October 16, 2026. · Hearing status: PENDING

DOB allegation in the source extract: ATOI CONSTRUCTION/ALTERATION WORK, INCLUDING REMOVAL AND/OR REPLACEMENT OF CEILING AND INTERIOR BUILDING ELEMENTS LIKE WALL PARTITIONS, KITCHEN AND TOILET WAS OBSERVED CONSTRUCTED WITHOUT A VALID DOB PERMIT, OB

Cited provision(s): 101 — 28-105.1 WORK WITHOUT A PERMIT

How this type of condition is typically resolved

The correction path usually starts by determining whether the observed work required a permit and whether the condition can legally remain. If it can remain, legalization may require plans, a filing, permit, inspections and closeout; if it cannot or the owner does not want to legalize it, restoration to a lawful condition may be required.

Hearing issues to verify

  • Did a valid permit already cover the exact work described by the inspector on the issue date?
  • Was the cited activity actually permit-required work, or was it maintenance / exempt work under the applicable facts?
  • Do the approved drawings, permit scope and inspection history match the condition the inspector described?
  • If a Stop Work Order was issued, was the work stopped and was any later work performed only after the required authorization?

Evidence that may matter

  • Permit and DOB NOW/BIS job records that predate the inspection
  • Approved plans and amendments showing the cited work
  • Dated photographs of the condition and construction stage
  • Contracts, invoices and contractor statements establishing what work was actually performed
  • Inspection / sign-off records if the work was subsequently legalized

Work Without a Permit — Summons 39200209K

CLASS - 1 · Issued August 11, 2026; hearing October 16, 2026. · Hearing status: PENDING

DOB allegation in the source extract: AT THE TIME OF INSPECTION, ELECTRICAL WORK / AC UNITS, CONDUITS FOR LIGHTS WERE INSTALLED WITHOUT THE REQUIRED ELECTRICAL PERMIT AND/OR APPROVALS. THE INSTALLATION WAS PERFORMED WITHOUT AUTHORIZATION FROM THE A

Cited provision(s): 1C9 — 27-3018(B) ELECTRICAL WORK WITHOUT A PERMIT

How this type of condition is typically resolved

The correction path usually starts by determining whether the observed work required a permit and whether the condition can legally remain. If it can remain, legalization may require plans, a filing, permit, inspections and closeout; if it cannot or the owner does not want to legalize it, restoration to a lawful condition may be required.

Hearing issues to verify

  • Did a valid permit already cover the exact work described by the inspector on the issue date?
  • Was the cited activity actually permit-required work, or was it maintenance / exempt work under the applicable facts?
  • Do the approved drawings, permit scope and inspection history match the condition the inspector described?
  • If a Stop Work Order was issued, was the work stopped and was any later work performed only after the required authorization?

Evidence that may matter

  • Permit and DOB NOW/BIS job records that predate the inspection
  • Approved plans and amendments showing the cited work
  • Dated photographs of the condition and construction stage
  • Contracts, invoices and contractor statements establishing what work was actually performed
  • Inspection / sign-off records if the work was subsequently legalized

Illegal Occupancy / Conversion — Summons 39200207R

CLASS - 1 · Issued August 11, 2026; hearing October 16, 2026. · Hearing status: PENDING

DOB allegation in the source extract: ATOI THE PREMISES IS BEING OCCUPIED/USED FOR A PURPOSE DIFFERENT FROM THE USE OR OCCUPANCY PERMITTED BY THE CURRENT CERTIFICATE OF OCCUPANCY, WITHOUT OBTAINING THE REQUIRED APPROVAL AND/OR AMENDED CERTIFICATE O

Cited provision(s): 108 — 28-118.3 ALTER/CHANGE BLDG OCCUP W/O VALID C/O PER 28-118.3.1,28-118.3.2

How this type of condition is typically resolved

The key question is whether the observed occupancy or layout matches the lawful use of the premises. Resolution may require restoring the prior lawful layout/use or, when legally feasible, filing plans and obtaining approvals to legalize the condition.

Hearing issues to verify

  • What use and number of dwelling/occupancy units are shown by the Certificate of Occupancy, Schedule of Occupancy or other lawful-use records?
  • Did the inspector accurately identify how the space was being used on the cited date?
  • Was the cited space actually occupied as alleged, or were the observed beds, kitchens, locks or partitions consistent with another lawful use?
  • Is there an approved filing or historical record supporting the present use?

Evidence that may matter

  • Certificate of Occupancy / Schedule of Occupancy and approved plans
  • Historic occupancy records, permits and prior approved layouts
  • Dated photographs and floor plans
  • Leases, tenant records or sworn statements concerning actual use
  • Permits/inspection records if the condition was legalized or restored

Plumbing / Gas — Summons 39200210H

CLASS - 2 · Issued August 11, 2026; hearing October 16, 2026. · Hearing status: PENDING

DOB allegation in the source extract: ATOI OBSERVED PLUMBING WORK, INCLUDING INSTALLATION, ALTERATION AND/OR MODIFICATION OF PLUMBING PIPING AND FIXTURES, BEING PERFORMED WITHOUT A VALID PERMIT. VIOLATION OF PC 102.3; ADMINISTRATIVE CODE 27-902, RE

Cited provision(s): 266 — 28-301.1 FAIL TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER RE:INSTALLATION/MAI

How this type of condition is typically resolved

Plumbing/gas matters typically require determining whether the work was permitted and performed by the required licensed trade, correcting unsafe or unapproved conditions, and completing inspections/sign-off.

Hearing issues to verify

  • Was there a valid plumbing/gas filing covering the cited scope?
  • Did the condition predate the respondent's work or ownership?
  • Was the cited installation already disconnected or corrected?

Evidence that may matter

  • Licensed Master Plumber permit / filing records
  • Pressure-test / inspection / utility records
  • Invoices and plumber statements
  • Photographs showing the installation and correction

Case-specific next step

For this property, the first paid review should reconcile the 5 October summons records against the current OATH/DOB record, identify which alleged conditions remain open, and separate the hearing defense from the DOB correction / certification work. That prevents paying for correction work that does not address the actual charge—or appearing at OATH without the documents needed for the cited condition.

Submit These Summonses for Review

What to do before the hearing

1. Verify the summons

Confirm the scheduled date, respondent, violation location, charges and current OATH status.

2. Preserve evidence

Gather permits, photographs, contracts, inspection records, professional letters and proof of correction that actually relate to the cited condition.

3. Separate hearing from correction

A hearing result and physical/agency correction are not always the same task. Plan both tracks where required.

Official Hearing Record

Verify the current hearing status and violation location in the NYC OATH Hearings Division Case Status data before relying on any public directory.

NYC OATH Case Status Data →

OATH evidence and DOB correction records

OATH advises respondents to bring or submit the evidence needed to prove their case, including legal or official records, photographs, documents and witnesses. For a DOB Certificate of Correction, DOB may require supporting material such as photographs, receipts, permits and inspection results in addition to the required correction information and applicable civil-penalty documentation.