BuildingViolation.com

October 2026 NYC DOB / OATH Hearing — BIN 3036454

Brooklyn property record with 2 OATH/ECB summons records in the supplied October 2026 hearing extract. Hearing date: October 28, 2026.

Need representation for this October hearing?

We can review the summons, agency record, correction status and available evidence; define the hearing strategy; prepare the authorized submission or appearance; and coordinate the underlying violation-resolution work separately where needed. Because hearing deadlines are fixed, substantive work begins after scope, authorization and payment.

Property / Hearing Identifiers

Primary hearing issue: Sidewalk Shed / Scaffold

BoroughBrooklyn
BIN3036454
Block / Lot01371 / 0056
October Records2
Official violation location: Loading from NYC OATH public records…
Address is resolved from the OATH Hearings Division Case Status record for OATH ticket 035721906Y (source ECB number 35721906Y). BIN and block/lot remain shown below for verification.

October 2026 Hearing Records

OATH/ECB #HearingSeverityHearing statusBalanceAlleged conditionCode / section
35721905M
ACTIVE
October 28, 2026
10:30 AM
CLASS - 2 PENDING $6,250.00 CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT. NOTED APPROX. 25' OF SIDEWALK SHED @ 12FT HEIGHT WITH FENCE ON A SITE WHERE PERMIT HAS BEEN ALLOWED TO EXPIRE, ALLOWING EXPIRED PERMIT HAS CREATED A CONDITION WHER 207 — BC 105.8.2 TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT
35721906Y
ACTIVE
October 28, 2026
10:30 AM
CLASS - 1 PENDING $12,500.00 FAILURE TO MAINTAIN BUILDING LOT. NOTED ON A STALLED SITE WHERE PERMITS HAVE LAPSED THAT OWNER HAS FAILED TO MAINTAIN FENCE AND SHED NEGLECTHAS CAUSED A SECTION OF PARAPET FROM SHED TO COLLAPSE TO PUBLIC WALKWA 102 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER

What DOB is alleging at this property

This October hearing page is not just a schedule entry. The supplied DOB extract contains 2 summons records for this property identifier. The charge mix is: Sidewalk Shed / Scaffold; Failure to Maintain. The hearing date is October 28, 2026; the source issue date(s) are August 17, 2026.

Important: The discussion below identifies correction paths, hearing issues and evidence worth investigating from the summons data. It does not state that a defense will succeed. OATH decides liability from the evidence and law presented in the case.

Sidewalk Shed / Scaffold — Summons 35721905M

CLASS - 2 · Issued August 17, 2026; hearing October 28, 2026. · Hearing status: PENDING

DOB allegation in the source extract: CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT. NOTED APPROX. 25' OF SIDEWALK SHED @ 12FT HEIGHT WITH FENCE ON A SITE WHERE PERMIT HAS BEEN ALLOWED TO EXPIRE, ALLOWING EXPIRED PERMIT HAS CREATED A CONDITION WHER

Cited provision(s): 207 — BC 105.8.2 TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT

How this type of condition is typically resolved

The issue is typically whether the shed/scaffold was permitted, properly installed and maintained, and whether the equipment matched the approved filing and current safety requirements. Correction can involve permit renewal, physical modification, inspection, or removal.

Hearing issues to verify

  • Was the equipment covered by an active permit on the inspection date?
  • Did the installed dimensions/protection match the approved design?
  • Was a cited defect already corrected before the summons was issued or served?

Evidence that may matter

  • DOB NOW equipment permit and approved drawings
  • Engineer/contractor inspection logs
  • Dated site photographs
  • Renewal or removal records

Failure to Maintain — Summons 35721906Y

CLASS - 1 · Issued August 17, 2026; hearing October 28, 2026. · Hearing status: PENDING

DOB allegation in the source extract: FAILURE TO MAINTAIN BUILDING LOT. NOTED ON A STALLED SITE WHERE PERMITS HAVE LAPSED THAT OWNER HAS FAILED TO MAINTAIN FENCE AND SHED NEGLECTHAS CAUSED A SECTION OF PARAPET FROM SHED TO COLLAPSE TO PUBLIC WALKWA

Cited provision(s): 102 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER

How this type of condition is typically resolved

Failure-to-maintain charges are fact-specific. The owner should identify the exact building component or service equipment cited, repair the condition, and document the repair with evidence tied to the inspection location/date.

Hearing issues to verify

  • Does the description accurately identify the component, location and condition?
  • Was the condition already repaired or not present when the summons was issued?
  • Was another party responsible for maintenance under facts that are legally relevant to the respondent's liability?

Evidence that may matter

  • Dated before/after photographs
  • Repair invoices and contractor statements
  • Professional inspection/report when structural or technical conditions are involved
  • Maintenance logs and prior inspection records

Case-specific next step

For this property, the first paid review should reconcile the 2 October summons records against the current OATH/DOB record, identify which alleged conditions remain open, and separate the hearing defense from the DOB correction / certification work. That prevents paying for correction work that does not address the actual charge—or appearing at OATH without the documents needed for the cited condition.

Submit These Summonses for Review

What to do before the hearing

1. Verify the summons

Confirm the scheduled date, respondent, violation location, charges and current OATH status.

2. Preserve evidence

Gather permits, photographs, contracts, inspection records, professional letters and proof of correction that actually relate to the cited condition.

3. Separate hearing from correction

A hearing result and physical/agency correction are not always the same task. Plan both tracks where required.

Official Hearing Record

Verify the current hearing status and violation location in the NYC OATH Hearings Division Case Status data before relying on any public directory.

NYC OATH Case Status Data →

OATH evidence and DOB correction records

OATH advises respondents to bring or submit the evidence needed to prove their case, including legal or official records, photographs, documents and witnesses. For a DOB Certificate of Correction, DOB may require supporting material such as photographs, receipts, permits and inspection results in addition to the required correction information and applicable civil-penalty documentation.