October 2026 NYC DOB / OATH Hearing — BIN 3043203

Brooklyn property record with 3 OATH/ECB summons records in the supplied October 2026 hearing extract. Hearing dates: October 14, 2026, October 21, 2026.

Need representation for this October hearing?

We can review the summons, agency record, correction status and available evidence; define the hearing strategy; prepare the authorized submission or appearance; and coordinate the underlying violation-resolution work separately where needed. Because hearing deadlines are fixed, substantive work begins after scope, authorization and payment.

Property / Hearing Identifiers

Primary hearing issue: Elevator / Vertical Transportation

BoroughBrooklyn
BIN3043203
Block / Lot01600 / 7501
October Records3
Official violation location: Loading from NYC OATH public records…
Address is resolved from the OATH Hearings Division Case Status record for OATH ticket 039199000Y (source ECB number 39199000Y). BIN and block/lot remain shown below for verification.

October 2026 Hearing Records

OATH/ECB #HearingSeverityHearing statusBalanceAlleged conditionCode / section
39199000Y
ACTIVE
October 14, 2026
10:30 AM
CLASS - 2 PENDING $625.00 CLASS 2: ONE IN-CAR LIGHT INOPERATIVE, REDUCING REQUIRED PASSENGER ILLUMINATION. AS PER ASME A17.1 8.6. REMEDY: REPAIR/REPLACE. EXCESSIVE GAP AT THE BOTTOM OF THE CAR DOOR IN THE CLOSED POSITION, CREATING A NON 251 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER:SERVICE EQUIPMEN
39199001X
ACTIVE
October 14, 2026
8:30 AM
CLASS - 2 PENDING $625.00 CLASS 2: CAT 5 TEST TAG MISSING. AS PER ASME A17.1 8.6. REMEDY: PROVIDE CURRENT CAT 5 TEST TAG. BUILDING EQUIPMENT STORED IN THE ELEVATOR CONTROL ROOM, CREATING AN UNSAFE AND NON-COMPLIANT WORK ENVIRONMENT. AS 251 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER:SERVICE EQUIPMEN
39199731H
ACTIVE
October 21, 2026
8:30 AM
CLASS - 2 PENDING $1,250.00 ATOI OBSERVED PVC PIPE BEING USED ON WASTE J\LINE FOR SINK IN FOOD PREP AREA. PER PC 701.9 PLASTIC PIPE. PLASTIC PIPING AND FITTINGS SHALL NOT BE USED., REPAIR AND/OR REPLACE 202 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER

What DOB is alleging at this property

This October hearing page is not just a schedule entry. The supplied DOB extract contains 3 summons records for this property identifier. The charge mix is: 2 Elevator / Vertical Transportation summonses; Failure to Maintain. The hearing dates are October 14, 2026, October 21, 2026; the source issue date(s) are August 4, 2026, August 7, 2026.

Important: The discussion below identifies correction paths, hearing issues and evidence worth investigating from the summons data. It does not state that a defense will succeed. OATH decides liability from the evidence and law presented in the case.

Elevator / Vertical Transportation — Summons 39199000Y

CLASS - 2 · Issued August 4, 2026; hearing October 14, 2026. · Hearing status: PENDING

DOB allegation in the source extract: CLASS 2: ONE IN-CAR LIGHT INOPERATIVE, REDUCING REQUIRED PASSENGER ILLUMINATION. AS PER ASME A17.1 8.6. REMEDY: REPAIR/REPLACE. EXCESSIVE GAP AT THE BOTTOM OF THE CAR DOOR IN THE CLOSED POSITION, CREATING A NON

Cited provision(s): 251 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER:SERVICE EQUIPMEN

How this type of condition is typically resolved

Elevator charges often require licensed-elevator maintenance or repair, the required periodic inspection/test filing, an affirmation of correction where applicable, and reinspection for hazardous conditions.

Hearing issues to verify

  • Does the device number/location on the summons match the building's elevator record?
  • Was the cited defect repaired or the device removed from service before the inspection?
  • Were the required CAT/periodic inspection filings timely and accepted?

Evidence that may matter

  • Elevator device record and inspection/test reports
  • Maintenance contractor logs and repair tickets
  • Affirmation of Correction / reinspection result
  • Photographs or controller/service records

Elevator / Vertical Transportation — Summons 39199001X

CLASS - 2 · Issued August 4, 2026; hearing October 14, 2026. · Hearing status: PENDING

DOB allegation in the source extract: CLASS 2: CAT 5 TEST TAG MISSING. AS PER ASME A17.1 8.6. REMEDY: PROVIDE CURRENT CAT 5 TEST TAG. BUILDING EQUIPMENT STORED IN THE ELEVATOR CONTROL ROOM, CREATING AN UNSAFE AND NON-COMPLIANT WORK ENVIRONMENT. AS

Cited provision(s): 251 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER:SERVICE EQUIPMEN

How this type of condition is typically resolved

Elevator charges often require licensed-elevator maintenance or repair, the required periodic inspection/test filing, an affirmation of correction where applicable, and reinspection for hazardous conditions.

Hearing issues to verify

  • Does the device number/location on the summons match the building's elevator record?
  • Was the cited defect repaired or the device removed from service before the inspection?
  • Were the required CAT/periodic inspection filings timely and accepted?

Evidence that may matter

  • Elevator device record and inspection/test reports
  • Maintenance contractor logs and repair tickets
  • Affirmation of Correction / reinspection result
  • Photographs or controller/service records

Failure to Maintain — Summons 39199731H

CLASS - 2 · Issued August 7, 2026; hearing October 21, 2026. · Hearing status: PENDING

DOB allegation in the source extract: ATOI OBSERVED PVC PIPE BEING USED ON WASTE J\LINE FOR SINK IN FOOD PREP AREA. PER PC 701.9 PLASTIC PIPE. PLASTIC PIPING AND FITTINGS SHALL NOT BE USED., REPAIR AND/OR REPLACE

Cited provision(s): 202 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER

How this type of condition is typically resolved

Failure-to-maintain charges are fact-specific. The owner should identify the exact building component or service equipment cited, repair the condition, and document the repair with evidence tied to the inspection location/date.

Hearing issues to verify

  • Does the description accurately identify the component, location and condition?
  • Was the condition already repaired or not present when the summons was issued?
  • Was another party responsible for maintenance under facts that are legally relevant to the respondent's liability?

Evidence that may matter

  • Dated before/after photographs
  • Repair invoices and contractor statements
  • Professional inspection/report when structural or technical conditions are involved
  • Maintenance logs and prior inspection records

Case-specific next step

For this property, the first paid review should reconcile the 3 October summons records against the current OATH/DOB record, identify which alleged conditions remain open, and separate the hearing defense from the DOB correction / certification work. That prevents paying for correction work that does not address the actual charge—or appearing at OATH without the documents needed for the cited condition.

Submit These Summonses for Review

What to do before the hearing

1. Verify the summons

Confirm the scheduled date, respondent, violation location, charges and current OATH status.

2. Preserve evidence

Gather permits, photographs, contracts, inspection records, professional letters and proof of correction that actually relate to the cited condition.

3. Separate hearing from correction

A hearing result and physical/agency correction are not always the same task. Plan both tracks where required.

Official Hearing Record

Verify the current hearing status and violation location in the NYC OATH Hearings Division Case Status data before relying on any public directory.

NYC OATH Case Status Data →

OATH evidence and DOB correction records

OATH advises respondents to bring or submit the evidence needed to prove their case, including legal or official records, photographs, documents and witnesses. For a DOB Certificate of Correction, DOB may require supporting material such as photographs, receipts, permits and inspection results in addition to the required correction information and applicable civil-penalty documentation.