BuildingViolation.com

October 2026 NYC DOB / OATH Hearing — BIN 3058265

Brooklyn property record with 3 OATH/ECB summons records in the supplied October 2026 hearing extract. Hearing date: October 7, 2026.

Need representation for this October hearing?

We can review the summons, agency record, correction status and available evidence; define the hearing strategy; prepare the authorized submission or appearance; and coordinate the underlying violation-resolution work separately where needed. Because hearing deadlines are fixed, substantive work begins after scope, authorization and payment.

Property / Hearing Identifiers

Primary hearing issue: Sidewalk Shed / Scaffold

BoroughBrooklyn
BIN3058265
Block / Lot02072 / 0001
October Records3
Official violation location: Loading from NYC OATH public records…
Address is resolved from the OATH Hearings Division Case Status record for OATH ticket 039557424P (source ECB number 39557424P). BIN and block/lot remain shown below for verification.

October 2026 Hearing Records

OATH/ECB #HearingSeverityHearing statusBalanceAlleged conditionCode / section
39557424P
ACTIVE
October 7, 2026
10:30 AM
CLASS - 2 PENDING $1,250.00 AT TIME OF INSPECTION SITE FAILED TO PROVIDE/ MAINTAIN REQUIRED ON SITE DOCUMENTATION. SPECIFICALLY, NO COMPLETION LETTER FOR THE PIPE SCAFFOLD INSTALLED ALONG EXP 1,3,& 4 WAS PROVIDED CONTRARY TO BC 3301.7. A 2F7 — BC 3301.7 (2014 CODE) FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 3
39557425R
ACTIVE
October 7, 2026
8:30 AM
CLASS - 1 PENDING $5,000.00 OBSERVED JOB SITE UTILIZING A MAKESHIFT STAIRCASE PROVIDING ACCESS BETWEEN THE CELLAR THREW 1ST FLOOR. UPON REQUEST SITE REP FAILED TO PRODUCE ENGINEERED DESIGN DRAWINGS FOR MAKESHIFT STAIRCASE. FAILURE TO PROV 1P7
39557427K
ACTIVE
October 7, 2026
9:30 AM
CLASS - 2 PENDING $1,250.00 AT TIME OF INSPECTION AFTER REVIEW OF DOB SYSTEM, NO ACTIVE PERMITS WERE OBSERVED FOR BOTH TEMPORARY EQUIPMENT (SUPPORTED SCAFFOLD AND SIDE WALK SHED) PERMITS WERE FOUND TO EXPIRE ON 7/27/26. COMPLY WITH BC 105 207 — BC 105.8.2 TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT

What DOB is alleging at this property

This October hearing page is not just a schedule entry. The supplied DOB extract contains 3 summons records for this property identifier. The charge mix is: 2 Sidewalk Shed / Scaffold summonses; Sign / Awning / Advertising. The hearing date is October 7, 2026; the source issue date(s) are August 3, 2026.

Important: The discussion below identifies correction paths, hearing issues and evidence worth investigating from the summons data. It does not state that a defense will succeed. OATH decides liability from the evidence and law presented in the case.

Sidewalk Shed / Scaffold — Summons 39557424P

CLASS - 2 · Issued August 3, 2026; hearing October 7, 2026. · Hearing status: PENDING

DOB allegation in the source extract: AT TIME OF INSPECTION SITE FAILED TO PROVIDE/ MAINTAIN REQUIRED ON SITE DOCUMENTATION. SPECIFICALLY, NO COMPLETION LETTER FOR THE PIPE SCAFFOLD INSTALLED ALONG EXP 1,3,& 4 WAS PROVIDED CONTRARY TO BC 3301.7. A

Cited provision(s): 2F7 — BC 3301.7 (2014 CODE) FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 3

How this type of condition is typically resolved

The issue is typically whether the shed/scaffold was permitted, properly installed and maintained, and whether the equipment matched the approved filing and current safety requirements. Correction can involve permit renewal, physical modification, inspection, or removal.

Hearing issues to verify

  • Was the equipment covered by an active permit on the inspection date?
  • Did the installed dimensions/protection match the approved design?
  • Was a cited defect already corrected before the summons was issued or served?

Evidence that may matter

  • DOB NOW equipment permit and approved drawings
  • Engineer/contractor inspection logs
  • Dated site photographs
  • Renewal or removal records

Sign / Awning / Advertising — Summons 39557425R

CLASS - 1 · Issued August 3, 2026; hearing October 7, 2026. · Hearing status: PENDING

DOB allegation in the source extract: OBSERVED JOB SITE UTILIZING A MAKESHIFT STAIRCASE PROVIDING ACCESS BETWEEN THE CELLAR THREW 1ST FLOOR. UPON REQUEST SITE REP FAILED TO PRODUCE ENGINEERED DESIGN DRAWINGS FOR MAKESHIFT STAIRCASE. FAILURE TO PROV

Cited provision(s): 1P7

How this type of condition is typically resolved

Sign-related charges usually require confirming zoning/permit requirements, dimensions, illumination and placement, followed by permit/legalization or removal/modification.

Hearing issues to verify

  • Was the sign/awning exempt from a permit or already covered by an approved filing?
  • Were the dimensions/location described by the inspector accurate?
  • Was the sign removed or modified before the summons date or hearing?

Evidence that may matter

  • Sign permit / zoning documents
  • Measured photographs and drawings
  • Removal or modification invoice
  • Prior approvals and storefront plans

Sidewalk Shed / Scaffold — Summons 39557427K

CLASS - 2 · Issued August 3, 2026; hearing October 7, 2026. · Hearing status: PENDING

DOB allegation in the source extract: AT TIME OF INSPECTION AFTER REVIEW OF DOB SYSTEM, NO ACTIVE PERMITS WERE OBSERVED FOR BOTH TEMPORARY EQUIPMENT (SUPPORTED SCAFFOLD AND SIDE WALK SHED) PERMITS WERE FOUND TO EXPIRE ON 7/27/26. COMPLY WITH BC 105

Cited provision(s): 207 — BC 105.8.2 TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT

How this type of condition is typically resolved

The issue is typically whether the shed/scaffold was permitted, properly installed and maintained, and whether the equipment matched the approved filing and current safety requirements. Correction can involve permit renewal, physical modification, inspection, or removal.

Hearing issues to verify

  • Was the equipment covered by an active permit on the inspection date?
  • Did the installed dimensions/protection match the approved design?
  • Was a cited defect already corrected before the summons was issued or served?

Evidence that may matter

  • DOB NOW equipment permit and approved drawings
  • Engineer/contractor inspection logs
  • Dated site photographs
  • Renewal or removal records

Case-specific next step

For this property, the first paid review should reconcile the 3 October summons records against the current OATH/DOB record, identify which alleged conditions remain open, and separate the hearing defense from the DOB correction / certification work. That prevents paying for correction work that does not address the actual charge—or appearing at OATH without the documents needed for the cited condition.

Submit These Summonses for Review

What to do before the hearing

1. Verify the summons

Confirm the scheduled date, respondent, violation location, charges and current OATH status.

2. Preserve evidence

Gather permits, photographs, contracts, inspection records, professional letters and proof of correction that actually relate to the cited condition.

3. Separate hearing from correction

A hearing result and physical/agency correction are not always the same task. Plan both tracks where required.

Official Hearing Record

Verify the current hearing status and violation location in the NYC OATH Hearings Division Case Status data before relying on any public directory.

NYC OATH Case Status Data →

OATH evidence and DOB correction records

OATH advises respondents to bring or submit the evidence needed to prove their case, including legal or official records, photographs, documents and witnesses. For a DOB Certificate of Correction, DOB may require supporting material such as photographs, receipts, permits and inspection results in addition to the required correction information and applicable civil-penalty documentation.