October 2026 NYC DOB / OATH Hearing — BIN 3117131

Brooklyn property record with 6 OATH/ECB summons records in the supplied October 2026 hearing extract. Hearing dates: October 5, 2026, October 7, 2026, October 13, 2026, October 14, 2026.

Need representation for this October hearing?

We can review the summons, agency record, correction status and available evidence; define the hearing strategy; prepare the authorized submission or appearance; and coordinate the underlying violation-resolution work separately where needed. Because hearing deadlines are fixed, substantive work begins after scope, authorization and payment.

Property / Hearing Identifiers

Primary hearing issue: Façade / Exterior Wall

BoroughBrooklyn
BIN3117131
Block / Lot05100 / 0068
October Records6
Official violation location: Loading from NYC OATH public records…
Address is resolved from the OATH Hearings Division Case Status record for OATH ticket 039141927H (source ECB number 39141927H). BIN and block/lot remain shown below for verification.

October 2026 Hearing Records

OATH/ECB #HearingSeverityHearing statusBalanceAlleged conditionCode / section
35718253Z
ACTIVE
October 5, 2026
9:00 AM
CLASS - 1 DEFAULT $25,000.00 FAILURE TO MAINTAIN BUILDING FACADE AND APPURTENANCES. OBSERVED DAMAGED MISSING MORTAR JOINTS CRACKED STONE WORK AND SEVERLY CORRODED FIRE ESCAPES ON EXPOSURE 1 IN MULTIPLE LOCATIONS. ALSO SPALLING BRICK WORK/D 104 — 28-302.1 FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES
39556842N
ACTIVE
October 7, 2026
8:30 AM
CLASS - 2 PENDING $1,250.00 AT THE TIME OF MY INSPECTION OF A 6 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1, UPON REVIEW OF THE DEPARTMENT RECORD IT REVEAL THAT THE SIDEWALK SHED PERMIT HAS BEING EXPIRED FROM 05-01-20 2P8
39141912P
ACTIVE
October 13, 2026
9:00 AM
CLASS - 1 DEFAULT $12,500.00 OBS @EXPOS:#1,2&3&4 @ MAIN ENTRANCE WALL BULGING OUT/ SPALLING CONCRETE THROUGHOUT FACADE,& MASONRY MISSING MORTAR DEFACE BRICKS DAMAGED,CRACKED,SPALLED.MORTAR JOINTS DETERIORATED DAMAGED CHIMNEY,CRACKED STONE 102 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER
39141927H
ACTIVE
October 13, 2026
9:00 AM
CLASS - 1 DEFAULT $12,500.00 OBS STRUCT WORK @FIRE ESCAPE THROUGHOUT PREMISES, ASPER SUPER OF THE BUILD WHO INFORMED ME ALL WORK IS FULLY COMPLETED ON FIRE ESCAPES REMOVAL LANDING STAIRS RUNGS, PLATFORMS CONNECT IT LADDERS STAIRS GRATINGS 101 — 28-105.1 WORK WITHOUT A PERMIT
39199125H
ACTIVE
October 14, 2026
10:30 AM
CLASS - 1 PENDING $3,125.00 1) THE IN-BOARD MOTOR-BEARING IS WORN AND NEEDS TO BE REPLACED (8.11.2.1.2). 2) THE BRAKE TAG AND THE CAT-1 TAG IS EXPIRED/MISSING (8.11.1.6). 3) THERE ARE PIPES IN THE MOTOR-ROOM THAT MAY BE COVER WITH ASBESTO 151 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: SERVICE EQUIPME
39199124X
ACTIVE
October 14, 2026
9:30 AM
CLASS - 1 PENDING $3,125.00 1) THE CAR DOES NOT HAVE UNDER CAR LIGHTING (8.11.2.1.3). 2) THE PIT IS DIRTY (8.11.2.1.3) 3) THE MOTOR WIRES HAVE DAMAGE INSULATION (RAT DAMAGE) (8.11.2.1.2). 4) THE MOTOR-ROOM FLOOR IS DAMAGED. 5) THE DRIVE S 151 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: SERVICE EQUIPME

What DOB is alleging at this property

This October hearing page is not just a schedule entry. The supplied DOB extract contains 6 summons records for this property identifier. The charge mix is: 2 Façade / Exterior Wall summonses; 2 Elevator / Vertical Transportation summonses; Sidewalk Shed / Scaffold; Work Without a Permit. The hearing dates are October 13, 2026, October 14, 2026, October 5, 2026, October 7, 2026; the source issue date(s) are August 4, 2026, July 21, 2026, July 29, 2025, March 17, 2025.

Important: The discussion below identifies correction paths, hearing issues and evidence worth investigating from the summons data. It does not state that a defense will succeed. OATH decides liability from the evidence and law presented in the case.

Façade / Exterior Wall — Summons 35718253Z

CLASS - 1 · Issued July 29, 2025; hearing October 5, 2026. · Hearing status: DEFAULT

DOB allegation in the source extract: FAILURE TO MAINTAIN BUILDING FACADE AND APPURTENANCES. OBSERVED DAMAGED MISSING MORTAR JOINTS CRACKED STONE WORK AND SEVERLY CORRODED FIRE ESCAPES ON EXPOSURE 1 IN MULTIPLE LOCATIONS. ALSO SPALLING BRICK WORK/D

Cited provision(s): 104 — 28-302.1 FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES

How this type of condition is typically resolved

Exterior-wall charges usually require a competent inspection of the cited façade/appurtenance, repair of unsafe or deteriorated conditions, and—when the building is subject to FISP—the appropriate QEWI report or amended filing.

Hearing issues to verify

  • Does the inspector's description match the actual exposure, floor and defect?
  • Was the condition already repaired or protected before the summons date?
  • Was there a current FISP/QEWI filing addressing the same condition?

Evidence that may matter

  • QEWI report, FISP filing or amended report
  • Close-up and elevation photographs identifying the exact defect
  • Repair proposals, invoices and completion records
  • Engineer/architect letter and inspection documentation

Sidewalk Shed / Scaffold — Summons 39556842N

CLASS - 2 · Issued July 21, 2026; hearing October 7, 2026. · Hearing status: PENDING

DOB allegation in the source extract: AT THE TIME OF MY INSPECTION OF A 6 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1, UPON REVIEW OF THE DEPARTMENT RECORD IT REVEAL THAT THE SIDEWALK SHED PERMIT HAS BEING EXPIRED FROM 05-01-20

Cited provision(s): 2P8

How this type of condition is typically resolved

The issue is typically whether the shed/scaffold was permitted, properly installed and maintained, and whether the equipment matched the approved filing and current safety requirements. Correction can involve permit renewal, physical modification, inspection, or removal.

Hearing issues to verify

  • Was the equipment covered by an active permit on the inspection date?
  • Did the installed dimensions/protection match the approved design?
  • Was a cited defect already corrected before the summons was issued or served?

Evidence that may matter

  • DOB NOW equipment permit and approved drawings
  • Engineer/contractor inspection logs
  • Dated site photographs
  • Renewal or removal records

Façade / Exterior Wall — Summons 39141912P

CLASS - 1 · Issued March 17, 2025; hearing October 13, 2026. · Hearing status: DEFAULT

DOB allegation in the source extract: OBS @EXPOS:#1,2&3&4 @ MAIN ENTRANCE WALL BULGING OUT/ SPALLING CONCRETE THROUGHOUT FACADE,& MASONRY MISSING MORTAR DEFACE BRICKS DAMAGED,CRACKED,SPALLED.MORTAR JOINTS DETERIORATED DAMAGED CHIMNEY,CRACKED STONE

Cited provision(s): 102 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER

How this type of condition is typically resolved

Exterior-wall charges usually require a competent inspection of the cited façade/appurtenance, repair of unsafe or deteriorated conditions, and—when the building is subject to FISP—the appropriate QEWI report or amended filing.

Hearing issues to verify

  • Does the inspector's description match the actual exposure, floor and defect?
  • Was the condition already repaired or protected before the summons date?
  • Was there a current FISP/QEWI filing addressing the same condition?

Evidence that may matter

  • QEWI report, FISP filing or amended report
  • Close-up and elevation photographs identifying the exact defect
  • Repair proposals, invoices and completion records
  • Engineer/architect letter and inspection documentation

Work Without a Permit — Summons 39141927H

CLASS - 1 · Issued March 17, 2025; hearing October 13, 2026. · Hearing status: DEFAULT

DOB allegation in the source extract: OBS STRUCT WORK @FIRE ESCAPE THROUGHOUT PREMISES, ASPER SUPER OF THE BUILD WHO INFORMED ME ALL WORK IS FULLY COMPLETED ON FIRE ESCAPES REMOVAL LANDING STAIRS RUNGS, PLATFORMS CONNECT IT LADDERS STAIRS GRATINGS

Cited provision(s): 101 — 28-105.1 WORK WITHOUT A PERMIT

How this type of condition is typically resolved

The correction path usually starts by determining whether the observed work required a permit and whether the condition can legally remain. If it can remain, legalization may require plans, a filing, permit, inspections and closeout; if it cannot or the owner does not want to legalize it, restoration to a lawful condition may be required.

Hearing issues to verify

  • Did a valid permit already cover the exact work described by the inspector on the issue date?
  • Was the cited activity actually permit-required work, or was it maintenance / exempt work under the applicable facts?
  • Do the approved drawings, permit scope and inspection history match the condition the inspector described?
  • If a Stop Work Order was issued, was the work stopped and was any later work performed only after the required authorization?

Evidence that may matter

  • Permit and DOB NOW/BIS job records that predate the inspection
  • Approved plans and amendments showing the cited work
  • Dated photographs of the condition and construction stage
  • Contracts, invoices and contractor statements establishing what work was actually performed
  • Inspection / sign-off records if the work was subsequently legalized

Elevator / Vertical Transportation — Summons 39199125H

CLASS - 1 · Issued August 4, 2026; hearing October 14, 2026. · Hearing status: PENDING

DOB allegation in the source extract: 1) THE IN-BOARD MOTOR-BEARING IS WORN AND NEEDS TO BE REPLACED (8.11.2.1.2). 2) THE BRAKE TAG AND THE CAT-1 TAG IS EXPIRED/MISSING (8.11.1.6). 3) THERE ARE PIPES IN THE MOTOR-ROOM THAT MAY BE COVER WITH ASBESTO

Cited provision(s): 151 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: SERVICE EQUIPME

How this type of condition is typically resolved

Elevator charges often require licensed-elevator maintenance or repair, the required periodic inspection/test filing, an affirmation of correction where applicable, and reinspection for hazardous conditions.

Hearing issues to verify

  • Does the device number/location on the summons match the building's elevator record?
  • Was the cited defect repaired or the device removed from service before the inspection?
  • Were the required CAT/periodic inspection filings timely and accepted?

Evidence that may matter

  • Elevator device record and inspection/test reports
  • Maintenance contractor logs and repair tickets
  • Affirmation of Correction / reinspection result
  • Photographs or controller/service records

Elevator / Vertical Transportation — Summons 39199124X

CLASS - 1 · Issued August 4, 2026; hearing October 14, 2026. · Hearing status: PENDING

DOB allegation in the source extract: 1) THE CAR DOES NOT HAVE UNDER CAR LIGHTING (8.11.2.1.3). 2) THE PIT IS DIRTY (8.11.2.1.3) 3) THE MOTOR WIRES HAVE DAMAGE INSULATION (RAT DAMAGE) (8.11.2.1.2). 4) THE MOTOR-ROOM FLOOR IS DAMAGED. 5) THE DRIVE S

Cited provision(s): 151 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: SERVICE EQUIPME

How this type of condition is typically resolved

Elevator charges often require licensed-elevator maintenance or repair, the required periodic inspection/test filing, an affirmation of correction where applicable, and reinspection for hazardous conditions.

Hearing issues to verify

  • Does the device number/location on the summons match the building's elevator record?
  • Was the cited defect repaired or the device removed from service before the inspection?
  • Were the required CAT/periodic inspection filings timely and accepted?

Evidence that may matter

  • Elevator device record and inspection/test reports
  • Maintenance contractor logs and repair tickets
  • Affirmation of Correction / reinspection result
  • Photographs or controller/service records

Case-specific next step

For this property, the first paid review should reconcile the 6 October summons records against the current OATH/DOB record, identify which alleged conditions remain open, and separate the hearing defense from the DOB correction / certification work. That prevents paying for correction work that does not address the actual charge—or appearing at OATH without the documents needed for the cited condition.

Submit These Summonses for Review

What to do before the hearing

1. Verify the summons

Confirm the scheduled date, respondent, violation location, charges and current OATH status.

2. Preserve evidence

Gather permits, photographs, contracts, inspection records, professional letters and proof of correction that actually relate to the cited condition.

3. Separate hearing from correction

A hearing result and physical/agency correction are not always the same task. Plan both tracks where required.

Official Hearing Record

Verify the current hearing status and violation location in the NYC OATH Hearings Division Case Status data before relying on any public directory.

NYC OATH Case Status Data →

OATH evidence and DOB correction records

OATH advises respondents to bring or submit the evidence needed to prove their case, including legal or official records, photographs, documents and witnesses. For a DOB Certificate of Correction, DOB may require supporting material such as photographs, receipts, permits and inspection results in addition to the required correction information and applicable civil-penalty documentation.