What DOB is alleging at this property
This October hearing page is not just a schedule entry. The supplied DOB extract contains 6 summons records for this property identifier. The charge mix is: 2 Façade / Exterior Wall summonses; 2 Elevator / Vertical Transportation summonses; Sidewalk Shed / Scaffold; Work Without a Permit. The hearing dates are October 13, 2026, October 14, 2026, October 5, 2026, October 7, 2026; the source issue date(s) are August 4, 2026, July 21, 2026, July 29, 2025, March 17, 2025.
Important: The discussion below identifies correction paths, hearing issues and evidence worth investigating from the summons data. It does not state that a defense will succeed. OATH decides liability from the evidence and law presented in the case.
Façade / Exterior Wall — Summons 35718253Z
CLASS - 1 · Issued July 29, 2025; hearing October 5, 2026. · Hearing status: DEFAULT
DOB allegation in the source extract: FAILURE TO MAINTAIN BUILDING FACADE AND APPURTENANCES. OBSERVED DAMAGED MISSING MORTAR JOINTS CRACKED STONE WORK AND SEVERLY CORRODED FIRE ESCAPES ON EXPOSURE 1 IN MULTIPLE LOCATIONS. ALSO SPALLING BRICK WORK/D
Cited provision(s): 104 — 28-302.1 FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES
How this type of condition is typically resolved
Exterior-wall charges usually require a competent inspection of the cited façade/appurtenance, repair of unsafe or deteriorated conditions, and—when the building is subject to FISP—the appropriate QEWI report or amended filing.
Hearing issues to verify
- Does the inspector's description match the actual exposure, floor and defect?
- Was the condition already repaired or protected before the summons date?
- Was there a current FISP/QEWI filing addressing the same condition?
Evidence that may matter
- QEWI report, FISP filing or amended report
- Close-up and elevation photographs identifying the exact defect
- Repair proposals, invoices and completion records
- Engineer/architect letter and inspection documentation
Sidewalk Shed / Scaffold — Summons 39556842N
CLASS - 2 · Issued July 21, 2026; hearing October 7, 2026. · Hearing status: PENDING
DOB allegation in the source extract: AT THE TIME OF MY INSPECTION OF A 6 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1, UPON REVIEW OF THE DEPARTMENT RECORD IT REVEAL THAT THE SIDEWALK SHED PERMIT HAS BEING EXPIRED FROM 05-01-20
Cited provision(s): 2P8
How this type of condition is typically resolved
The issue is typically whether the shed/scaffold was permitted, properly installed and maintained, and whether the equipment matched the approved filing and current safety requirements. Correction can involve permit renewal, physical modification, inspection, or removal.
Hearing issues to verify
- Was the equipment covered by an active permit on the inspection date?
- Did the installed dimensions/protection match the approved design?
- Was a cited defect already corrected before the summons was issued or served?
Evidence that may matter
- DOB NOW equipment permit and approved drawings
- Engineer/contractor inspection logs
- Dated site photographs
- Renewal or removal records
Façade / Exterior Wall — Summons 39141912P
CLASS - 1 · Issued March 17, 2025; hearing October 13, 2026. · Hearing status: DEFAULT
DOB allegation in the source extract: OBS @EXPOS:#1,2&3&4 @ MAIN ENTRANCE WALL BULGING OUT/ SPALLING CONCRETE THROUGHOUT FACADE,& MASONRY MISSING MORTAR DEFACE BRICKS DAMAGED,CRACKED,SPALLED.MORTAR JOINTS DETERIORATED DAMAGED CHIMNEY,CRACKED STONE
Cited provision(s): 102 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER
How this type of condition is typically resolved
Exterior-wall charges usually require a competent inspection of the cited façade/appurtenance, repair of unsafe or deteriorated conditions, and—when the building is subject to FISP—the appropriate QEWI report or amended filing.
Hearing issues to verify
- Does the inspector's description match the actual exposure, floor and defect?
- Was the condition already repaired or protected before the summons date?
- Was there a current FISP/QEWI filing addressing the same condition?
Evidence that may matter
- QEWI report, FISP filing or amended report
- Close-up and elevation photographs identifying the exact defect
- Repair proposals, invoices and completion records
- Engineer/architect letter and inspection documentation
Work Without a Permit — Summons 39141927H
CLASS - 1 · Issued March 17, 2025; hearing October 13, 2026. · Hearing status: DEFAULT
DOB allegation in the source extract: OBS STRUCT WORK @FIRE ESCAPE THROUGHOUT PREMISES, ASPER SUPER OF THE BUILD WHO INFORMED ME ALL WORK IS FULLY COMPLETED ON FIRE ESCAPES REMOVAL LANDING STAIRS RUNGS, PLATFORMS CONNECT IT LADDERS STAIRS GRATINGS
Cited provision(s): 101 — 28-105.1 WORK WITHOUT A PERMIT
How this type of condition is typically resolved
The correction path usually starts by determining whether the observed work required a permit and whether the condition can legally remain. If it can remain, legalization may require plans, a filing, permit, inspections and closeout; if it cannot or the owner does not want to legalize it, restoration to a lawful condition may be required.
Hearing issues to verify
- Did a valid permit already cover the exact work described by the inspector on the issue date?
- Was the cited activity actually permit-required work, or was it maintenance / exempt work under the applicable facts?
- Do the approved drawings, permit scope and inspection history match the condition the inspector described?
- If a Stop Work Order was issued, was the work stopped and was any later work performed only after the required authorization?
Evidence that may matter
- Permit and DOB NOW/BIS job records that predate the inspection
- Approved plans and amendments showing the cited work
- Dated photographs of the condition and construction stage
- Contracts, invoices and contractor statements establishing what work was actually performed
- Inspection / sign-off records if the work was subsequently legalized
Elevator / Vertical Transportation — Summons 39199125H
CLASS - 1 · Issued August 4, 2026; hearing October 14, 2026. · Hearing status: PENDING
DOB allegation in the source extract: 1) THE IN-BOARD MOTOR-BEARING IS WORN AND NEEDS TO BE REPLACED (8.11.2.1.2). 2) THE BRAKE TAG AND THE CAT-1 TAG IS EXPIRED/MISSING (8.11.1.6). 3) THERE ARE PIPES IN THE MOTOR-ROOM THAT MAY BE COVER WITH ASBESTO
Cited provision(s): 151 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: SERVICE EQUIPME
How this type of condition is typically resolved
Elevator charges often require licensed-elevator maintenance or repair, the required periodic inspection/test filing, an affirmation of correction where applicable, and reinspection for hazardous conditions.
Hearing issues to verify
- Does the device number/location on the summons match the building's elevator record?
- Was the cited defect repaired or the device removed from service before the inspection?
- Were the required CAT/periodic inspection filings timely and accepted?
Evidence that may matter
- Elevator device record and inspection/test reports
- Maintenance contractor logs and repair tickets
- Affirmation of Correction / reinspection result
- Photographs or controller/service records
Elevator / Vertical Transportation — Summons 39199124X
CLASS - 1 · Issued August 4, 2026; hearing October 14, 2026. · Hearing status: PENDING
DOB allegation in the source extract: 1) THE CAR DOES NOT HAVE UNDER CAR LIGHTING (8.11.2.1.3). 2) THE PIT IS DIRTY (8.11.2.1.3) 3) THE MOTOR WIRES HAVE DAMAGE INSULATION (RAT DAMAGE) (8.11.2.1.2). 4) THE MOTOR-ROOM FLOOR IS DAMAGED. 5) THE DRIVE S
Cited provision(s): 151 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: SERVICE EQUIPME
How this type of condition is typically resolved
Elevator charges often require licensed-elevator maintenance or repair, the required periodic inspection/test filing, an affirmation of correction where applicable, and reinspection for hazardous conditions.
Hearing issues to verify
- Does the device number/location on the summons match the building's elevator record?
- Was the cited defect repaired or the device removed from service before the inspection?
- Were the required CAT/periodic inspection filings timely and accepted?
Evidence that may matter
- Elevator device record and inspection/test reports
- Maintenance contractor logs and repair tickets
- Affirmation of Correction / reinspection result
- Photographs or controller/service records
Case-specific next step
For this property, the first paid review should reconcile the 6 October summons records against the current OATH/DOB record, identify which alleged conditions remain open, and separate the hearing defense from the DOB correction / certification work. That prevents paying for correction work that does not address the actual charge—or appearing at OATH without the documents needed for the cited condition.