What DOB is alleging at this property
This October hearing page is not just a schedule entry. The supplied DOB extract contains 2 summons records for this property identifier. The charge mix is: 2 Elevator / Vertical Transportation summonses. The hearing date is October 28, 2026; the source issue date(s) are August 18, 2026.
Important: The discussion below identifies correction paths, hearing issues and evidence worth investigating from the summons data. It does not state that a defense will succeed. OATH decides liability from the evidence and law presented in the case.
Elevator / Vertical Transportation — Summons 39200894H
CLASS - 2 · Issued August 18, 2026; hearing October 28, 2026. · Hearing status: PENDING
DOB allegation in the source extract: MISALINGED CAB MIRROR (BC 3001.2). INAUDIBLE ALARM BELL (5.6.1.25.). PREVENT MATERIAL FROM INHIBITING MACHINE ROOM ACCESS(2.7.3.1.1.). UNLOCKED MACHINE ROOM DOOR (2.7.3.4.1(A)). MISSING MACHINE ROOM VENTIALTION
Cited provision(s): 251 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER:SERVICE EQUIPMEN
How this type of condition is typically resolved
Elevator charges often require licensed-elevator maintenance or repair, the required periodic inspection/test filing, an affirmation of correction where applicable, and reinspection for hazardous conditions.
Hearing issues to verify
- Does the device number/location on the summons match the building's elevator record?
- Was the cited defect repaired or the device removed from service before the inspection?
- Were the required CAT/periodic inspection filings timely and accepted?
Evidence that may matter
- Elevator device record and inspection/test reports
- Maintenance contractor logs and repair tickets
- Affirmation of Correction / reinspection result
- Photographs or controller/service records
Elevator / Vertical Transportation — Summons 39200893X
CLASS - 2 · Issued August 18, 2026; hearing October 28, 2026. · Hearing status: PENDING
DOB allegation in the source extract: MISALINGED CAB MIRROR (BC 3001.6). PROVIDE DESIGNATED LOBBY BRAILLE TAGS (ADA)> MISSING MACHINE ROOM VENTILATION (APPENDIX K3).
Cited provision(s): 251 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER:SERVICE EQUIPMEN
How this type of condition is typically resolved
Elevator charges often require licensed-elevator maintenance or repair, the required periodic inspection/test filing, an affirmation of correction where applicable, and reinspection for hazardous conditions.
Hearing issues to verify
- Does the device number/location on the summons match the building's elevator record?
- Was the cited defect repaired or the device removed from service before the inspection?
- Were the required CAT/periodic inspection filings timely and accepted?
Evidence that may matter
- Elevator device record and inspection/test reports
- Maintenance contractor logs and repair tickets
- Affirmation of Correction / reinspection result
- Photographs or controller/service records
Case-specific next step
For this property, the first paid review should reconcile the 2 October summons records against the current OATH/DOB record, identify which alleged conditions remain open, and separate the hearing defense from the DOB correction / certification work. That prevents paying for correction work that does not address the actual charge—or appearing at OATH without the documents needed for the cited condition.