What DOB is alleging at this property
This October hearing page is not just a schedule entry. The supplied DOB extract contains 2 summons records for this property identifier. The charge mix is: Egress / Exit Obstruction; Site Safety / Safeguarding. The hearing date is October 22, 2026; the source issue date(s) are July 10, 2025.
Important: The discussion below identifies correction paths, hearing issues and evidence worth investigating from the summons data. It does not state that a defense will succeed. OATH decides liability from the evidence and law presented in the case.
Egress / Exit Obstruction — Summons 39542236X
CLASS - 2 · Issued July 10, 2025; hearing October 22, 2026. · Hearing status: DEFAULT
DOB allegation in the source extract: CS ALLOWED WORKERS TO WORK ON SOE /CONFINED SPACE W/OUT PROPER MEANS OF EGRESS/ INGRESS, MISSING GUARDRAILS, CAZ, SIGNS, LIGHTS, NO SAFE PROTOCOLS RECORDED/ DOCUMENTED. WORK AREA IS DETRIMENTAL ZONE FOR WORKERS
Cited provision(s): 2G5 — BC 3301.13.7 THROUGH BC 3301.13.13 CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES PER CODE.
How this type of condition is typically resolved
Egress charges are generally corrected by removing the obstruction or restoring the required exit width/path and then documenting that the means of egress is clear and code compliant.
Hearing issues to verify
- Was the cited passageway actually required egress for the affected occupancy?
- Did the alleged obstruction exist when the inspector observed it?
- Was the condition immediately removed and can the timing be documented?
Evidence that may matter
- Dated photographs showing the exit path
- Approved floor/egress plans
- Building or security logs
- Statements or work records documenting removal of stored items/obstructions
Site Safety / Safeguarding — Summons 39542253H
CLASS - 2 · Issued July 10, 2025; hearing October 22, 2026. · Hearing status: DEFAULT
DOB allegation in the source extract: OBSERVED A DEEP SOE W/ WOOD SHORING COVERED BY PLYWOOD CREATING CONFINED SPACE , ONLY 1 EXTENSION LADDER FOR EGRESS/ INGRESS. WORK BEING PERFOMED UNDER HIGH TEMPERATURES. WORK AREA & STRUCTURE IS A DETRIMENTAL
Cited provision(s): 209 — BC 3301.2,27-1009(A) FAIL TO SAFEGUARD PERS/PROPERTY AFFECTED BY CONSTRUCTION OP
How this type of condition is typically resolved
These charges focus on protection of workers, occupants, neighboring property or the public during construction. Correction normally requires fixing the specific unsafe condition, documenting required safety measures and keeping the required site records current.
Hearing issues to verify
- What precise safety measure does the summons say was missing or inadequate?
- Was the condition temporary and corrected before or during the inspection?
- Did an approved site-safety plan or required site document address the cited condition?
Evidence that may matter
- Site Safety Plan / logistics drawings
- Daily safety logs and competent-person/site-safety records
- Photographs taken around the inspection time
- Contractor or safety-manager statements and correction records
Case-specific next step
For this property, the first paid review should reconcile the 2 October summons records against the current OATH/DOB record, identify which alleged conditions remain open, and separate the hearing defense from the DOB correction / certification work. That prevents paying for correction work that does not address the actual charge—or appearing at OATH without the documents needed for the cited condition.
Submit These Summonses for Review