Examples under OATH infraction code 102
535 distinct enforcement-description examples carrying this infraction code. Check the actual summons before interpreting the code.
- Masonry or façade deterioration · 39203468ZSection 28-301.1 / OATH code 102 · OBSERVED AT EXP 1 FRONT OF THE BUILDING THE ROOF SINGLES AT SECOND LEVEL REMAINS IN A STATE OF DISREPAIR AND AT EXP 2 OBSERVED LAR
- Masonry or façade deterioration · 39203887NSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION FACADE HAD SIGNIFICANT CRACKING THROUGHOUT AND ALON
- Fire prevention or detection system · 39194893HSection 28-301.1 / OATH code 102 · OBSERVED IN BASMENT LAUNDRY LACK OF SPRINKLER COVERAGE AND OPEN ENDED GAS LINE. PER FGC 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC
- Masonry or façade deterioration · 39203677PSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION, OBSERVED EXTERIOR WALL DISREPAIR AND FACADE DETERIORATION AT EXPOSURES 1 AND 4, INCLUDING MULTIPLE VERTICAL
- Zoning, site use or regulated sign · 39196969YSection 28-301.1 / OATH code 102 · AT THE TIME OF INSPECTION, THE CORNICE STONE AT EXPOSURE 1 (FRONT ELEVATION) WAS OBSERVED TO BE IN A STATE OF SIGNIFICANT DISREPAI
- Boiler device inspection and filing · 39203624LSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. OBSERVED NO FIRE STOP AT ANY OF THE NECESSARY LOCATION, LAUNDRY ROOM OR C
- Structural and interior building component · 39204030ZSection 28-301.1 / OATH code 102 · AT THE TIME OF INSPECTION, OBSERVED FAILURE TO MAINTAIN HOUSEKEEPING STANDARDS ON THE FIRST AND SECOND FLOORS DUE TO EXCESSIVE CON
- Safe building maintenance · 39203943ZSection 28-301.1 / OATH code 102 · ATOI, OBSERVED EXCESSIVE COMBUSTIBLE WOOD CONSTRUCTION DEBRIS PILED UP AT EXPOSURE 1 RAISING CONCERNS FOR POTENTIAL FIRE, REPAIR A
- Authorized use versus observed occupancy · 39203908NSection 28-301.1 / OATH code 102 · NOTED AT THE TIME OF INSPECTION, THE SOFFIT PANELS AT THE BALCONIES SERVING APARTMENTS 3R, LOCATED AT EXPOSURE #3 (REAR FACADE) OF
- Masonry or façade deterioration · 39177039YSection 28-301.1 / OATH code 102 · SHED AT EXPOSURE 1(2 AVE) AND 2 (EAST 119 STREET) NOT MAINTAIN AS PER CODE SECTION OF PARAPET PANELS HAVE FALLEN OFF OR MISSING. C
- Means of egress and exit protection · 39204039PSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION OBSERVED ROOF ACCESS FROM RIGHT SIDE DOOR ACCESS OBSTRUCTED BY FURNITURE, STAIRCASE B AT 5 FLOOR OBSTRUCTED
- Windows, doors and openings · 39203566MSection 28-301.1 / OATH code 102 · AGGRAVATED CONDITIONS OBSERVED, CONSISTENT WITH VIOLATION #39089687M ISSUED 7/5/2023 FOR FAILURE TO MAINTAIN. EXPOSURES 1, 2 & 4 S
- Authorized use versus observed occupancy · 35720580ZSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. FAILURE TO PROVIDE REQUIRED NATURAL LIGHT AND VENTILATION FOR EVERY BEDRO
- Authorized use versus observed occupancy · 39177534LSection 28-301.1 / OATH code 102 · VIOLATION ISSUED FOR FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER .ATOI OBSERVED ON THE 1ST FL AND BASEMENT IMPROPER STOR
- Structural and interior building component · 39202867LSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF REINSPECTION FOR VIO#39145038X. GATE AT EXP#1 IS STILL DETACHED
- Structural and interior building component · 39166654MSection 28-301.1 / OATH code 102 · OBSERVED FRONT PORCH REBUILT AND NO RAILINGS OR TEMP RAILINGS IN PLACE AT PORCH OR STAIRS. PORCH APPROX 42" ABOVE GRADE. POTENTIAL
- Authorized use versus observed occupancy · 39204230NSection 28-301.1 / OATH code 102 · MISSING FIRESTOPPING IN CELLAR BELOW OCCPD 1ST FL APTS. OBSVD IN THE CORNER OF EXP 3&4 ROOM APPROX 2500 SF W/ALL EXPOSED WOOD JOIS
- Plumbing fixture and drainage configuration · 39204222NSection 28-301.1 / OATH code 102 · AT THE TIME OF INSPECTION LOCATED IN THE BASEMENT GYM OBSERVED AN ACTIVE WATER LEAK COMING FROM A WASTE OR WATER LINE. CONTRARY TO
- Authorized use versus observed occupancy · 39204220JSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION OBSERVED STAIRS AT SUBCELLAR LEADING INTO MECHANICAL ROOM IN STATE OF DISREPAIR, THE STEEL STAIR TREAD WAS R
- Construction fencing or site enclosure · 39204143PSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION - 1. RAZOR BARBED WIRE OBSERVED ATTACHED TO TO
- Masonry or façade deterioration · 39166656XSection 28-301.1 / OATH code 102 · OBSERVED AT EXP 3 REAR YARD PILES OF DEBRIS. LARGE PILE OF OLD BRICK APPROX 4 YDS. ALSO PILES OF CONSTRUCTION DEBRIS. OLD METAL, W
- Fire prevention or detection system · 39204215PSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. OBSERVED AT UPPER FLOORS 3RD, 4TH, 5TH PUBLIC HALLWAY OBSTRUCTED BY HOUSEHO
- Safe building maintenance · 39204090KSection 28-301.1 / OATH code 102 · ATOI OBSERVED SECTION OF Q-DECKING BEING RUSTED OUT UNDERNEATH THE VAULT SECTION OF THE SIDEWALK NEXT TO THE BUILDING GRATE., REPA
- Means of egress and exit protection · 39204228YSection 28-301.1 / OATH code 102 · AT EXP 3 OBSERVED FIRESCAPE DROP DOWN LADDERS BLOCKED BY DEBRIS. ADDITIONALLY THE EGRESS PATH AT EXP 2 AND THROUGH THE BLDG IS BLO
- Windows, doors and openings · 39196689JSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT APARTMENT #3B THE SILL BRICK WAS LOOSE AND WHEN THE WINDOW OPENED THE BR
- Masonry or façade deterioration · 39204062NSection 28-301.1 / OATH code 102 · NOTED AT THE TIME OF INSPECTION, MASONRY FACADE CRACKING WAS OBSERVED AT EXPOSURE #1 (FRONT FACADE) AT THE GROUND LEVEL ABOVE THE
- Authorized use versus observed occupancy · 39177668RSection 28-301.1 / OATH code 102 · ATOI, OBSERVED SUBJECT PROPERTY CELLAR FILLED WITH APPROXIMATELY 3 FEET OF FROZEN STANDING WATER. FROZEN STANDING WATER HAS THE PO
- Masonry or façade deterioration · 39204109LSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT ROOF ANTENNA FELL ONTO ROOF, AT EXPO 1(FR
- Masonry or façade deterioration · 35718973RSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. I OBSERVED HAZARDOUS CONDITION ALONG THE EXTERIOR WALL OF THE BUILDING. AT
- Authorized use versus observed occupancy · 39204158HSection 28-301.1 / OATH code 102 · LACK OF AIR LIGHT,AND VENTILATION FOR ILLEGAL SRO. AT CELLAR, REPAIR AND/REPLACE
- Roof and weather protection · 39178077JSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING CODE COMPLIANT. NOTED: THE FRONT PORCH ROOF IS IN DISREPAIR WITH METAL TRIM HANGING. THE CENTER SECTI
- Gas equipment or fuel piping · 39204227MSection 28-301.1 / OATH code 102 · MULTPL IMPROPER/MALFUNCTIONING FIRE DOORS. EGRESS AT EXP 2 DOOR TO SIDEWALK DOES NOT SELF CLOSE AND MISSING PANIC HRDWRE. GAS METE
- Boiler device inspection and filing · 39204178PSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE COMPLAINT MANNER. OBSERVED ENCLOSED BOILER ROOM AT CELLAR IS NOT PROPERLY FIRE RATED AND DO
- Masonry or façade deterioration · 39195460RSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN ENTRANCE STOOP. AT THE TIME OF INSPECTION, THE MASONRY ENTRANCE STOOP AT EXPOSURE 1 1ST STORY EXHIBITED STRESS
- Masonry or façade deterioration · 39142641RSection 28-301.1 / OATH code 102 · PARAPET WALL EXPOSE 1 IS IN AN UNSAFE CONDITION AND NEEDS IMMEDIATE ATTENTION. PARAPET WALL STRUCTURALLY COMPROMISED LEANING FORWA
- Fire prevention or detection system · 35725815RSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE IS REQUIRED AS PER BC 903.
- Boiler device inspection and filing · 39195694JSection 28-301.1 / OATH code 102 · SSUED NOV FAILURE TO MAINTAIN OBSERVED DOOR TO BOILERROOM OPEN WITH NO VENTILATION OR USABLE DAMPER IN CASE OF FIRE, DOOR 24X48 LH
- Gas equipment or fuel piping · 39204223PSection 28-301.1 / OATH code 102 · ATOI OBSERVED A OPEN LIVE GAS LINE BEING TRACED BACK TO METER FOR APT 4B, ALSO THERE WAS A TEE SENDING TO 2 OTHER LOCATIONS UNABLE
- Roof and weather protection · 39204058KSection 28-301.1 / OATH code 102 · RCA ISSUED 02/22/25 SAME RESPONDENT FAILURE TO MAINTAIN 28-301.1 AT EXP 2&4 RAINSTORM GUTTERS THAT WERE HANGING HAVE BEEN REMOVED
- Safe building maintenance · 39178401MSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION FOR VIO#39139175L,CONDITIONS STILL EXIST REAR OF BLD
- Masonry or façade deterioration · 39195749HSection 28-301.1 / OATH code 102 · AT THE TIME OF INSPECTION, OBSERVED A SECTION OF MASONRY AT THE 5TH STORY, EXPOSURE 1, DEFLECTING OUTWARD AND IN DISREPAIR. ADDITI
- Plumbing fixture and drainage configuration · 39195860XSection 28-301.1 / OATH code 102 · ATOI OBSERVED UNAUTHORIZED NEWLY INSTALLED NON FIRE RATED PVC USED FOR HOT WATER HEATER VENT PIPING., REPAIR AND/REPLACE
- Authorized use versus observed occupancy · 39195522NSection 28-301.1 / OATH code 102 · ATOI, FAILURE TO MAINTAIN OBSERVED FOR EXCESSIVE DUST WAS ON THE SIXTH AND FIFTH FLOORS IN A OCCUPIED HALLWAY DUE TO ONGOING SCRAP
- Masonry or façade deterioration · 39204375YSection 28-301.1 / OATH code 102 · ATOI OBSERVED SPALLING/CRACKED STUCCO AND DETERIORATED BRICKS/MORTAR JOINTS AT EXPOSURE #3 FACADE., REPAIR AND/REPLACE
- Windows, doors and openings · 39204357KSection 28-301.1 / OATH code 102 · NOTED AT THE TIME OF INSPECTION, OBSERVED A VERTICAL CRACK AT EXPOSURE #1, FRONT FACADE OF THE PROPERTY, EXTENDING FROM THE SECOND
- Boiler device inspection and filing · 39204374MSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ATOI OBSERVED HAIRLINE CRACKS AT EXPOSURE 4 BELOW / ABOVE WINDOWS AND CHIMN
- Authorized use versus observed occupancy · 39195653NSection 28-301.1 / OATH code 102 · RCA ISSUED 03/03/25 TO SAME RESPONDENT CONDITIONS HAVE WORSENED, FAILURE TO MANTAIN BLDG & LOT SAFE 28-301.1, AT ALL EXP'S EXCESSI
- Safe building maintenance · 39204275RSection 28-301.1 / OATH code 102 · NOTED: ECB VIOLATION ISSUED FOR FTM DUE TO EXCESSIVE DEBRIS. ATOI OBSERVED AN EXCESSIVE AMOUNT OF CONSTRUCTION DEBRIS PILED UP AT
- Fire prevention or detection system · 35729218RSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED AS PER BC 903.2 A
- Masonry or façade deterioration · 35718972PSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. I OBSERVED HAZARDOUS CONDITIONS ALONG EXPOSURE ONE-FACING EAST MOSHOLU PKWY
- Masonry or façade deterioration · 39192964RSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. ATOI, I OBSERVED AT THE FRONT THE BUILDING AT EXPOSURE#1, AT THE SECOND LEV
- Structural and interior building component · 39195867ZSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN. ATOI AT A 2.75 WALK OBSERVED STRUCTURAL WOOD ROT IN THE SECOND-FLOOR LOAD-BEARING STRUCTURAL GIRDER DIRECTLY
- Masonry or façade deterioration · 39153294PSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER; OBSERVED BALCONY AT EXP 1 IN STATE OF DISREPAIR. LOOSE BRICKS SEPARATING FR
- Authorized use versus observed occupancy · 39204133LSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDINGS IN CODE COMPLIANT MANNER: ATOI ACCESS TO CELLAR SEWERS BACK UP CREATES HAZARD CONDITIONS FOR TENANTS
- Plumbing fixture and drainage configuration · 39196289KSection 28-301.1 / OATH code 102 · IN BASEMENT APARTMENT D, IN BATHROOM,CEILING HAS COLLAPSED. IN APARTMENT ABOVE 1E BATHROOM FLOOR SAGS., REPAIR AND/REPLACE; VACATE
- Structural and interior building component · 39163416NSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. A TIME OF INSPECTION OBSERVED EXISTING WOOD STAIRCASE IN A STATE OF DISREPA
- Gas equipment or fuel piping · 39204455YSection 28-301.1 / OATH code 102 · OBSERVED AT APT #D1 AT 4TH FLOOR GAS WORK DUE STOVE WAS REMOVED WHOLES LINE TO STOVE WAS CUT OFF AND NOT CAPED VALVE APPEARS TO BE
- Gas equipment or fuel piping · 39204423JSection 28-301.1 / OATH code 102 · ATOI OBSERVED ON THE ROOF GAS PIPING NEEDING TO BE MAINTAINED SOME PARTS NOT PAINTED ALSO SOME PARTS RUSTED. GAS PIPE MUST BE PROP
- Zoning, site use or regulated sign · 39161763ZSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION AT FRONT YARD LARGE ACCUMULATION OF MISCELLANEOUS HOU
- Fire prevention or detection system · 39204427RSection 28-301.1 / OATH code 102 · ATOI OBSERVED IN THE GARAGE AREA A MAKE SHIFT CAR DETAILING SHOP IN WHICH THEY HAD A HOSE PULLING WATER FROM A HOSE BIB CONNECTED
- Authorized use versus observed occupancy · 39204597JSection 28-301.1 / OATH code 102 · AT REAR OF BUILDING,AT 3RD FLOOR, SIDING FINISH MISSING EXPOSING ROOM TO THE ELEMENTS. INTERIOR OF APARTMENT,CERAMIC TILES MISSING
- Plumbing fixture and drainage configuration · 39204425NSection 28-301.1 / OATH code 102 · ATOI OBSERVED THE WATER HEATERS ON THE 3RD AND 4TH FLOOR BEING HOUSED IN A TIGHT CLOSET NOT ALLOWING ACCESS TO THE WATER HEATERS F
- Safe building maintenance · 39203512RSection 28-301.1 / OATH code 102 · AGGRAVATED CONDITIONS OBSERVED AT TIME OF INSPECTION, CONSISTENT WITH VIOLATION #39153716X ISSUED 7/11/2025 FOR FAILURE TO MAINTAI
- Masonry or façade deterioration · 35683916NSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. OBSERVED LOOSE BRICK WORK, LARGE STEP CRACKS, CRACKED STONEWORK, SPALLING
- Roof and weather protection · 39202679YSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER. OBSERVED ROOF IN A STATE OF DISREPAIR, OPEN HOLES OBSERVED AT EXP 1 & 2. SH
- Unprotected openings and fall exposure · 39204461KSection 28-301.1 / OATH code 102 · IN REAR YARD, NO FALL PROTECTION OR GUARDRAILS ON OPENING WHERE LADDER IS OBSERVED. WIRES, LADDERS, AND OTHER EQUIPMENT BEING UNMA
- Zoning, site use or regulated sign · 39163383XSection 28-301.1 / OATH code 102 · ATOI OBSERVED A DOZEN RETAIL TYPE PLYWOOD TABLES ALONG EXP 2 AT SIDE OF SIDEWALK. POTENTIAL FOR INJURY TO PEDESTRIANS. ALSO IN REA
- Authorized use versus observed occupancy · 39204577MSection 28-301.1 / OATH code 102 · ECB VIOLATING ISSUED FOR FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER: ATOI OBSERVED IN THE INTERIOR OF THE RESIDENT NO G
- Safe building maintenance · 39204462MSection 28-301.1 / OATH code 102 · 1RCNY TABLE 1 (STREET). STRUCTURE BEING ILLEGAL BUILT UP TO LOT LINE, CREATING HAZARDOUS CONDITIONS JUST IN CASE OF EMERGENCY RESP
- Masonry or façade deterioration · 39197055MSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN. AT TIME OF INSPECTION, SPAULING AND BROKEN CONCRETE, SHIFTED, CRACKED STONE STEPS, CAUSING TRIPPING HAZARDS F
- Masonry or façade deterioration · 39204445KSection 28-301.1 / OATH code 102 · OBSERVED STAIRCASE WALL/HALLWAY WITH MULTIPLE HOLES AND CRACKS AT 4TH FLOOR OUTSIDE APT D1, REPAIR AND/REPLACE
- Windows, doors and openings · 39203952KSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION OBSERVED AT EXP. #1 CRACKED/CHIPPED WINDOWSILLS AND HOLES IN MASONRY BETWEEN 4TH FLOOR AND PARAPET LEVEL AND
- Authorized use versus observed occupancy · 39196332RSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT INTERIOR APARTMENT 3R & BASEMENT ROOM AT
- Plumbing fixture and drainage configuration · 39204424LSection 28-301.1 / OATH code 102 · ATOI OBSERVED HOT WATER HEATERS ON THE 3RD & 4TH FLOORS INSTALLED USING PVC ON THE FRESH AIR INTAKES AND ON THE THIRD FLOOR THE FR
- Roof and weather protection · 39204379LSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED ROOF-LEVEL METAL CORNICE DETERIORATED WIT
- Roof and weather protection · 39204108JSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER, EXCESSIVE DEBRIS AT (EXP 1,3,4), CANOPY ROOF AT REAR (EXP 3) IN STATE OF DI
- Gas equipment or fuel piping · 39204336LSection 28-301.1 / OATH code 102 · ATOI OBSERVED IN THE GAS METER ROOM MULTIPLE LEAKS ON THE HOUSE SIDE OF THE SERVICE. CON EDISON ARRIVE & SHUT DOWN & LOCKED SERVIC
- Plumbing fixture and drainage configuration · 39166024HSection 28-301.1 / OATH code 102 · NEW PVC AND COOPER PIPE INSTALLED IN BATHROOMS OF ALL 3 FLOORS. APPROX 85% COMPLETE. WWP., REPAIR AND/REPLACE
- Boiler device inspection and filing · 39204436ZSection 28-301.1 / OATH code 102 · ATOI OBSERVED IN BASEMENT OPEN ENDED GAS LINE. ORIGINALLY FEEDING BOILER AND HOT WATER HEATER. PER B102 CLASS 1 28-301.1 FAILURE T
- Electrical installation and permit · 39203697MSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HOLES AT CEILING EXPOSING WOODEN JOISTS, AND BROKEN ELECTRICAL LIG