- Specific cited provision requiring manual cross-check · 39558490HSection UNSPECIFIED / OATH code 1P7 · OBSERVED: SITE CLOSED UPON EXTERIOR INSPECTION NOTED FENCE LINING OUTWARD, HAS ROTTEN PANELS ,NOT IN PROPERTY LINE ,NOT UNIFORM PA
- Sidewalk shed and public protection · 39556505MSection UNSPECIFIED / OATH code 1P7 · BC 3307.6.4.4 ATOI , OBSERVED SIDEWALK SHED AT EXP#1 NOT MAINTAINED AS PER CODE. VERTICAL MEMBERS ARE LESS THAN 18 IN. FROM THE CU
- Street / sidewalk occupancy and dot authorization · 39558544YSection UNSPECIFIED / OATH code 1P7 · OBSERVED PROP 12 STORY NB. CLOSED SITE. AT TIME OF INSPECTION OBSERVED EXCAVATOR MACHINE ACROSS STREET FROM SITE WITH NO PROTECTIO
- Scaffold platform and fall protection · 39558521LSection UNSPECIFIED / OATH code 1P7 · 3314.6 OBS. SUSP. SCAFFOLD RIGGED AND READILY AVAIL. FOR USE. ROPES/LIFELINES KNOTTED TO EXPOSED REBAR AS TIEBACKS/ANCHORS; REBAR
- Zoning, site use or regulated sign · 39558507PSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF INSPECTION OF THE 12-STORY PROPOSED NB, ACTIVE FOUNDATION WORK WAS OBSERVED REBAR. REVIEW OF THE SSM AND SSC LOGBOO
- Scaffold platform and fall protection · 39202486HSection UNSPECIFIED / OATH code 1P7 · FAILURE TO PROPERLY ERECT AND MAINTAIN SUPPORTED SCAFFOLDING. AT TIME OF INSPECTION, SUPPORTED SCAFFOLDING AT EXPOSURE 1 WAS OBSER
- Fire prevention or detection system · 39558573NSection UNSPECIFIED / OATH code 1P7 · BC3303.7.2 * BC 3301.1.2 NOTED : ACTIVE SITE CP PRESENT UPON INSPECTION NOTED NO ONE FIRE EXTINGUISHER ON SITE CONTRARY TO NYC FIR
- Demolition, structural removal or excavation · 39558588XSection UNSPECIFIED / OATH code 1P7 · I OBSERVED EXCAVATION TAKING PLACE AT EXPOS 3 YARD BEYOND 5FT WITH AN INADEQUATE SUPPORT OF EXCAVATION INSTALLED. UPON REQUEST TO
- Unprotected openings and fall exposure · 39558631MSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF INSPECTION OBSERVED, ACTIVE JOBSITE MISSING GUARDRAILS SYSTEMS THROUGHOUT STAIRWAYS ON ALL FLOORS CONTRARY TO BC 33
- Means of egress and exit protection · 39558626HSection UNSPECIFIED / OATH code 1P7 · AT TIME OF INSPECTION, OBSERVED REQUIRED MEANS OF EGRESS STAIRWAYS AT MULTIPLE FLOORS NOT ADEQUATELY MAINTAINED AND IN PLACE DURIN
- Scaffold platform and fall protection · 39558625XSection UNSPECIFIED / OATH code 1P7 · AT TIME OF INSPECTION, OBSERVED SUPPORTED SCAFFOLD ABOVE SIDEWALK SHED AT EXPOSURE 1 WITH INADEQUATE GUARDRAIL SYSTEM, PLATFORM PL
- Zoning, site use or regulated sign · 39558627JSection UNSPECIFIED / OATH code 1P7 · AT TIME OF INSPECTION, OBSERVED MATERIAL HOIST INSTALLED AND IN USE AT STAIRWAY. UPON REQUEST FOR DESIGN DRAWING, NONE WERE MADE A
- Fire prevention or detection system · 39558600JSection UNSPECIFIED / OATH code 1P7 · I OBSERVED A GARAGE BEING USED AS STORAGE SHED. STORAGE AREA WAS PACKED WITH EQUIPMENT, MATERIAL AND COMBUSTIBLE MATERIAL. I OBSER
- Scaffold platform and fall protection · 39555840PSection UNSPECIFIED / OATH code 1P7 · BC 3314.1 ATOI, OBSERVED SUPPORTED SCAFFOLD INSTALLED AT EXP# 1 ON TOP OF THE SIDEWALK SHED, BUT NOT MAINTAINED AS PER CODE REQUIR
- Scaffold platform and fall protection · 39558792NSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF MY INSPECTION OBSERVED ACTIVE WITH IMPROPERLY INSTALLED SUPPORTED SCAFFOLD @ EXP. 3 MISSING MULTIPLE SAFETY COMPONE
- Unprotected openings and fall exposure · 39558791LSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE WITH WORKER NEAR INADEQUATE SHEAR CUT/SLOPE @ REARYARD WITHOUT A PROPER GUARDRAI
- Scaffold platform and fall protection · 39558648ZSection UNSPECIFIED / OATH code 1P7 · UPON INSPECTION I OBSERVED PIPE SCAFFOLD INSTALLED AND IN USE AT EXPOS 1 IN A UNSAFE MANNER CONTRARY TO CODE 3314.1 . INADEQUATE A
- Scaffold platform and fall protection · 39558683YSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE WITH UNPROTECTED POWERLINES NEAR ERECTED SUPPORTED [email protected]&2(3314.4.4.12)
- Scaffold platform and fall protection · 39558770MSection UNSPECIFIED / OATH code 1P7 · AT TIME OF INSPECTION, SITE WAS OBSERVED UTILIZING A PLATFORM/ PUMP JACK SCAFFOLD SYSTEM AT EXP 2. REQUIRED DRAWINGS FOR PLATFORM
- Plumbing fixture and drainage configuration · 39558731JSection UNSPECIFIED / OATH code 1P7 · BC 3303.2.4-AT THE TIME OF INSPECTION OF AN ACTIVE CONSTRUCTION SITE, A FAILURE TO PROVIDE REQUIRED TOILET FACILITIES WAS OBSERVED
- Scaffold platform and fall protection · 39558806PSection UNSPECIFIED / OATH code 1P7 · 3314.3.4 OBS. SUPPORTED SCAFFOLD ERECTED ON NEEDLE BEAMS & SIDEWALK SHED. REQ'D LOADS IMPOSED LETTER SIGNED/SEALED/DATED BY RDP WA
- Scaffold platform and fall protection · 39558814PSection UNSPECIFIED / OATH code 1P7 · FAILURE TO COMPLY WITH BC3314.8 - 3314.9.4. OBSERVED SUPPORTED SCAFFOLD WITH LOSE AND UNSECURED DEBRIS NETTING ON SEVERAL LEVELS W
- Fire prevention or detection system · 39202930PSection UNSPECIFIED / OATH code 1P7 · AT TIME OF INSPECTION OBSERVED AT 3RD FLOOR PROPANE TORCH WHERE NO FIRE EXTINGUISHER OBSERVED AT THIS FLOOR, FALL PROTECTION ( GUA