Examples under OATH infraction code 204
25 distinct enforcement-description examples carrying this infraction code. Check the actual summons before interpreting the code.
- Roof and weather protection · 39203081YSection 28-302.1 / OATH code 204 · AT THE TIME OF INSPECTION, DETERIORATING CONDITIONS WERE OBSERVED AT THE REAR GARAGE WALLS, WHICH APPEAR TO BE THE RESULT OF INADE
- Zoning, site use or regulated sign · 39202953HSection 28-302.1 / OATH code 204 · FAILURE TO MAINTAIN BUILDING AND ALL PARTS THEREOF IN A CODE-COMPLIANT MANNER. NOTED AT EXPOSURE 4 & 3 AN ILLEGAL CURB CUT, APPROX
- Windows, doors and openings · 35730100JSection 28-302.1 / OATH code 204 · FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: AT THE TIME OF INSPECTION OBSERVED: (1)CRACKED WINDOW GLASS
- Windows, doors and openings · 35729674KSection 28-302.1 / OATH code 204 · FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: AT THE TIME OF INSPECTION OBSERVED: CRACKED WINDOW GLASS AT
- Windows, doors and openings · 39204321ZSection 28-302.1 / OATH code 204 · ECB VIOLATION ISSUED FOR FAILURE TO MAINTAIN. ATOI, OBSERVED EXTERIOR WINDOW LINTELS AT EXPO. #1 FACADE ON 1ST AND 3RD FLOOR SAGGI
- Plumbing fixture and drainage configuration · 39196238KSection 28-302.1 / OATH code 204 · F.T.M.B IN A CODE-COMPLIANT MANNER: A 2-STORY BUILDING WITH IMPROPER STORM WATER DRAINAGE. ROOF LEADERS AND DOWNSPOUTS AT THE FRON
- Masonry or façade deterioration · 39176910LSection 28-302.1 / OATH code 204 · MINOR CRACK @ EXPOSURE 1 AT APPROXIMATELY 6 INCHES. OBSERVED LEANING, MAINTAIN EXTERIOR BUILDING WALL; MAINTAIN EXTERIOR BUILDING
- Zoning, site use or regulated sign · 39196729PSection 28-302.1 / OATH code 204 · ATOI, OBSERVED AT EXPOSURE #1 THAT THE FRONT-YARD CURB HAD BEEN LOWERED TO APPROX. 1 INCH D X 11FT W FROM THE GRADE LEVEL CREATING
- Masonry or façade deterioration · 35730101LSection 28-302.1 / OATH code 204 · FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: AT THE TIME OF INSPECTION OBSERVED: (1)AT EXPOSURE #2(EAST E
- Authorized use versus observed occupancy · 39159205LSection 28-302.1 / OATH code 204 · FAILURE TO MAINTAIN BUILDING WALLS. AT TIME OF INSPECTION OBSERVED STEP CRACKS AND STAINS ON MASONRY FACADE EXPOSURE#4 ALONG THE H
- Masonry or façade deterioration · 35717977JSection 28-302.1 / OATH code 204 · FAILURE TO MAINTAIN BUILDING FACADE WALL"S" AND APPURTENANCES, NOTE: AT THE TIME OF INSPECTION I OBSERVED AT EX #4, EAST ELEVATION
- Zoning, site use or regulated sign · 39197283YSection 28-302.1 / OATH code 204 · ATOI, OBSERVED A LEGAL 2-STORY BUILDING WITH A CHAIN-LINK FENCE EXCEEDING THE MAXIMUM PERMITTED HEIGHT IN AN R5 RESIDENTIAL ZONING
- Means of egress and exit protection · 39197132RSection 28-302.1 / OATH code 204 · FAILURE TO MAINTAIN BUILDING IN A COMPLIANT MANNER. A.T.O.I OBSERVED 7 STORY MULTI-DWELLING BUILDING THE DROP LADDER EXPOSE. 1 & 2
- Masonry or façade deterioration · 35686266YSection 28-302.1 / OATH code 204 · FAILURE TO MAINTAIN EXTERIOR BUILDING FACADES AND APPURTENANCES. NOTED: AT EXP 1(S. ELEV) THERE ARE CRACKED STUCCO AT PARAPET LEVE
- Zoning, site use or regulated sign · 39162865YSection 28-302.1 / OATH code 204 · FAILURE TO MAINTAIN BLDG. & ALL PARTS THEREOF IN A CODE-COMPLIANT MANNER. EXP #1 CURB CUT APPROX. 17' WIDE ILLEGAL CURB CUT TO ACC
- Windows, doors and openings · 39171868YSection 28-302.1 / OATH code 204 · AT FRONT OF BUILDING HORIZONTAL CRACK APPEARS AT FOUNDATION LEVEL,ALSO AT EXPOSURE 2, STRESS CRACK APPEARS BETWEEN WINDOWS., MAINT
- Wall / exterior structural condition · 39149696XSection 28-302.1 / OATH code 204 · FAILURE TO MAINTAIN BUILDING(S) OR APPURTENANCES; NOTED: OBSERVED HOLE OPENING THROUGH RIGHT SIDE EXTERIOR WALL., MAINTAIN EXTERIO
- Masonry or façade deterioration · 39201677XSection 28-302.1 / OATH code 204 · FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: AT TIME OF INSPECTION OBSERVED FRONT YARD CMU RETAINING WALL WITH VE
- Masonry or façade deterioration · 39201873NSection 28-302.1 / OATH code 204 · AT FRONT OF BUILDING STRESS CRACKS APPEAR AT ENTRY DOOR,ALSO NOTED SPALLING OF FINISH AND PAINT PEELING ON ALL LEVELS., MAINTAIN E
- Masonry or façade deterioration · 35694099XSection 28-302.1 / OATH code 204 · FAILURE TO MAINTAIN EXTERIOR FACADE AND APPURTENANCES. AT TIME OF INSPECTION OBSERVED STEP CRACK AT EXPOSURE #1(SOUTH) ROOF LEVEL.
- Windows, doors and openings · 39202259HSection 28-302.1 / OATH code 204 · IN APT. 712, IN MASTER BEDROOM, WATER SEEPAGE HAS CAUSED STAINS AND RUST TO APPEAR AT RADIATOR UNDER BEDROOM WINDOW., MAINTAIN EXT
- Masonry or façade deterioration · 39202496LSection 28-302.1 / OATH code 204 · AT LEFT SIDE OF BUILDING, AT 4TH AND 5TH FLOORS,CONCRETE BALCONIES HAS SECTIONS SPALLING AND MISSING CONCRETE., MAINTAIN EXTERIOR
- Wall / exterior structural condition · 39203089ZSection 28-302.1 / OATH code 204 · FAILURE TO MAINTAIN BUILDING WALL FOR MULTIPLE A.C SUPPORT BRACKETS MISSING AT THE FRONT AND SIDE BUILDING OF BOTH FLOORS SECOND A
- Masonry or façade deterioration · 39202974RSection 28-302.1 / OATH code 204 · OBSERVED FACADE SPALLING, PEELING PAINT, AND CRACKED/DETERIORATED STUCCO AT THE PARAPET LEVEL. DETERIORATED MORTAR JOINTS WERE OBS
- Masonry or façade deterioration · 39192316ZSection 28-302.1 / OATH code 204 · FAILURE TO MAINTAIN BUILDING WALLS/APPURTENANCES. AT TIME OF INSPECTION OBSERVED AT EXPOSURE# 2 PARTIAL DETACHMENT OF MASONRY LAMI
Page 1 of 1