Cases associated with NYC DOB UNSPECIFIED
461 distinct descriptions associated with this law label in the October 2026 enforcement extract. These are source allegations with educational draft analyses, not verified outcomes.
- Permit validity timeline · 39558552YSection UNSPECIFIED / OATH code 2P8 · OBSERVED SIDE WALK SHED ERECTED. UPON REVIEW SIDE WALK SHED PERMIT IS EXPIRED 07/28/2026 AND NO ACTIVE PERMIT IS ON FILE.
- Fire prevention or detection system · 39558597HSection UNSPECIFIED / OATH code 1N6 · UPON INSPECTION OF AN ACTIVE 2 STORY ALT CONSTRUCTION SITE WITH POTENTIAL FIRE HAZARDS. I OBSERVED NO FIRE EXTINGUISHERS INSTALLED
- Scaffold platform and fall protection · 39555840PSection UNSPECIFIED / OATH code 1P7 · BC 3314.1 ATOI, OBSERVED SUPPORTED SCAFFOLD INSTALLED AT EXP# 1 ON TOP OF THE SIDEWALK SHED, BUT NOT MAINTAINED AS PER CODE REQUIR
- Permit validity timeline · 39556289RSection UNSPECIFIED / OATH code 2P8 · AT TIME OF INSPECTION OBSERVED: SIDEWALK SHED IN PLACE AT EXPOSURE# 1 WITH PERMIT# B00077969-I1-SH UPON REVIEW DEPARTMENT RECORD I
- Scaffold platform and fall protection · 39557143ZSection UNSPECIFIED / OATH code 2P7 · AT TIME OF INSPECTION OF AN INACTIVE JOBSITE, OBSERVED A SUPPORTED SCAFFOLD NOT MAINTAINED IN A STABLE AND SECURE CONDITION, WITH
- Permit validity timeline · 39558650HSection UNSPECIFIED / OATH code 2P8 · AT THE TIME OF INSPECTION OF A 6-STORY MULTI-DWELLING, I OBSERVED AN ERECTED SIDEWALK SHED EXP1. A REVIEW OF DOB RECORDS DETERMINE
- Scaffold platform and fall protection · 39558792NSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF MY INSPECTION OBSERVED ACTIVE WITH IMPROPERLY INSTALLED SUPPORTED SCAFFOLD @ EXP. 3 MISSING MULTIPLE SAFETY COMPONE
- Unprotected openings and fall exposure · 39558791LSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE WITH WORKER NEAR INADEQUATE SHEAR CUT/SLOPE @ REARYARD WITHOUT A PROPER GUARDRAI
- Scaffold platform and fall protection · 39558648ZSection UNSPECIFIED / OATH code 1P7 · UPON INSPECTION I OBSERVED PIPE SCAFFOLD INSTALLED AND IN USE AT EXPOS 1 IN A UNSAFE MANNER CONTRARY TO CODE 3314.1 . INADEQUATE A
- Fire prevention or detection system · 35685987JSection UNSPECIFIED / OATH code 2P7 · CONTRACTOR FAILED TO PERFORM MONTHLY INSPECTION ON THE FIRE EXTINGUISHERS; 3301.1.2. REMEDY: COMPLY WITH CODE.
- Fire prevention or detection system · 39558679LSection UNSPECIFIED / OATH code 2N6 · OBSERVATION: ALL FIRE EXTINGUISHERS WITHOUT DATES. VIO FOR FAILURE TO MAINTAIN FIRE EXTINGUISHERS.MAINTAIN FIRE EXTINGUISHERS
- Permit validity timeline · 39558728ZSection UNSPECIFIED / OATH code 2P8 · AT THE TIME OF INSPECTION, I OBSERVED A SIDEWALK SHED ERECTED AT A 4-STORY MIX USE BUILDING. RESEARCH OF DOB NOW AND BIS RECORDS I
- Demolition, structural removal or excavation · 39558655RSection UNSPECIFIED / OATH code 2P7 · CBC 3304.4.5 & 3304.5.2 OBSERVED EXCAVATION WORK FOR SEWAGE DRAINAGE SYSTEM INSTALLATION. ATOI, APPROVED PERMIT & PLANS (HARD COPY
- Masonry or façade deterioration · 39558691YSection UNSPECIFIED / OATH code 2P7 · 26 STORY COMMERCIAL BUILDING ALT2 FACADE WORK ACTIVE SITE. FAILURE TO PROVIDE/PROTECT OCCUPANTS/COMPLY WITH REQUIRED OCCUPANT PROT
- Fire prevention or detection system · 39558765HSection UNSPECIFIED / OATH code 1N6 · UPON INSPECTION OF AN ACTIVE 7 STORY NB CONSTRUCTION SITE I OBSERVED FIRE EXTINGUISHERS SITTING ON THE FLOOR AND NOT PROPERLY INST
- Scaffold platform and fall protection · 39203031XSection UNSPECIFIED / OATH code 2P7 · OBSERVED SCAFFOLD MISSING GUARDRAIL RAIL SYSTEM,INADEQUATE WORKING PLATFORM AT VARIOUS LOCATIONS,FALL HAZARD CREATED LEADS INJURIE
- Permit validity timeline · 35729645LSection UNSPECIFIED / OATH code 2P8 · TEMP CONSTRUCTION EQUIP/INSTALLATION ON SITE EXPIRED PERMIT(SHED). AT THE TIME OF INSPECTION OBSERVED THERE IS NO ACTIVE PERMIT FO
- Scaffold platform and fall protection · 39558798YSection UNSPECIFIED / OATH code 2P7 · AT THE TIME OF INSPECTION, OBSERVED AT EXP1,AND3 UNSAFE SCAFFOLDING NOT IN COMPLIANCE WITH BC3314.1. MISSING TOE BOARDS, NOT TIED
- Masonry or façade deterioration · 39203029RSection UNSPECIFIED / OATH code 2P3 · OBSERVED THE PARTY WALL AT THE ADJOINING PROPERTY TO BE CRACKED AND LEANING, APPARENTLY DUE TO FAILURE TO PROPERLY PROTECT AND SUP
- Permit validity timeline · 35730178JSection UNSPECIFIED / OATH code 2P8 · EXPIRED SIDEWALK SHED PERMIT. AT THE TIME OF INSPECTION OBSERVED SIDEWALK SHED PERMIT #B01260885-I1-SH EXPIRED ON 07-28-2026, I CH
- Scaffold platform and fall protection · 39558683YSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE WITH UNPROTECTED POWERLINES NEAR ERECTED SUPPORTED [email protected]&2(3314.4.4.12)
- Sidewalk shed and public protection · 39556052ZSection UNSPECIFIED / OATH code 2L7 · AT THE TIME OF INSPECTION, A SIDEWALK SHED WAS OBSERVED INSTALLED AT EXPOSURE 1. REVIEW OF DEPARTMENT RECORDS INDICATES NO ACTIVE
- Masonry or façade deterioration · 39558681KSection UNSPECIFIED / OATH code 2P7 · 3309.9 WEATHERPROOF INTEGRITY OF ADJOINING BUILDINGS. AT TIME OF INSPECTION OBSERVED VOIDS IN THE BRICKS AND ROOF LEVEL OF THE ONC
- Scaffold platform and fall protection · 39558770MSection UNSPECIFIED / OATH code 1P7 · AT TIME OF INSPECTION, SITE WAS OBSERVED UTILIZING A PLATFORM/ PUMP JACK SCAFFOLD SYSTEM AT EXP 2. REQUIRED DRAWINGS FOR PLATFORM
- Permit validity timeline · 39558673KSection UNSPECIFIED / OATH code 2P8 · AT THE TIME OF INSPECTION, I OBSERVED A SIDEWALK SHED ERECTED AT A 14-STORY OCCUPIED BUILDING. RESEARCH OF DOB NOW AND BIS RECORDS
- Authorized use versus observed occupancy · 39202983ZSection UNSPECIFIED / OATH code 1N7 · FTP PROTECTION FOR TENANTS DURING DEMO OR CONSTRUCTION ACTIVITY IN AN OCCUPIED BUILDING.THE TPP REQUIRES THE CONTRACTOR TO INSTALL
- Roof and weather protection · 39558768NSection UNSPECIFIED / OATH code 2P4 · SITE WAS OBSERVED TO CONDUCT CONSTRUCTION OPERATIONS WITHOUT PROVIDING PROTECTION FOR THE ADJACENT ROOF OF THE NEIGHBORING PROPERT
- Fire prevention or detection system · 39558658MSection UNSPECIFIED / OATH code 1N6 · UPON INSPECTION I OBSERVED MISSING AND DEFECTIVE FIRE EXTINGUISHERS AT MULTIPLE LOCATIONS ON 1ST, 2ND, 3RD, 5TH FLOORS, ROOF, SETB
- Permit validity timeline · 39558675YSection UNSPECIFIED / OATH code 2P8 · DURING THE INSPECTION DOB RECORDS REVEALED THAT THE PERMIT FOR THE SIDEWALK SHED IN PLACE HAD AN EXPIRED PERMIT SINCE 06/25/2026 W
- Authorized use versus observed occupancy · 39558760ZSection UNSPECIFIED / OATH code 2P7 · UPON INSPECTION OF AN ACTIVE 7 STORY NB CONSTRUCTION SITE I OBSERVED STANDING WATER IN THE CELLAR FLOOR OF THE STRUCTURE AT A DEPT
- Sidewalk shed and public protection · 39558704YSection UNSPECIFIED / OATH code 2P8 · AT TIME OF INSPECTION OBSERVED 2 STORY BUILDING WITH SIDEWALK SHED INSTALLED AT EXP 1 WITH LIGHTING NOT MAINTAINED PER BC3307.6.4.
- Plumbing fixture and drainage configuration · 39558731JSection UNSPECIFIED / OATH code 1P7 · BC 3303.2.4-AT THE TIME OF INSPECTION OF AN ACTIVE CONSTRUCTION SITE, A FAILURE TO PROVIDE REQUIRED TOILET FACILITIES WAS OBSERVED
- Specific cited provision requiring manual cross-check · 39558723JSection UNSPECIFIED / OATH code 2P7 · AT TIME OF INSPECTION OBSERVED: CONTRACTOR USING A GENERATOR PART OF THE MECHANICAL EQUIPMENT TO PERFORM PILES/GROUNDING UPON REQU
- Unprotected openings and fall exposure · 39558638PSection UNSPECIFIED / OATH code 2P7 · OBSERVATION: (PAINTING,FLOORING) WALKED SITE. OBSERVED WORKER ON MAKESHIFT PLATFORM ABOVE OPEN STAIRCASE W/O FALL PROTECTION USING
- Specific cited provision requiring manual cross-check · 39558616YSection UNSPECIFIED / OATH code 2P7 · BC 3303.14-//WATER CONDITIONS-AT THE TIME OF MY INSPECTION I OBSERVED STANDING WATER IN CLOSE PROXIMITY TO EXP#2 DRIVEWAY/YARD(APP
- Fire prevention or detection system · 39558714HSection UNSPECIFIED / OATH code 2N6 · BC3303.7.2 & BC3301.1.2 OBSERVED: ACTIVE SITE UPON INSPECTION NOTED FIRE EXTINGUISHERS INADEQUATE NO TAGS,NO PINGS, NO EVIDENCE WH
- Scaffold platform and fall protection · 39558771YSection UNSPECIFIED / OATH code 2P7 · AT TIME OF INSPECTION, WORKERS WERE OBSERVED UTILIZING A PLATFORM/ PUMP JACK SYSTEM. THE WORKERS REQUIRED SAFETY LINE WERE OBSERVE
- Roof and weather protection · 39558677HSection UNSPECIFIED / OATH code 2P7 · OBSERVATION: NO HANDRAILS FOR STAIRCASES FROM 2ND FLOOR TO ROOF. HAZARDOUS CONDITION CAN CAUSE FATAL FALLS/INJURIES. VIO FOR NO HA
- Specific cited provision requiring manual cross-check · 39558721XSection UNSPECIFIED / OATH code 2P7 · AT TIME OF INSPECTION OBSERVED: INADEQUATE STORAGE ZONE TOTALLY ACCESSIBLE, INSIDE WITH MATERIALS, MECHANICAL EQUIPMENT NOT FULLY
- Authorized use versus observed occupancy · 35730971PSection UNSPECIFIED / OATH code 2Q8 · FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTIN
- Specific cited provision requiring manual cross-check · 39558812LSection UNSPECIFIED / OATH code 1M7 · ON AUGUST 5,2026 A WORKER SUFFERED A LACERATION ON THE LIP FALLING FROM LADDER AS PER DOB RECORD THE SITE FAILED TO NOTIFY DOB WIT
- Authorized use versus observed occupancy · 35730968YSection UNSPECIFIED / OATH code 2Q8 · FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTIN
- Permit validity timeline · 39558820LSection UNSPECIFIED / OATH code 2P8 · AT TIME OF INSPECTION OF 4 STORY MIXED USE BUILDING OBSERVED SIDEWALK SHED IN PLACE WITH PERMIT # M01223537 EXPIRED 9-1-26 CAUSING
- Scaffold platform and fall protection · 39558806PSection UNSPECIFIED / OATH code 1P7 · 3314.3.4 OBS. SUPPORTED SCAFFOLD ERECTED ON NEEDLE BEAMS & SIDEWALK SHED. REQ'D LOADS IMPOSED LETTER SIGNED/SEALED/DATED BY RDP WA
- Roof and weather protection · 39558821NSection UNSPECIFIED / OATH code 2P7 · AT TIME OF INSPECTION OBSERVED: SITE CLOSED, AT DEMOLITION STAGE. PSWO EXISTS ON THE PROPERTY. WHERE THE WEATHERPROOF INTEGRITY OF
- Street / sidewalk occupancy and dot authorization · 39558804LSection UNSPECIFIED / OATH code 2P7 · BC3307.2.1 AT TIME OF INSPECTION JERSEY BARRIERS OCCUPYING ROADWAY EXP# 1 AND EXP# 2. UPON REVIEWING DOT SYSTEM NO DOT PERMIT FOUN
- Regulatory report or inspection record · 39558832ZSection UNSPECIFIED / OATH code 1M7 · AN INCIDENT THAT OCCURRED ON 8/4/2026 AT THIS JOBSITE WHERE WORKER INJURED HIS FOREARM, UPON REVIEW OF DEPARTMENT RECORDS IT WAS R
- Authorized use versus observed occupancy · 35730969XSection UNSPECIFIED / OATH code 1Q3 · FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTIN
- Zoning, site use or regulated sign · 39558830PSection UNSPECIFIED / OATH code 2P7 · OBSERVATION: DOCUMENTS PROVIDED. UPON MY REQUEST FOR DESIGN/SHOP DRAWINGS OF TEMPORARY STAIRS NONE WAS PROVIDED. VIO FOR FAILURE T
- Scaffold platform and fall protection · 39558853HSection UNSPECIFIED / OATH code 2P7 · BC3314.8.2 AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD INSTALLED, AT EXP#1 #2 NOT MAINTAIN AS PER CODE DEBRIS NETTING LOOSE
- Specific cited provision requiring manual cross-check · 39558816ZSection UNSPECIFIED / OATH code 2P8 · FAILURE TO RENEW IS IN VIOLATION OF AC 28-105.2 (8) REGARDING THE USEOF TEMPORARY CONSTRUCTION EQUIPMENT. OWNER MUST RENEW PERMIT.
- Scaffold platform and fall protection · 39556400XSection UNSPECIFIED / OATH code 2P7 · 3314.1AT INSPECTION OF THE 7-STORY BUILDING UNDERGOING FACADE OPERATIONS, THE PIPE SCAFFOLD AT EXP. #4 WAS NOT MAINTAINED. MISSING
- Permit validity timeline · 39558852XSection UNSPECIFIED / OATH code 2P8 · AT TIME OF INSPECTION OBSERVED SIDEWALK SHED INSTALLED AT EXP# 1. UPON REVIEW IN DOB NOW AND BIS SYSTEM REVEALS TEMPORARY CONSTRUC
- Roof and weather protection · 39558744ZSection UNSPECIFIED / OATH code 2P7 · AT TIME OF INSPECTION, OBSERVED ADJOINING WALL OF 200 16TH STREET AT EXPOSURES 3 AND 4 NOT PROPERLY WEATHERPROOFED AND LEFT EXPOSE
- Scaffold platform and fall protection · 39558827YSection UNSPECIFIED / OATH code 2P7 · THE SUPPORTED SCAFFOLDING AT EXPOSURE 2 NOT MAINTAIN 3314.4.8COMPLY WITH CODE
- Authorized use versus observed occupancy · 35730970NSection UNSPECIFIED / OATH code 2Q8 · FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTIN
- Permit validity timeline · 39555832PSection UNSPECIFIED / OATH code 2P8 · . AT TIME OF INSPECTION, OCCUPIED 6-STORY BUILDING OBSERVED WITH SIDEWALK SHED AT EXPOSURE 1. SHED PERMIT #X01071144-I1-SH EXPIRED
- Scaffold platform and fall protection · 39558814PSection UNSPECIFIED / OATH code 1P7 · FAILURE TO COMPLY WITH BC3314.8 - 3314.9.4. OBSERVED SUPPORTED SCAFFOLD WITH LOSE AND UNSECURED DEBRIS NETTING ON SEVERAL LEVELS W
- Permit validity timeline · 39558813NSection UNSPECIFIED / OATH code 2P8 · AT THE TIME OF INSPECTION, I OBSERVED A SIDEWALK SHED ERECTED AT A 10-STORY MIX USE BUILDING. RESEARCH OF DOB NOW AND BIS RECORDS
- Fire prevention or detection system · 39202930PSection UNSPECIFIED / OATH code 1P7 · AT TIME OF INSPECTION OBSERVED AT 3RD FLOOR PROPANE TORCH WHERE NO FIRE EXTINGUISHER OBSERVED AT THIS FLOOR, FALL PROTECTION ( GUA
- Specific cited provision requiring manual cross-check · 39558817KSection UNSPECIFIED / OATH code 1M7 · FAILED TO NOTIFY THE DEPT OF A INCIDENT THAT RESULTED IN A FATALITY OR INJURY. AT TIME OF MY INSPECTION UPON REVIEWOF DEPT RECORDS
← Previous Page 6 of 6