Means of egress and exit protection: NYC DOB 28-301.1 / OATH summons 39137280Y
Original inspector allegation — verbatim available export
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: OBSERVED ACCORDING TO FILING #S007757787-P1 WHICH DEMONSTRATES THE 6FT REQUIRED CLEAR PATH FOR FIREFIGHTING OPERATIONS IS CURRENTLY BEING OBSTRUCTED BY INS
Source limit: Source reference: NYC OATH/DOB summons 39137280Y; BIN 5010444; export issue date 02/03/2025. The earlier export status was ACTIVE; obtain current status from DOB or OATH. The CSV contains a respondent mailing address, which is not presumed to identify the inspected property. This is the entire description available in the supplied export, not a certified full summons, inspector notes or evidentiary exhibits. The description is at the export’s approximately 210-character field limit and may terminate mid-word or mid-sentence.
Get the complete, authentic notice: search summons 39137280Y in OATH Summons Finder instructions (download actual summons) and download the actual summons; review DOB records in NYC DOB records search. Never substitute the editorial discussion below for the inspector’s words.
Charge classification: law controls; keywords do not
Recorded citation: 28-301.1; recorded infraction: 102. Primary legal issue: safe building maintenance. Interpretive issue: Owner maintenance obligation. AC 28-301.1 requires buildings, equipment, safeguards and means of egress to be kept safe and maintained. The physical condition, rather than whether a particular permit exists, is normally the central question.
What must be tested: The applicable underlying technical standard and the actual defective component determine a lawful repair. An assertion that the building is generally safe does not rebut a specific defect.
Possible exceptions and legal limitations: An exemption from cyclical façade reporting does not exempt a building from general safe-maintenance duties. Determine whether the special rule actually applies. Eligibility is not established merely because the excerpt uses a word such as “repair”, “permit”, “cellar”, or “occupied”. Refer to NYC DOB construction codes.
Specific conditions mentioned in this inspector wording
1. Means of egress and exit protection
Investigative test: Trace the occupant route from the cited point to discharge; check door swing, clear width, obstruction, illumination and the approved layout.
Evidence matched to this issue: Approved egress plan, location-labeled photos and measured clearance, fire/exit inspection records, dated removal or hardware repair evidence.
Boundary / potential counterexample: Do not advise blocking an occupied egress route as a temporary fix; applicability may differ for old and altered buildings.
Inspector wording mapped to testable facts
Passage 1 — FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: OBSERVED ACCORDING TO FILING #S007757787-P1 WHICH DEMONSTRATES THE 6FT…
This recorded passage identifies a question about means of egress and exit protection, not a proven final determination. Trace the occupant route from the cited point to discharge; check door swing, clear width, obstruction, illumination and the approved layout. Do not advise blocking an occupied egress route as a temporary fix; applicability may differ for old and altered buildings.
Identifiers, locations, measurements and chronology to verify
- Stated dimensions: 6FT
- Re-measure in the field, show the measurement origin on an annotated photo and compare the relevant code threshold.
Case-specific correction decision tree
Branch A — defect remains: assess risk and protection immediately, then undertake an appropriate licensed/engineered repair. Branch B — already repaired: pair before/after photos with scope, inspection and test results that address the *specific* defect. Branch C — inspector misidentified the component: use an elevation/floor key and technical field report; do not rely on an unspecific clean-inspection assertion.
First targeted evidence collection: Approved egress plan, location-labeled photos and measured clearance, fire/exit inspection records, dated removal or hardware repair evidence. This is an investigative request, not a claim that the work or evidence already exists.
Editorial closure of the shortened allegation — NOT source text
Verbatim excerpt ends: “DEMONSTRATES THE 6FT REQUIRED CLEAR PATH FOR FIREFIGHTING OPERATIONS IS CURRENTLY BEING OBSTRUCTED BY INS”. Non-source editorial completion (conditional reconstruction, not a quotation): “The allegation appears to concern means of egress and exit protection; whether additional observations, directions, dates, measurements or exceptions followed is unknown and must be checked in the original summons.”
No missing words, dates, measurements, liability conclusion or regulatory remedy have been invented. Even if the final syllable looks obvious, completing it as a purported inspector quotation would misstate an official record.
Response, certification and closing evidence
A hearing defense, correction of the underlying condition, a DOB AEU Certificate of Correction and payment of an imposed penalty are distinct questions. Retrieve the summons and confirm the OATH hearing or outcome and DOB violation status. Under current DOB guidance, Certificate of Correction review requests are made in DOB NOW: Safety → Violations & Notices of Deficiency; submitter/certifier signatures and evidence requirements are case-specific. Refer to Certificate of Correction instructions.
Source record limitations: The dataset does not authenticate who inspected the property, why inspection started, whether a defense succeeded, which contractor made repairs or whether AEU later accepted a correction. Do not turn this example into a claimed client success story or an invented inspection history.
Primary authority and fact-check links
- OATH Summons Finder instructions (download actual summons) — enter summons 39137280Y and obtain the signed notice.
- NYC DOB construction codes — verify law wording and any exception.
- BIS / DOB NOW record limitations — older BIS violations may not be in DOB NOW.
- Certificate of Correction instructions — review current COC procedure, signatures and evidence.
Related library and official records
Official sources: Search DOB records · DOB summonses · Certificate of Correction FAQs · OATH hearing options · Construction codes
Need a resolution plan tied to the full summons?
Building Violation LLC can review the violation wording, permits, drawings, correction evidence and available OATH hearing procedures. A web example is not a determination of compliance for any property.