Examples under OATH infraction code 182
61 distinct enforcement-description examples carrying this infraction code. Check the actual summons before interpreting the code.
- Departure from approved construction documents · 39558892KSection 28-105.12.2 / OATH code 182 · @ACTIVE 7STORY NB SITE UP TO 5TH FL OBSERVE STRUCTURAL FRAME OF COLD FORM STEEL PERIMETER WALL&I REQUEST MOST UPDATED&APPROVED STR
- Authorized use versus observed occupancy · 39194872ZSection 28-105.12.2 / OATH code 182 · AT THE TIME OF INSPECTION, OBSERVED SISTERED JOISTS THROUGHOUT ALL STORIES AND SHORING WERE OBSERVED AT THE CELLAR AND NO APPROVED
- Plumbing fixture and drainage configuration · 39203422NSection 28-105.12.2 / OATH code 182 · WORK DOES NOT CONFORM TO THE DOB APPROVED PLANS Q01192392-I1. OBSERVED AT THE TIME OF INSPECTION AT CELLAR LEVEL UNPERMITTED 2 WAT
- Departure from approved construction documents · 39558951LSection 28-105.12.2 / OATH code 182 · OBS. TEMP LOADING PLATFORM >78' HIGH INSTALLED CONTRARY TO APPROVED ENGINEERED DRAWINGS. FIELD CONFIGURATION, INCL. DIAGONAL/X-BRA
- Masonry or façade deterioration · 39558985JSection 28-105.12.2 / OATH code 182 · OBSERVED: SWS PARAPET REPLACEMENT WORK IN PROGRESS AT EXP #1,#2,& #4 CONTRARY TO APPROVED PLANS. NOTED CORNER EXP1-4 INTERIOR COVE
- Departure from approved construction documents · 39558986LSection 28-105.12.2 / OATH code 182 · NOTED: SWS ERECTED ON EXP 1,4 CONTRARY TO APPROVED DRAWINGS NO EXTENDED AT EXP 4,& MISSING LIGHTS UNDER IT
- Means of egress and exit protection · 39558982YSection 28-105.12.2 / OATH code 182 · SUPPORT OF EXCAVATION.OBSERVE SITES EXCAVATION OPERATIONS NOT CONFORM TO PLANS AFFECTING HEALTH&LIFE SAFETY-EXP#2 EXCAVATION SHEAR
- Structural and interior building component · 39558946RSection 28-105.12.2 / OATH code 182 · ATOI IN RESPONSE TO AN INCIDENT THAT OCCURRED ON 9/8 WHERE AN EXCAVATOR FELL THROUGH 1ST FLOOR TO GRADE RESEARCH OF DEPARTMENTAL R
- Means of egress and exit protection · 39558970RSection 28-105.12.2 / OATH code 182 · UPON INSPECTION OF A ACTIVE 4 STORY NB AND AFTER REVIEW OF THE SITE SAFETY LOGISTICS PLAN A SAFE MEANS OF EGRESS SHOULD BE PROVIDE
- Roof and weather protection · 39558947ZSection 28-105.12.2 / OATH code 182 · I OBSERVED ENTIRE BUILDING CURRENTLY AT 1ST FLOOR LEVEL CONTRARY TO MECHANICAL DEMOLITION PLANS EQ-115.00 & 116.00. THE MIDDLE POR
- Structural and interior building component · 39559042ZSection 28-105.12.2 / OATH code 182 · AT THE TIME OF MY INSPECTION OF A 10 STORY NEW BUILDING AT 5 FLOOR DECKING LEVEL, UPON REVIEW OF THE CONSTRUCTION SAFETY WAIVER IT
- Structural and interior building component · 39204012PSection 28-105.12.2 / OATH code 182 · AT EXP 3 A TWO STORY STAIR CASE FROM SECOND FLOOR BEING BUILT DOES NOT CONFORM TO THE APPROVED PLANS. AT SECOND FLOOR THERE IS AN
- Windows, doors and openings · 39166653KSection 28-105.12.2 / OATH code 182 · OBSVD WORK AS BUILT AT EXP 1 DOESNT CONFORM TO APPVD PLANS. PLANS SHOW 1 ENTRY DOOR AND 1 WINDOWS AT F1ST FL. AS BUILT THERE ARE 2
- Sidewalk shed and public protection · 39559179JSection 28-105.12.2 / OATH code 182 · AT THE TIME OF INSPECTION I OBSERVED WORKERS INSTALLING OVERHEAD PROTECTION ON EXPOSURE #3. UPON REVIEWING THE DOB APPROVED DOCUME
- Zoning, site use or regulated sign · 39559176YSection 28-105.12.2 / OATH code 182 · AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE WITH ERECTED STEEL @ MULTILPE LOCATIONS. SITE STRUCTURAL STEEL WORK IS CONTRARY
- Demolition, structural removal or excavation · 39204151PSection 28-105.12.2 / OATH code 182 · TIE BACKS WERE INSTALLED ON EXPOSURE 2 PARTY WALL. THIS WORK WAS NOT APPROVED TO BE DONE AS PER STABILIZATION AND IS PART OF THE P
- Scaffold platform and fall protection · 39559218NSection 28-105.12.2 / OATH code 182 · ATOI OBSERVED A SYSTEMS SCAFFOLD IN UNIT 1 FROM THE CELLAR TO THE 5TH FLOOR IN THE ELEVATOR SHAFT WHEN ASKED FOR SCAFFOLDING DRAWI
- Demolition, structural removal or excavation · 39559232JSection 28-105.12.2 / OATH code 182 · AT INSPECTION, WORKERS WERE PERFORMING FOOTING WORK IN 12-FT AND 14-FT DEEP EXCAVATIONS AT EXPOSURES 3 AND 4 IN THE REAR. WORK WAS
- Windows, doors and openings · 39557004ZSection 28-105.12.2 / OATH code 182 · 14 STORY INTERIOR DEMO, ACTIVE SITE OBSERVED WORK CONTRARY TO SSP/3309.10. INADEQUATE ROOF PROTECTION OF ADJOINING PROPERTY EXP#1,
- Departure from approved construction documents · 39558569KSection 28-105.12.2 / OATH code 182 · OBSERVED: FENCE ERECTED ON PERIMETER SITE ,UPON REVIEW DRAWINGS NOTED IT CONTARY TO DRAWINGS ON CORNER EXP1&2 AND 1&4 / OR AMENDED
- Departure from approved construction documents · 39559355JSection 28-105.12.2 / OATH code 182 · SITE SAFETY PLAN.OBSERVE ACTIVE SITE IN SUPERSTRUCTURE PHASE UP TO 10TH FL WORKING DECK&UPON REVIEW OF PROVIDED SITE SAFETY PLAN W
- Departure from approved construction documents · 39202656LSection 28-105.12.2 / OATH code 182 · ATOI OBSERVED ALTERATIONS TO EXTERIOR OF ALL EXPOSURES DOES NOT CONFORM TO APPROVED PLANS EXISTING ELEVATION & SECTIONS JOB# B0090
- Departure from approved construction documents · 39559275JSection 28-105.12.2 / OATH code 182 · OBSERVED: CS PRESENT, STRUCTURAL STEEL FRAIMING GOING ON 2ND AND 3RD LEVEL UPON VISUAL INSPECTION NOTED THERE MISSING BOLTS, PLACE
- Traffic barriers and worksite separation · 39548337MSection 28-105.12.2 / OATH code 182 · YODOCK SYSTEM IN PLACE INSTEAD OF THE REQUIRED JERSEY BARRIER SYSTEM REQUIRED IN THE APPROVED PLANS. REPLACE YODOCK SYSTEM OR AMEN
- Authorized use versus observed occupancy · 39541643ZSection 28-105.12.2 / OATH code 182 · AT THE TIME OF INSPECTION OF A 2-STORY ALT BUILDING WITH INTERIOR DEMOLITION AT THE BASEMENT LEVEL, IT WAS OBSERVED THAT FIVE STRU
- Roof and weather protection · 39186383HSection 28-105.12.2 / OATH code 182 · WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. NOTED; AT ROOF LEVEL DECK IS COMPOSED OF FLAM
- Masonry or façade deterioration · 39181184MSection 28-105.12.2 / OATH code 182 · ATOI, OBSERVED AT ROOF LEVEL OF PREMISES. STEEL PIPE RAILING INSTALLED ON PARAPET WALL ON ALL EXPOSURES, CONTRARY TO PLAN AS PER F
- Windows, doors and openings · 39173598MSection 28-105.12.2 / OATH code 182 · OBSERVED AT EXP 1 WINDOWS CONTRARY TO APPROVED PLANS. HOUSE HAD 4 WINDOWS AND CURRENTLY HAS 2. PLANS DO NOT REFLECT THE CHANGES IN
- Departure from approved construction documents · 39558554HSection 28-105.12.2 / OATH code 182 · THE SOE DRAWING DOES NOT CORRESPOND WITH THE ACTUAL STATE OF THE OF THE SAID STRUCTURE AS SHOWN IN THE PHOTOS PROVIDED. STOP ALL W
- Wall / exterior structural condition · 39557680YSection 28-105.12.2 / OATH code 182 · AT TIME OF INCIDENT FOLLOW UP INSPECTION, SHORING AND SUPPORT WORK WAS IN PROGRESS FOR THE ADJACENT PROPERTY EXTERIOR WALL AT EXP
- Sidewalk shed and public protection · 39549763JSection 28-105.12.2 / OATH code 182 · SIDEWALK SHED INSTALLED NOT IN ACCORDANCE WITH APPROVED DRAWINGS. OBSERVED MISSING REQUIRED 5-FT EXTENSION, PARAPET SIGNAGE PANELS
- Demolition, structural removal or excavation · 39146174PSection 28-105.12.2 / OATH code 182 · WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. RESPONDING TO A COLLAPSE OF BUILDING AT EXP#1
- Structural and interior building component · 39183790LSection 28-105.12.2 / OATH code 182 · OBSERVED WORK NON CONFORMING TO APPRVD PLANS ON PERMITTED (JOB#M01158579) FLOORS 2,4,5. FL 2 STORAGE RM DELETED. NEW WALL AND DOOR
- Electrical installation and permit · 39154738LSection 28-105.12.2 / OATH code 182 · WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. NOTED; BUILDING OBSERVED BEING CHANGED FROM O
- Authorized use versus observed occupancy · 39175501XSection 28-105.12.2 / OATH code 182 · OBSERVED, THE FOLLOWING ARE CONTRARY TO THE DRAWINGS: AT CELLAR EXPOSURE 4 NEW OPENING INSTALLED, VERTICAL ENLARGEMENT OF EXISTING
- Wall / exterior structural condition · 39173109MSection 28-105.12.2 / OATH code 182 · ATOI OBSERVED 100% OF 2 STORY HOME DEMOED. ALL EXTERIOR WALLS HAVE BEEN REMOVED WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOC
- Scaffold platform and fall protection · 39555208LSection 28-105.12.2 / OATH code 182 · 1 STORY ALT1 ACTIVE SITE.OBSERVED WORK CONTRARY TO PLANS ONSITE,CELLAR MISSING PIPE SCAFFOLD SHORING UNDER WOOD FLOOR JOIST. MAKES
- Structural and interior building component · 39558349ZSection 28-105.12.2 / OATH code 182 · AT TIME OF INSPECTION OBSERVED A PROPOSED 8 STORY BUILDING NOT CONFORMING TO APPROVED DOCUMENTS OR WAIVER . ALL 3 BUILDINGS ON PRO
- Demolition, structural removal or excavation · 39558355PSection 28-105.12.2 / OATH code 182 · AT TIME OF INSPECTION, OBSERVED BUILDINGS B AND C HAD BEEN FULLY DEMOLISHED WHILE BUILDING A REMAINED, CONTRARY TO THE APPROVED DE
- Sidewalk shed and public protection · 39558290NSection 28-105.12.2 / OATH code 182 · BC 3307.4.7 TEMPORARY PUBLIC WALKWAY: I OBSERVED AT THE STORAGE WORK ZONE AREA WITH A SIDEWALK SHED IN PLACE WAS MISSING THE REQUI
- Authorized use versus observed occupancy · 39558377XSection 28-105.12.2 / OATH code 182 · AT TIME OF INSPECTION OBSERVED STRUCTURAL WORK STEAL BEAM IN PLACE AT CELLAR LEVEL SUPPORTING FIRST FLOOR. STAIRS ARE INSTALLED ON
- Demolition, structural removal or excavation · 39558436RSection 28-105.12.2 / OATH code 182 · OBS. ACTIVE EXCAVATION AT BOTH LOT LINES CONTRARY TO APPROVED SOE. REQ'D PERIMETER SOE PER B-E/SOE-202 NOT INSTALLED AS EXCAVATION
- Authorized use versus observed occupancy · 39558463MSection 28-105.12.2 / OATH code 182 · Q01424052.@PERMITTED&ACTIVE SITE OBSERVE WORK NOT CONFORM TO PLANS COMPROMISING STRUCTURAL STABILITY&AFFECTING HEALTH&LIFE SAFETY
- Demolition, structural removal or excavation · 39558478PSection 28-105.12.2 / OATH code 182 · OBS. 1-SIDED FNDN WALL FORM/SHORING NONCONFORMING TO RDP DETAIL 16/FW-005. STEEL-PIPE/TIMBER BRACES ENDED LOOSE ON SLAB/WOOD; NEIT
- Departure from approved construction documents · 39558396LSection 28-105.12.2 / OATH code 182 · DURING THE INSPECTION OF A 9STORY NB AT AN ACTIVE JOB SITE, IT WAS OBSERVED THAT TIMBER SOLDIER POSTS WITH 3 INCH TIMBER LAGGING,
- Authorized use versus observed occupancy · 39558412MSection 28-105.12.2 / OATH code 182 · AT TIME OF INSPECTION OF 6 STORY MIXED USE BUILDING OBSERVED WORK BEYOND APPROVED PLANS WITH COMPLETE GUT RENOVATION (FLOORS, WALL
- Demolition, structural removal or excavation · 39558511HSection 28-105.12.2 / OATH code 182 · AT TIME OF INSPECTION I OBSERVED EXCAVATION BEING CONDUCTED. UPON REVIEW OF DOB APPROVED PLANS WORK DOES NOT CONFORM TO APPROVED P
- Demolition, structural removal or excavation · 39558515PSection 28-105.12.2 / OATH code 182 · AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE WITH REMOVAL/ NEWLY INSTALLED WOOD JOISTS @ FLOORS 1,2,3,&4. UPON REQUEST NO TEM
- Permit validity timeline · 39202398HSection 28-105.12.2 / OATH code 182 · PERMIT #B01009942 EXPIRED 12/19/2025 ON FILE. HOWEVER, ATOI OBSERVED BALCONY ON 3RD FLOOR, EXPO.1, EXTENDED TO APRX. 10 FT X 9 FT,
- Scaffold platform and fall protection · 39558635JSection 28-105.12.2 / OATH code 182 · DURING THE INSPECTION OF THE ACTIVE 8-STORY NB, IT WAS OBSERVED THAT THE PIPE SCAFFOLD/ENGINEERED ENCLOSURE AT EXPOSURE 2 IS NOT I
- Structural and interior building component · 39202665NSection 28-105.12.2 / OATH code 182 · ATOI, OBSERVED 2-STORY BUILDING WITH ACTIVE PERMIT #B01357954-I1-GC. WORK OBSERVED DOES NOT CONFORM TO APPROVED PLANS, INCLUDING 1
- Structural and interior building component · 39202649NSection 28-105.12.2 / OATH code 182 · WORK DOES NOT CONFORM TO APPROVED CONST. DOC. AND/OR APPROVED AMENDMENTS. OBSERVED APPROVED DRAWINGS FOR JOB# M01360788-I1-SC HAS
- Demolition, structural removal or excavation · 39558566PSection 28-105.12.2 / OATH code 182 · OBSERVED: ACTIVE SITE UPON INSPECTION SAW EXCAVATION DONE FOR HORIZONTAL EXTENSION, REVIEW DRAWINGS PLANS FOUND: NO SOLDIER PILES
- Zoning, site use or regulated sign · 39202669KSection 28-105.12.2 / OATH code 182 · WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/ OR AMENDMENTS; NOTE JOB APPLICATION X01285374 SHOWS NO WORK TO BE DO
- Authorized use versus observed occupancy · 39202667RSection 28-105.12.2 / OATH code 182 · ATOI, OBSERVED 2-STORY BUILDING WITH ACTIVE PERMIT #B01357954-S1-PL. WORK OBSERVED DOES NOT CONFORM TO APPROVED PLANS, INCLUDING R
- Scaffold platform and fall protection · 39558795ZSection 28-105.12.2 / OATH code 182 · DURING THE INSPECTION OF THE ALTERATION TO THE 17 STORY BUILDING, OBSERVED SUSPENDED SCAFFOLDS @EXP#1 TIE BACKS WHERE ATTACHED TO
- Structural and interior building component · 39202836ZSection 28-105.12.2 / OATH code 182 · OBSERVED AN ADDITIONAL LEVEL ADDED WITH A BALCONEY AT EXP 3 SUGGESTING A 3RD FLOOR. WORK IS CONTRARY TO APPROVED PLANS AND BEYOND
- Authorized use versus observed occupancy · 39558689PSection 28-105.12.2 / OATH code 182 · STRUCTURAL FRAMING WORK AND TEMPORARY SHORING CONTRARY TO APPROVED DRAWINGS. OBSSERVED AT BASEMENT LEVEL,DIGING ONE FEET CONTRARY
- Departure from approved construction documents · 39558657KSection 28-105.12.2 / OATH code 182 · OBSERVED: FENCE WORK CONTRARY TO APPROVED DOCUMENTS FENCE ,ON SITE ERECTED ONLY EXP2&4 FRONT SIDE ., CONTRARY TO DRAWINGS A001.00
- Departure from approved construction documents · 39203120HSection 28-105.12.2 / OATH code 182 · WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. ATOI, I OBSERVED AT EXP 1 A WOOD AWNING APPRO
- Scaffold platform and fall protection · 39558805NSection 28-105.12.2 / OATH code 182 · OBS. EXCESSIVE SCAFFOLD FRAMES, PIPES, LUMBER & MISC. MATERIAL STORED/STACKED ON SIDEWALK SHED DECK, CONTRARY TO APPROVED RDP PLAN