- Safe building maintenance · 39202309RSection 28-301.1 / OATH code 202 · ATOI OBSERVED PVC USED OUTSIDE THE KITCHEN AREA ON A WASTE STACK ALSO WITH RUBBER JIM CAPS. IN THE LAUNDRY ROOM ALL PVC ON WASTE F
- Elevator device maintenance and safety devices · 39202112NSection 28-301.1 / OATH code 251 · CLAS 2 ITEMS: IN-CAR EMERGENCY COMMUNICATION DEVICE IS NOT CONNECTED TO A CONTINUOUSLY STAFFED LOCATION AS REQUIRED BY APPENDIX K.
- Plumbing fixture and drainage configuration · 39202248MSection 28-301.1 / OATH code 202 · OBSERVED IN THE BATHROOM SINK DRAIN LINE, PVC PIPING CONNECTED TO THE DRAIN WHICH IS PROHIBITED AS PER NYC PC 701.9, ALSO USAGE OF
- Elevator device maintenance and safety devices · 39202240HSection 28-301.1 / OATH code 251 · CLASS 2 ITEMS: IN-CAR EMERGENCY COMMUNICATION HAS VERY LOW/INAUDIBLE RESPONDING VOICE; REPAIR. ASME A17.1/CSA B44 2.27.1. TOP-OF-C
- Windows, doors and openings · 39201918HSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT INCIDENT AT EXPOSURE 1(FRONT) BETWEEN 3 &
- Sidewalk shed and public protection · 39202057JSection 28-301.1 / OATH code 102 · ATOI OBSERVED SIDEWALK SHED WITH DETERIORATED DECKING, DISPLACED PROTECTIVE PANELS AND UNSECURED PORTIONS OF THE OVERHEAD ENCLOSUR
- Masonry or façade deterioration · 39201964ZSection 28-301.1 / OATH code 102 · AGGRAVATED CONDITIONS OBSERVED AT TODAY'S INSPECTION, CONSISTENT WITH VIOLATION #39155126P ISSUED 7/28/2025 FOR FAILURE TO MAINTAI
- Elevator safety and service status · 39202238ZSection 28-301.1 / OATH code 151 · FAILURE TO MAINTAIN ELEVATOR IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. AS PER NYC BUILD
- Safe building maintenance · 39202085RSection 28-301.1 / OATH code 251 · CLASS 2 ITEMS: EXCESSIVE CLEARANCE OBSERVED ON THE RETURN SIDE OF CAR DOOR. THE MEASURED GAP MAXIMUM ALLOWABLE LIMIT. PROPER DOOR
- Elevator safety and service status · 39176912PSection 28-301.1 / OATH code 151 · CLASS 1 RTS: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSP
- Roof and weather protection · 39202295PSection 28-301.1 / OATH code 202 · I OBSERVED AT TIME OF INSPECTION IN FRONT OF BUILDING ON SIDEWALK WATER LEAKING ONTO THE SIDEWALK FROM BUILDING WHICH IS PROHIBITE
- Authorized use versus observed occupancy · 39202013HSection 28-301.1 / OATH code 202 · OBSERVED PROPERTY BACKYARD SEWAGE FLOODING FROM AN UNMAINTAINED DRAIN LINE, VIOLATING NYC PC 102.3. ALSO, PROHIBITED UNSHIELDED FE
- Roof and weather protection · 39202509LSection 28-301.1 / OATH code 126 · ATOI OBSERVED DOOR TO ROOF WITH SLIDE BOLT HARDWARE INSTALLED AND A DOUBLE SIDE KEY LOCK AT BASMENT DOOR, PROVIDE LEGAL HARDWARE
- Masonry or façade deterioration · 39202564YSection 28-301.1 / OATH code 102 · FACADE AND PARAPET LEVEL IN DISREPAIR. MISSING MORTAR THROUGHOUT AND UNDER CAPPING STONES. WALLS BOWING THROUGHOUT. PARAPET LEVEL
- Masonry or façade deterioration · 39202673NSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION OBSERVED VERTICAL STEP CRACKS THAT LEAD FROM THE FIFTH FLOOR TO PARAPET WALL. AT EXP 1 & 2. VIOLATION #39166
- Zoning, site use or regulated sign · 39202187HSection 28-301.1 / OATH code 302 · FAILURE TO MAINTAIN BUILDING IN A COMPLIANT MANNER CODE. AT TIME OF INSPECTION NOTED; AT FRONT (EXP. 1) TWO SIDEWALK CURB CUT. ONE
- Safe building maintenance · 39202235NSection 28-301.1 / OATH code 251 · VF... MACHINE ROOM NO MEANS OF ACCESS PROVIDE MEANS OF ACCESS..2.7.3.3... COMMUNICATION DEFECTIVE REPAIR... 2.7.8.4.A..
- Safe building maintenance · 39202371HSection 28-301.1 / OATH code 102 · FAILURE TO TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT THE TIME OF INSPECTION OBSERVED AT EXPOSURE #1 MULTIPLE A/C UN
- Fire prevention or detection system · 39202607PSection 28-301.1 / OATH code 102 · AT THE TIME OF INSPECTION OBSERVED LACK OF SPRINKLER COVERAGE IN HALLWAYS ON 2ND & 3RD FLOORS SOFFITS WERE ADDED WHERE SPRINKLER H
- Masonry or façade deterioration · 39202507HSection 28-301.1 / OATH code 102 · ATOI OBSERVED MULTIPLE STEP CRACKS THROUGHOUT THE FACADE SPALLING BRICKS AT EXPOSURE #1 EAST 138ST, REPAIR AND/REPLACE
- Elevator safety and service status · 39202262ZSection 28-301.1 / OATH code 151 · CLASS 1 ITEM: HOISTWAY SWING DOORS AT FLOORS 5 AND 6 NOT OPERATING PROPERLY. FLOOR 6 DOOR WOULD OPEN APPROXIMATELY 3 INCHES AND GE
- Structural and interior building component · 39202449ZSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, I OBSERVED 2 WATER STAINED CEILING TILE INSIDE THE
- Means of egress and exit protection · 39202555MSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ATOI FOR VIO#39182386P ATOI OBSERVER AT EXP#1&2 AND COURT YARD AC UNITS WIT
- Masonry or façade deterioration · 39202598MSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING EXTERIOR FACADE. AT TIME OF INSPECTION, OBSERVED AT EXPOSURE 4 WALL A VERTICAL CRACK EXTENDING THE FU
- Elevator safety and service status · 39202426XSection 28-301.1 / OATH code 151 · CLASS 1 (CU)FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPE
- Windows, doors and openings · 39194043LSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED DAMAGED FLOOR MOLDING, A VERTICAL CRACK IN
- Masonry or façade deterioration · 39202479JSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED VERTICAL, HORIZONTAL, AND STEP CRACKS AT
- Elevator safety and service status · 39202343KSection 28-301.1 / OATH code 151 · CEASE USE ITEM: EMERGENCY PHONE AND EMERGENCY ALARM BELL ARE INOPERATIVE, PREVENTING REQUIRED EMERGENCY COMMUNICATION AND SIGNALIN
- Masonry or façade deterioration · 39202729NSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION OBSERVED STOOP AT FRONT OF THE BUILDING HAVE CRACKS OUT OF PLUMB, TREADS SHIFTED, BRICKS DAMAGED AND FALLING
- Masonry or façade deterioration · 39202572YSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION OBSERVERED VARIOUS CRACKS ON FACADE AT EXPOSURE # 1 AND #3 AND IN DISREPAIR CONDITION ALSO #39082384N ISSUED
- Electrical installation and permit · 39202642KSection 28-301.1 / OATH code 102 · AR EXP 3 OBSERVED GARAGE MISSING ROOF AND DOOR LEAVING APPROX 8' HIGH FREESTANDING MASONRY WALLS. POTENTIAL FOR WALL TO FALL OVER
- Electrical installation and permit · 39202430ZSection 28-301.1 / OATH code 102 · WORK WITHOUT A PERMIT. I OBSERVED ELECTRICAL OUTLETS, SWITCHES AND CEILING LIGHTS INSTALLED IN THE FIRST FLOOR RECREATION ROOM. NO
- Elevator safety and service status · 39202614NSection 28-301.1 / OATH code 151 · UPON INSPECTION, THE BUILDING'S ONLY ELEVATOR WAS FOUND OUT OF SERVICE AND HAS REMAINED INOPERATIVE FOR SEVERAL MONTHS, DEPRIVING
- Elevator safety and service status · 39202254ZSection 28-301.1 / OATH code 151 · CLASS 1 RTS:FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER PASSENGER ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSP
- Masonry or façade deterioration · 39202372JSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT THE TIME OF INSPECTION OBSERVED VERTICAL AND HORIZONTAL CRACKS TH
- Elevator safety and service status · 39202237RSection 28-301.1 / OATH code 251 · 1) THE PHONE IS NOT WORKING (RC)(8.11.2.1.1). 2) THE LIGHT IN THE MOTOR-ROOM IS BROKEN (ALSO THE BULB IS NOT BRIGHT ENOUGH) (8.11.
- Elevator safety and service status · 39202124KSection 28-301.1 / OATH code 151 · VF... R T S.. ... 97-X-17.. ELEVATOR IN BUILDING OUT OF SERVICE . UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE CREATIN
- Scaffold platform and fall protection · 39202657NSection 28-301.1 / OATH code 102 · ATOI OBSERVED SUPPORTED PIPE SCAFFOLD IN PLACE WITH A MESH WRAPPED AROUND IT WHICH IS NOT IN COMPLIANCE WITH THE BUILDING CODE (BC
- Authorized use versus observed occupancy · 39194941NSection 28-301.1 / OATH code 102 · NOTED: VIOLATION ISSUED FOR FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER DUE TO EXCESSIVE DEBRIS. ATOI OBSERVED AN EXCESS
- Fire prevention or detection system · 39202513YSection 28-301.1 / OATH code 155 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER: LACK OF AN AUTOMATIC SPRINKLER SYSTEM WHERE REQUIRED PER BC 903.2; 27-954
- Scaffold platform and fall protection · 39202457ZSection 28-301.1 / OATH code 102 · OBSERVED MULTIPLE STAIRWELL DOORS NOT MAINTAINED, DOORS AT ROOF NOT ABLE FULLY OPEN, AC WITHOUT BRACKET ABOVE ENTRY AT EXPO 1, PAR
- Authorized use versus observed occupancy · 39202167KSection 28-301.1 / OATH code 202 · OCCUPANCY CONTRARY TO THAT ALLOWED BY THE COFO. OR D.O.B RECORDS. COFO. #241328 INDICATES BUILDING ON 2ND FLOOR AS OFFICES USE. AT
- Roof and weather protection · 39202413RSection 28-301.1 / OATH code 202 · ATOI OBSERVED DOORWAYS AT THE 1ST FLOOR LOBBY LEVEL LEADING TO THE STAIRWELL AND ROOF ARE DISLODGED, MISALIGNED, AND NOT FLUSH WIT
- Masonry or façade deterioration · 39202683RSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT EXPOSURE 1(FRONT) FLOORS 1-4 STEP CRACKS,
- Plumbing fixture and drainage configuration · 39202654HSection 28-301.1 / OATH code 139 · ATOI OBSERVED ONGOING PLUMBING WORK UNDER PERMIT #B01005008, EXP. 03/30/2027, LIMITED TO SMALL PORTION OF CELLAR CEILING AT EXPO.2
- Means of egress and exit protection · 39163949XSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION - GROUND FLOOR/BSMT APT OBSERVED WITH OBSTRUCT
- Masonry or façade deterioration · 39202525LSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION, INSPECTOR ON DUTY NOTICED SEVERAL VERTICAL AND HORIZONTAL CRACKS AND LOOSE BRICK AT EXP 1, REPAIR AND/REPLA
- Elevator device maintenance and safety devices · 39202263KSection 28-301.1 / OATH code 251 · MAIN LINE ELEVATOR DISCONNECT HANDLE IS MISSING AND THE ENTIRE DISCONNECT NEEDS TO BE REPLACED. ASME A17.1 2.7.3 - DISCONNECTING M
- Masonry or façade deterioration · 39202637XSection 28-301.1 / OATH code 102 · ATOI OBSERVED MULTIPLE STEP CRACKS, DETERIORATED MORTOR JOINT, SPALLING BRICKS AT EXPOSURE#1(EAST 6 STREET), REPAIR AND/REPLACE
- Plumbing fixture and drainage configuration · 39202473ZSection 28-301.1 / OATH code 102 · ATOI OBSERVED HOT WATER HEATER ON THE ROOF INSTALLED WITH NO DISCHARGER PIPING INSTALLED COMING OUT OF THE PRV CONTRARY TO PC 504.
- Safe building maintenance · 39202493XSection 28-301.1 / OATH code 151 · A17.1 2.1.4.7.1 WHEN A CAR IS OUTSIDE THE UNLOCKING ZONE THE CAR DOORS SHALL BE SO ARRANGED THAT WHEN IN THE CLOSED POSITION THEY
- Zoning, site use or regulated sign · 39202127XSection 28-301.1 / OATH code 202 · RCA ISSUED 03/18/25 TO SAME RESPONDENT & NOT CORRECTED FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER AT REAR ADJACENT TO LEGAL
- Safe building maintenance · 39202466KSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HOLE PENETRATIONS, (PLASTIC ACCESS PANELS) .LOCATED THROUGHOUT THE
- Authorized use versus observed occupancy · 39200385JSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED, 2FAMILY HOUSE CELLAR STAIR HAS NO HANDRAIL
- Elevator safety and service status · 39202236PSection 28-301.1 / OATH code 251 · 1) THE PHONE IS NOT WORKING (RC)(8.11.2.1.1). 2) THE LIGHT IN THE MOTOR-ROOM IS NOT BRIGHT ENOUGH (8.11.2.1.2). 3) THE BRASS GEAR
- Elevator device maintenance and safety devices · 39197676PSection 28-301.1 / OATH code 151 · CLASS 1 ITEMS: CEASE USE: DOOR RESTRICTOR INOPERATIVE. IN VIOLATION OF ASME A17.1-2013 2.14.5.7 AND 2.14.4.2. CONDITION EXPOSES TH
- Zoning, site use or regulated sign · 39196413ZSection 28-301.1 / OATH code 302 · FAILURE TO MAINTAIN BUILDINGS IN CODE COMPLIANT MANNER: ILLEGAL OFF STREET PARKING MAINTAINED WITHOUT DOB APPROVAL CONTRARY TO ZR
- Street / sidewalk occupancy and dot authorization · 35733231NSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. SUBJECT IS A 2-STORY ON A CORNER LOT WITH COMMERCIAL USE OCCUPANCY. EXP.
- Elevator device maintenance and safety devices · 39202510ZSection 28-301.1 / OATH code 251 · CLASS 2 ITEMS: CAR LIGHTING IS INSUFFICIENT. NYC IDENTIFICATION NUMBER IS NOT DISPLAYED ON THE MAIN CAR OPERATING PANEL. REQUIRED
- Electrical installation and permit · 39202279PSection 28-301.1 / OATH code 251 · 1) THE TELEPHONE IS NOT WORKING (8.11.2.1.1). 2) THE HANDRAIL IS LOOSE. THE LIGHTS IN THE CAR ARE NOT GUARDED (8.11.2.1.1). 3) THE
- Unprotected openings and fall exposure · 39202519PSection 28-301.1 / OATH code 202 · ATOI OBSERVED STAIRCASE CONSTRUCTED W/O PERMIT, NOT EQUIPPED WITH REQUIRED GUARDRAIL SERVING MAIN ENTRY OF OCCUPIED BLDG. ALSO OBS
- Zoning, site use or regulated sign · 39196412RSection 28-301.1 / OATH code 302 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: ATOI OBSERVED ON AVE X AND EAST 14 ST, 3 SIDEWALK CURB CUT AT FRONT OF THE
- Masonry or façade deterioration · 39202726HSection 28-301.1 / OATH code 202 · NOTED AT THE TIME OF INSPECTION, AT EXPOSURE #1, FRONT FACADE OF THE PROPERTY ALONG 32ND STREET, A BRICK PLANTER BOX WAS OBSERVED
- Authorized use versus observed occupancy · 39202524JSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. PREMISES IS A 5 STORY M/D IN APARTMENT 1I FIRST FLOOR REAR BEDROOM HAVE M
- Safe building maintenance · 39202537ZSection 28-301.1 / OATH code 251 · SHORTEN HOIST ROPES.(8.6.3.1.2.). MISALINGED CAB MIRROR (BC 3001.2.). PROVIDE SELF LOCKING SELF CLOSING DOOR (2.7.3.4.1(A)). UNLAB
- Plumbing fixture and drainage configuration · 39202406ZSection 28-301.1 / OATH code 202 · ATOI OBSERVED ON 2ND FLOOR OPEN WATER LINES AND WASTE LINE NOT PROPERLY CAPPED. PER PC 102.3 MAINTENANCE INSTALLATIONS BOTH EXISTI
- Boiler device inspection and filing · 39194411XSection 28-301.1 / OATH code 254 · FOUND DUNKIRK GAS FIRED BOILER, MODEL # PWB-7D WITH EXPOSED WIRING., MAINTAIN BOILER; REPLACE COVERS ON CONTROLS ETC
- Zoning, site use or regulated sign · 39202735JSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION OBSERVED FRONT, SIDE, & REAR YARD OF PREMISES
- Elevator device maintenance and safety devices · 39202492YSection 28-301.1 / OATH code 251 · CLASS 2 ITEMS: PROVIDE ELEVATOR DOOR TO OPEN FULLY AND SMOOTHLY, PER 28-304.1. IN-CAR EMERGENCY COMMUNICATION INOPERATIVE, PER ASM
- Zoning, site use or regulated sign · 39202338XSection 28-301.1 / OATH code 202 · RCA ISSUED 04/01/25 TO SAME RESPONDENT & NOT CORRECTED FAILURE TO MAINTAIN BLDG LOT 28-301.1, ILLEGAL CURB CUT CREATED W/OUT DOB A
- Street / sidewalk occupancy and dot authorization · 35733230LSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. SUBJECT IS A 3-STORY ON A CORNER LOT WITH STORE BUILDING USE. EXP 1 IS AL
- Masonry or façade deterioration · 39202640RSection 28-301.1 / OATH code 202 · ATOI OBSERVED NO WORK IN PROGRESS, NOTICED SEVERAL CRACKS AT EXP 4 OF THE PROPERTY, APPROX LENGTH OF CRACKS PROPAGATING UPWARDLY I
- Elevator device maintenance and safety devices · 39202655JSection 28-301.1 / OATH code 251 · CLASS 2: 1. MAINTENANCE LOG - LOG BOOK HAS NO RECORDS, FAILING REQUIRED DOCUMENTATION. AS PER ASME A17.1 8.6. REMEDY: PROVIDE COMP
- Gas equipment or fuel piping · 39202529ZSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN, I OBSERVED IN CELLAR, METER ROOM USED FOR STORAGE AND SLEEPING QUARTERS, AS PER APPENDIX E 3.3 GAS METER ROOM
- Roof and weather protection · 39202266XSection 28-301.1 / OATH code 302 · FAILURE TO MAINTAIN BUILDING AND ALL PARTS THEREOF IN A CODE COMPLIANT MANNER . NOTED : AT TIME OF INSPECTION,OBSERVED AT EXPOSURE
- Elevator safety and service status · 39202503KSection 28-301.1 / OATH code 251 · RTS CLASS 2: UPON INSPECTION, ONE OF TWO ELEVATORS SERVING THE BUILDING WAS FOUND OUT OF SERVICE AND NOT AVAILABLE FOR PASSENGER U
- Gas equipment or fuel piping · 39202411NSection 28-301.1 / OATH code 202 · RCA WAS ISSUED ON 6/29/2026 WITH THE CORRECTION DATE 8/28/2026, FAILURE TO MAINTAIN. I OBSERVED THE USE OF A PROHIBITED UNION ON G
- Masonry or façade deterioration · 39202373LSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT INTERIOR HALLWAY 4TH FLOOR & BULKHEAD CEI
- Safe building maintenance · 39202596ZSection 28-301.1 / OATH code 202 · OBSERVED NO HAND RAILING AT THE FRONT STEPS AND NO HAND RAILING/PROTECTIVE GUARDS RAILING AT THE PORCH CREATING A FALL HAZARD AT T
- Masonry or façade deterioration · 39202554KSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER NOTED: AT TIME OF INSPECTION OBSERVED BROKEN/DEFECTIVE/MISSING FIREPROOF C