- Windows, doors and openings · 35718726JSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. I OBSERVED HAZARDOUS CONDITION WITH THE EXTERIOR WALL OF THE BUILDING. AT V
- Zoning, site use or regulated sign · 39202629XSection 28-301.1 / OATH code 302 · FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. NOTED; AT TIME OF INSPECTION, OBSERVED CURB CUT CREATED APPROXIMATELY 7 F
- Safe building maintenance · 39202536RSection 28-301.1 / OATH code 202 · RCA ISSUED 05/13/25 TO SAME RESPONDENT & NOT CORRECTED FAILURE TO MAINTAIN BLDG CODE-COMPLIANT FRONT FENCE IN DISREPAIR SOME PORTI
- Elevator device maintenance and safety devices · 39202470NSection 28-301.1 / OATH code 251 · CLASS2 ITEMS: PROVIDE PHON IN CAR ASME A17.1-2013 SECTION 2.27.1.1 EMERGENCY COMMUNICATIONS REQUIRED, 3- BRAKE TAGE EXPIRE AND CAT
- Means of egress and exit protection · 39202711PSection 28-301.1 / OATH code 202 · THE DOOR PROVIDING ACCESS TO THE STAIRWAY(SECOND MEANS OF EGRESS) WAS OBSERVED TO BE DIFFICULT TO OPEN DUE TO THE DOOR NOT BEING P
- Elevator device maintenance and safety devices · 39192982KSection 28-301.1 / OATH code 151 · CEASE USE: CONTROLLER FUSE(S) HAVE BEEN BYPASSED/JUMPED, DEFEATING OVERCURRENT PROTECTION AND CREATING AN UNSAFE OPERATING CONDITI
- Elevator device maintenance and safety devices · 39202312HSection 28-301.1 / OATH code 251 · CLASS2 ITEMS: PHONE INOPERATIVE ASME A17.1-2013 SECTION 2.27.1.1 EMERGENCY COMMUNICATIONS REQUIRED, 2-PROVIDE ACCESS 2 FLOOR, 2 FL
- Safe building maintenance · 39202587RSection 28-301.1 / OATH code 202 · I OBSERVED MULTIPLE FLEX HOSES ILLEGALLY USED TO CONNECT HOUSE PIPING TO UTILITY SERVICE AFTER METER WAS REMOVED. AS PER FGC 411.1
- Elevator device maintenance and safety devices · 39202286NSection 28-301.1 / OATH code 251 · CLASS 2 ITEMS: PROVIDE WORKING PHONE NUMBER TO CONTACT SUPERINTENDENT AT LOBBY FLOOR. PROVIDE ACCESS TO ELEVATOR MACHINE ROOM. BC
- Elevator device maintenance and safety devices · 39202399JSection 28-301.1 / OATH code 251 · CLASS 2 ITEMS: IN-CAR EMERGENCY COMMUNICATION INOPERATIVE, IN VIOLATION OF ASME A17.1 2.27.1.1, AS MODIFIED BY NYC BC APPENDIX K.
- Elevator device maintenance and safety devices · 39195269ZSection 28-301.1 / OATH code 251 · CLASS 2: IN-CAR EMERGENCY COMMUNICATION DEVICE IS INOPERATIVE AND NOT CONNECTED TO A LOCATION STAFFED BY AUTHORIZED PERSONNEL. ROU
- Elevator device maintenance and safety devices · 39202491MSection 28-301.1 / OATH code 251 · CLASS2 ITEMS: PROVIDE MISSING UP HALL BUTTON IN LOBBY ASME A17.1 E-15.1-E-15.5) BRAKE TAGE EXPIRE AND CAT1 TAGE EXPIRE PER A17.1 ,
- Zoning, site use or regulated sign · 39202730KSection 28-301.1 / OATH code 302 · AT TIME OF INSPECTION OBSERVED FAILURE TO MAINTAIN EXCESSIVE AMOUNT OF COMBUSTIBLE WOOD CONSTRUCTION DEBRIS, TRASH WHICH EXCESSED
- Safe building maintenance · 39202301MSection 28-301.1 / OATH code 202 · RCA ISSUED 03/31/25 RESPONDENT HAS ATTEMPTED TO REPAIR FENCE HOWEVER UPON REINSPECTION IN VARIOUS AREAS SHARP EDGE METAL & NAILS E
- Elevator safety and service status · 39202062YSection 28-301.1 / OATH code 251 · CLASS 2 ITEMS: ELEVATOR STOPPED ABOVE FLOOR LEVEL IN LOBBY, CREATING A TRIPPING HAZARD AT THE LANDING. ADJUST FLOOR LEVELING AND M
- Means of egress and exit protection · 39202745NSection 28-301.1 / OATH code 102 · ATOI OBSERVED AIR-CONDITIONED S IN BASKETS OF FIRE ESCAPE ANOTHER WITHOUT SUPPORT BRACKETS AT EXPOSURE #1 OF ABOVE PREMISES; IMPEE
- Safe building maintenance · 39202790MSection 28-301.1 / OATH code 251 · 98-BB-05 EXPIRE CAT 5, PERFORM & FIE TEST, CAR PHONE INOPERATIVE REPAIR, CLEAN CAR TOP & PIT. STOP SWTICH IN PIT RUSTED & DAMAGED
- Structural and interior building component · 35733188RSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. I OBSERVED PARTLY DISCONNECTED VINYL SIDING ALONG THE FRONT ELEVATION/EXPOS
- Structural and interior building component · 39202955LSection 28-301.1 / OATH code 151 · CEASE USE ITEM : INOPERATIVE ZONE LOCK RESTRICTOR (2.14.5.7.1.). CLASS 2 ITEMS: SHORTEN GOVERNOR ROPE (8.6.3.1.2.). UNREADABLE MAI
- Authorized use versus observed occupancy · 39202904LSection 28-301.1 / OATH code 102 · FTM BLDG WALL(S) OR APPURTENANCES. OBSVED AT EXPO 2 AT ALLEYWAY FIRE RATED WALL AT EXISTING DWELLING UNIT HAS AN OPENING APPROX 4F
- Safe building maintenance · 39202985MSection 28-301.1 / OATH code 226 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8(2014 CODE); BC 101
- Elevator safety and service status · 39202750HSection 28-301.1 / OATH code 151 · CLASS1 ITEM: ELEVATOR STUCK ON 4 FLOOR, RTS FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER, SERVICE ELEVATOR EQUIPMENT AS P
- Boiler device inspection and filing · 39202862MSection 28-301.1 / OATH code 354 · PEERLESS BOILER NOT LEGALLY ABANDONED+PERMIT 320967593 IS EXPIRED WITHOUT SIGNOFF;CORRECT VIOLATION+SUBMIT CERTIFICATE OF CORRECTI
- Masonry or façade deterioration · 39202810KSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. FACADE EXP 1,2,3 HAS STEP/VERTICAL CRACKS, MISSING BRICK/MORTAR. SHARED DRI
- Elevator device maintenance and safety devices · 39202917KSection 28-301.1 / OATH code 251 · REPLACE OR SECURE GIBS WHERE NEEDED (2.11.11.5.7.). MISALINGED CAB MIRROR (BC 3001.6). PROVIDE DESIGNATED LOBBY BRAILLE TAGS. (ADA
- Fire prevention or detection system · 39202967ZSection 28-301.1 / OATH code 102 · ATOI OBSERVED IN THE BASEMENT LACK OF SPRINKLER COVERAGE IN A OPEN AREA ROOM CONTAINING GARBAGE BINSBC 903.3.3 OBSTRUCTED LOCATION
- Authorized use versus observed occupancy · 39202969MSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HOLE PENETRATIONS AND PLASTIC ACCESS PANELS, WHICH ARE NOT RATED.
- Safe building maintenance · 39202670HSection 28-301.1 / OATH code 151 · CLASS I MISSING DLM 3,10,12 APPK PROVIDE, CAR PHONE INOPERATIVE REPAIR, UP TO DATE LOG BOOKS PROVIDE,
- Electrical installation and permit · 39202875LSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION - LOOSE & HANGING ELECTRICAL LINES WERE OBSERV
- Windows, doors and openings · 39202988HSection 28-301.1 / OATH code 102 · FTM: AT THE TIME OF INSPECTION, OBSERVED ENTIRE STRUCTURE IN SEVERE DETERIORATED AND UNSAFE CONDITION. ROOF WITH LARGE SECTIONS OP
- Authorized use versus observed occupancy · 39202931RSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT APARTMENT 20A, WATER PENETRATION HAS DAMA
- Masonry or façade deterioration · 39202851RSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN INTERIOR WALLS, CEILINGS AND EXTERIOR FACADE. AT TIME OF INSPECTION, OBSERVED CRACKED CEILINGS WITH EVIDENCE O
- Electrical installation and permit · 39202780ZSection 28-301.1 / OATH code 202 · NOTED AT THE TIME OF INSPECTION, EXPOSED AND UNCOVERED ELECTRICAL WIRES WERE OBSERVED AT THE CEILING FAN LOCATIONS IN APARTMENT 1L
- Zoning, site use or regulated sign · 39202798RSection 28-301.1 / OATH code 251 · REPLACE OR SECURE GIBS WHERE NEEDED (2.11.11.7.5.). PROVIDE IN CASE OF FIRE SIGNS WHERE NEEDED (BC 3002.3.). MISALINGED CAB MIRROR
- Elevator safety and service status · 39202740YSection 28-301.1 / OATH code 151 · CLASS 1 ITEMS: ELEVATOR REMAINS OUT OF SERVICE FOR AN EXTENDED PERIOD AND HAS NOT BEEN RESTORED TO OPERATION. PREVIOUSLY CITED CON
- Masonry or façade deterioration · 39202927YSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION OBSERVED AT EXP#2 MISSING MORTAR JOINTS AT MULTIPLE LOCATIONS, CRACKS ON FACADE AT EXP#1 AND 2, AT EXP# 4 PA
- Structural and interior building component · 39202902HSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED THE CEILING WITH WATER DAMAGE IN MULTIPLE LO
- Boiler device inspection and filing · 39202325RSection 28-301.1 / OATH code 254 · FOUND GAS BOILER CROWN MODEL 16H-340, 340000 BTUS, WITH MULTIPLE VIOLATING CONDITIONS. GAS METER WAS SHUT OFF AND LOCKED BY UTILTY
- Masonry or façade deterioration · 35718653HSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. PROPERTY IS AN ATTACHED 1 STORY HEALTH CENTER LOCATED ON AN INTERIOR LOT.
- Windows, doors and openings · 39202934MSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION OBSERVED AT EXP#1 FIRE ESCAPE ACCESS FROM APARTMENT PARTIALLY OBSTRUCTED BY WINDOW MOUNTED AC UNITS., REPAIR
- Elevator device maintenance and safety devices · 39202695YSection 28-301.1 / OATH code 251 · VF... HOIST MACHINE BRAKE TAG UPDATE MISSING PROVIDE...8.6.4.6....
- Safe building maintenance · 39202490KSection 28-301.1 / OATH code 151 · 1) THE ALARM BELL AND THE STOP BUTTON ARE NOT WORKING (8.11.1.5)(CU) 2) THE PHONE IS NOT WORKING (8.11.2.1.1). 3) THE MIRROR IN TH
- Authorized use versus observed occupancy · 39202906PSection 28-301.1 / OATH code 202 · ATOI OBSERVED FAILURE TO MAINTAIN AT REAR YARD BALCONY. OBSERVED BRICKS IN DISREPAIR AND CRACKED WALL. ALSO OBSERVED STORM DRAIN N
- Means of egress and exit protection · 39202858JSection 28-301.1 / OATH code 126 · AT TIME OF INSPECTION OBSERVED ILLEGAL HARDWARE ON DOORS ACCESSING THE MAIN STAIRWAY, INCLUDING SLIDE LATCH AND KEYED LOCK, RESTRI
- Windows, doors and openings · 39202766MSection 28-301.1 / OATH code 102 · ATOI OBSERVED EXCESSIVE DEBRIS @ EXPO 3. CONSISTING OF AIR COMPRESSOR, LADDERS, SAW, OLD WINDOWS, SCREENS AND A STEEL WINDOW GATE.
- Elevator safety and service status · 39202543PSection 28-301.1 / OATH code 251 · (RTS) AN ELEVATOR IN SECTION OF BUILDING OR BUILDING IS OUT-OF-SERVICE. UPON INSPECTION THE DEVICE IS FOUND TO BE OUT-OF-SERVICE C
- Windows, doors and openings · 39202932ZSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION OBSERVED FIRE ESCAPE ACCESS FROM APARTMENTS AT FRONT OF THE BUILDING PARTIALLY OBSTRUCTED BY WINDOW MOUNTED
- Roof and weather protection · 39202720RSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT 1ST FLR COMMON HALLWAY - 1. CEILING OPENING OBSERVED APPRX 4' X 4
- Masonry or façade deterioration · 39202746PSection 28-301.1 / OATH code 202 · CRACKS WERE OBSERVED IN THE MASONRY FACADE AND MASONRY STAIRWAY. SPALLING MASONRY AND DETERIORATED/RUSTED METAL COMPONENTS WERE AL
- Masonry or façade deterioration · 39202477XSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED APPROX. 4' HIGH MASONRY RETAINING WALL WI
- Roof and weather protection · 39202859LSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION OBSERVED MULTIPLE MISSING STAIR SPINDLES, STAIRCASE PITCHED, LOOSE/HANGING SHEETROCK THROUGHOUT TWO FLOORS,
- Elevator safety and service status · 39202392RSection 28-301.1 / OATH code 151 · 1) THERE IS A FUSE JUMPED OUT (CU) (8.11.1.5). 2) THE ELEVATOR DOES NOT LEVEL PROPERLY (DYNAMIC BRAKING)(CU TEST WITH WEIGHTS{125%
- Means of egress and exit protection · 39203025JSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT HALLWAY LANDING PARTIAL OBSTRUCTIONS OBSE
- Safe building maintenance · 39202952XSection 28-301.1 / OATH code 226 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8 (2014 CODE). AT TI
- Elevator safety and service status · 39202791YSection 28-301.1 / OATH code 151 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER AS PER BC3001.2 & 27-987 UPON AN INSPECTION THE ELEVATOR IS FOUND TO BE OUT
- Elevator safety and service status · 39202585NSection 28-301.1 / OATH code 151 · FAILURE TO MAINTAIN ELEVATOR IN BUILDING CODE COMPLIANT AS PER BC3001.2 & 27-987 CLASS 1: EMERGENCY COMMUNICATION IS FOUND INOPERA
- Windows, doors and openings · 39203003ZSection 28-301.1 / OATH code 202 · AT TIME OF INSPECTION, OBSERVED 10INCH DUCT WORK FROM COMMERCIAL SPACE TERMINATING ONTO PUBLIC SIDEWALK DIRECTLY BELOW THE FIRE ES
- Means of egress and exit protection · 39202986YSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN PARTIALLY UNOBSTRUCTED SECOND MEANS OF EGRESS. AT TIME OF INSPECTION, OBSERVED FLOWER POTS AND MISCELLANEOUS I
- Elevator device maintenance and safety devices · 39202809NSection 28-301.1 / OATH code 151 · CEASE USE ITEMS: (1) DOOR ZONE RESTRICTOR INOPERATIVE, CREATING A HAZARDOUS CONDITION PER 1RCNY11-02. ITEM (2) WATER INTRUSION OBS
- Safe building maintenance · 39202792XSection 28-301.1 / OATH code 151 · CEASE USE ITEM: INOPERATIVE ZONE LOCK RESTRICTOR (2.14.5.7.1.). CLASS 2 ITEMS : INOPERATIVE ALARM BELL (5.6.1.25.). REPLACE OR SEC
- Roof and weather protection · 39202738PSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION OBSERVED STAIR CASE FROM 4 FLOOR TO ROOF LEVEL STRINGER DISLODGED, TREAD DISPLACED AND STAIRCASE IN DANGER T
- Masonry or façade deterioration · 39194541YSection 28-301.1 / OATH code 102 · DISREPAIR AT ALL PARAPETS LEVEL AND EXPOSURE'S #4 FACADE. BRICKS ARE MISSING/DELAMINATING/SEPARATING WITH MORTAR MISSING ALL THROU
- Safe building maintenance · 39202844ZSection 28-301.1 / OATH code 251 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REMEDY: RESTORE
- Windows, doors and openings · 39202839YSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ATOI I OBSERVED AT FRONT CEILING/ROOF LEVEL ,PIECES OF SOFFIT FALLING APART
- Elevator device maintenance and safety devices · 39202964NSection 28-301.1 / OATH code 151 · FAILURE TO MAINTAIN ELEVATOR IN BC COMPLIANT AS PER BC3001.2 & 27-987. CLASS 1 (05-A-10) CEASE USE ITEM: DOOR ZONE RESTRICTOR HAS
- Elevator safety and service status · 39202485XSection 28-301.1 / OATH code 151 · FAILURE TO MAINTAIN ELEVATOR IN CODE COMPLIANT AS PER BC3001.2 & 27-987 UPON AN INSPECTION THE ELEVATOR IS FOUND OUT OF SERVICE, C
- Windows, doors and openings · 39202933KSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION OBSERVED AT EXP#1 FIRE ESCAPE ACCESS FROM 2ND FLOOR APT. PARTIALLY OBSTRUCTED BY WINDOW MOUNTED AC UNIT. ALS
- Zoning, site use or regulated sign · 39202597KSection 28-301.1 / OATH code 251 · MISALIGNED CAB MIRROR (BC 3001.2). PROVIDE FIRE RATED DOOR FOR MACHINE SPACE (NFPA). MACHINE DOOR UNLOCKED/MISALIGNED (2.7.3.4.1(A
- Safe building maintenance · 39202824LSection 28-301.1 / OATH code 126 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8; 27-371(J). NOTED: A
- Elevator safety and service status · 39202863YSection 28-301.1 / OATH code 251 · 1) CLEANING OF COMBUSTABLE MATERIALS IN ELEATOR PIT. 2) PROVIDE ACCESST TO MR FOR PROPER ELEVATOR INSPECTION. 3) SECURE IN CAR VIS
- Fire prevention or detection system · 39202776XSection 28-301.1 / OATH code 102 · AT THE TIME OF INSPECTION OBSERVED THROUGH OUT THE BUILDING PAINTED SPRINKLER CAPS, MISSING CAPS & PAINTED SPRINKLER HEADS WHICH I
- Elevator safety and service status · 39202901XSection 28-301.1 / OATH code 151 · (RTS) THE ONLY ELEVATOR IN SECTION OF BUILDING OR BUILDING IS OUT-OF-SERVICE. UPON INSPECTION THE DEVICE IS FOUND TO BE OUT-OF-SER
- Safe building maintenance · 39202954JSection 28-301.1 / OATH code 251 · SHORTEN GOVERNOR ROPE (8.6.3.1.2.).
- Plumbing fixture and drainage configuration · 39202774MSection 28-301.1 / OATH code 102 · AT THE TIME OF INSPECTION OBSERVED THE HOT WATER HEATERS IN THE MAIN HOT WATER HEATER ROOM ON THE ROOF INSTALLED WITH PVC PIPING O
- Masonry or façade deterioration · 39202929HSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION, INSPECTOR OBSERVED MULTIPLE CRACKS AT EXP 1. ALSO OBSERVED DAMAGE TO GARAGE AREA WALL/OPENING, REPAIR AND/R
- Gas equipment or fuel piping · 39202775YSection 28-301.1 / OATH code 202 · AT THE TIME OF INSPECTION OBSERVED GAS PIPING ON ROOF NOT PAINTED OR LABELED IN ACCORDANCE TO . FGC 401.5 - IDENTIFICATION REQUIRE
- Elevator safety and service status · 39202442XSection 28-301.1 / OATH code 151 · FAILURE TO MAINTAIN ELEVATOR IN BUILDING CODE COMPLAINT AS PER BC3001.2 & 27-987. CLASS 1 RTS: UPON AN INSPECTION THE ELEVATOR IS
- Windows, doors and openings · 35718654JSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. PROPERTY IS AN ATTACHED 3+C MIXED USE DWELLING LOCATED ON A CORNER LOT. O
- Elevator device maintenance and safety devices · 39202896KSection 28-301.1 / OATH code 151 · CEASE USE ITEM: DOOR ZONE RESTRICTOR UPON INSPECTION THE DOOR ZONE RESTRICTOR IS NOT WORKING ON TOP CAR ,AS PER ASME A17.1-2013 2.
- Boiler device inspection and filing · 39202741XSection 28-301.1 / OATH code 254 · FOUND EASCO SM4-200 DUAL FUEL BOILER WITH LEAKING SAFETY RELIEF VALVE, AND SMOKE ALARM BULB ON BREECHING NOT OPERABLE.