Cases associated with NYC DOB 28-301.1
1,428 distinct descriptions associated with this law label in the October 2026 enforcement extract. These are source allegations with educational draft analyses, not verified outcomes.
- Means of egress and exit protection · 39204255JSection 28-301.1 / OATH code 138 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER; LACK OF EMERGENCY LIGHTING FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS
- Masonry or façade deterioration · 39203921HSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER : NOTED : AT EXPOSURE #1 ON RETAINING WALL AN APPROX . 10 FT STEP CRACK WITH
- Fire prevention or detection system · 39204092YSection 28-301.1 / OATH code 202 · ATOI OBSERVED PAINTED SPRINKLER HEADS IN THE STAIRWAYS, ALSO THEY ARE MISSING ESCUTCHEONS CONTRARY TO BC 903.3.3 OBSTRUCTED LOCATI
- Elevator device maintenance and safety devices · 39203850JSection 28-301.1 / OATH code 251 · INOPERATIVE CAR PHONE (2.27.1.1.3.). MISALINGED CAB MIRROR (BC 3001.6). ILLEGIBLE CAR STATION DEVICE NUMBER. PLANK SWITCH ACTIVATE
- Structural and interior building component · 39204244YSection 28-301.1 / OATH code 139 · ATOI OBSERVED PREMISES IS 1 STORY STORE BUILDING MISSING FIRESTOPPING, FAILURE TO PROVIDE/MAINTAIN REQUIRED FIRESTOPPING. OBSERVED
- Elevator safety and service status · 39203849MSection 28-301.1 / OATH code 151 · CEASE USE ORDER: UNPROTECTED OPENING IN THE CAR ENCLOSURE ABOVE THE COP OPENS DIRECTLY INTO THE HOISTWAY. CLASS 2 ITEMS: KEY-SWITC
- Windows, doors and openings · 39204204JSection 28-301.1 / OATH code 202 · DUE TO ONGOING DEMOLITION WORK AT ROOF & TOP FLOOR OF BLDG. MULTIPLE PORTIONS OF ROOF, INTERIOR WALLS & WINDOWS AT TOP FLOOR REMOV
- Structural and interior building component · 39195867ZSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN. ATOI AT A 2.75 WALK OBSERVED STRUCTURAL WOOD ROT IN THE SECOND-FLOOR LOAD-BEARING STRUCTURAL GIRDER DIRECTLY
- Elevator device maintenance and safety devices · 39204263JSection 28-301.1 / OATH code 251 · CL TOP OF CAR LIGHTING INOPERATIVE. ILLUMINATION SHOULD BE PROVIDED ON TOP OF THE CAR. ASME A17.1-2013 2.14.7.1.1. ASS 2 ITEMS: AC
- Masonry or façade deterioration · 39153294PSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER; OBSERVED BALCONY AT EXP 1 IN STATE OF DISREPAIR. LOOSE BRICKS SEPARATING FR
- Elevator safety and service status · 39204153ZSection 28-301.1 / OATH code 151 · FAILURE TO MAINTAIN ELEVATOR IN BUILDING CODE COMPLIANT AS PER BC3001.2 & 27-987. UPON AN INSPECTION THE ELEVATOR IS FOUND TO BE O
- Authorized use versus observed occupancy · 39204133LSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDINGS IN CODE COMPLIANT MANNER: ATOI ACCESS TO CELLAR SEWERS BACK UP CREATES HAZARD CONDITIONS FOR TENANTS
- Safe building maintenance · 39203944KSection 28-301.1 / OATH code 251 · VF.. CAT 5 TAG MISSING PROVIDE,,8.6.4.5..MAINTENANCE LOG UPDATE MISSING PROVIDE...8.6.1.4...
- Means of egress and exit protection · 39204345NSection 28-301.1 / OATH code 202 · ATOI OBSERVED FAILED TO MAINTAIN A CLEAR EXIT PATH NEAR THE COMPACTOR ROOM. APPROXIMATELY 50 FULL GARBAGE BAGS BLOCKED THE EXIT PA
- Plumbing fixture and drainage configuration · 39196289KSection 28-301.1 / OATH code 102 · IN BASEMENT APARTMENT D, IN BATHROOM,CEILING HAS COLLAPSED. IN APARTMENT ABOVE 1E BATHROOM FLOOR SAGS., REPAIR AND/REPLACE; VACATE
- Structural and interior building component · 39163416NSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. A TIME OF INSPECTION OBSERVED EXISTING WOOD STAIRCASE IN A STATE OF DISREPA
- Gas equipment or fuel piping · 39204455YSection 28-301.1 / OATH code 102 · OBSERVED AT APT #D1 AT 4TH FLOOR GAS WORK DUE STOVE WAS REMOVED WHOLES LINE TO STOVE WAS CUT OFF AND NOT CAPED VALVE APPEARS TO BE
- Safe building maintenance · 39204417NSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING CODE COMPLIANT. NOTED: THE FRONT CORNICE IS IN DISREPAIR. AT THE RIGHT SIDE THERE IS A HOLE IN THE BO
- Authorized use versus observed occupancy · 39204132JSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDINGS IN CODE COMPLIANT MANNER: ATOI OBSERVED AT CELLAR REAR DOOR LEFT TO OPEN CREATES ACCESSIBLE FOR VERM
- Gas equipment or fuel piping · 39204423JSection 28-301.1 / OATH code 102 · ATOI OBSERVED ON THE ROOF GAS PIPING NEEDING TO BE MAINTAINED SOME PARTS NOT PAINTED ALSO SOME PARTS RUSTED. GAS PIPE MUST BE PROP
- Fire prevention or detection system · 39204121YSection 28-301.1 / OATH code 251 · 1) THE CAT-1 TAG IS EXPIRED (8.11.1.6). 2) THE FIRE EXTINGUISHER TAG IS EXPIRED (8.11.1.6). 3) THE A/C IS LEAKING ONTO THE WALL (C
- Boiler device inspection and filing · 39204316YSection 28-301.1 / OATH code 202 · RCA WAS ISSUED ON 7/13/2026 WITH CORRECTION DATE 9/11/2026, I OBSERVED IN THE CELLAR BOILER ROOM THE USE OF A BUSHING ON GAS PIPIN
- Elevator safety and service status · 39202972NSection 28-301.1 / OATH code 151 · CLASS 1 RESTORE TO SERVICE: ELEVATOR REMAINS OUT OF SERVICE AT THE TIME OF REINSPECTION. PREVIOUSLY CITED CONDITION REMAINS UNCORR
- Zoning, site use or regulated sign · 39161763ZSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION AT FRONT YARD LARGE ACCUMULATION OF MISCELLANEOUS HOU
- Authorized use versus observed occupancy · 35729361JSection 28-301.1 / OATH code 189 · FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR AS PER BC 1008.
- Masonry or façade deterioration · 39195339PSection 28-301.1 / OATH code 202 · OBSERVED AT GROUND LEVEL DECORATIVE BROWN STONE SPALLING AND SCALING LEFT AND RIGHT OF ENTRY DOOR., REPAIR AND/OR REPLACE; MAKE RE
- Elevator device maintenance and safety devices · 39204203HSection 28-301.1 / OATH code 251 · VF... HOIST MACHINE BRAKE MAINTENANCE TAG UPDATE MISSING PROVIDE....8.6.4.6..... MAINTENANCE LOG UPDATE MISSING PROVIDE... 8.6.1.4
- Fire prevention or detection system · 39204427RSection 28-301.1 / OATH code 102 · ATOI OBSERVED IN THE GARAGE AREA A MAKE SHIFT CAR DETAILING SHOP IN WHICH THEY HAD A HOSE PULLING WATER FROM A HOSE BIB CONNECTED
- Elevator device maintenance and safety devices · 39204065ZSection 28-301.1 / OATH code 251 · CLASS 2 ITEMS: ELEVATOR PIT CONTAINS EXCESSIVE DIRT/DEBRIS ACCUMULATION AND IS NOT MAINTAINED IN CLEAN CONDITION, IN VIOLATION OF
- Authorized use versus observed occupancy · 39204597JSection 28-301.1 / OATH code 102 · AT REAR OF BUILDING,AT 3RD FLOOR, SIDING FINISH MISSING EXPOSING ROOM TO THE ELEMENTS. INTERIOR OF APARTMENT,CERAMIC TILES MISSING
- Plumbing fixture and drainage configuration · 39204425NSection 28-301.1 / OATH code 102 · ATOI OBSERVED THE WATER HEATERS ON THE 3RD AND 4TH FLOOR BEING HOUSED IN A TIGHT CLOSET NOT ALLOWING ACCESS TO THE WATER HEATERS F
- Safe building maintenance · 39203512RSection 28-301.1 / OATH code 102 · AGGRAVATED CONDITIONS OBSERVED AT TIME OF INSPECTION, CONSISTENT WITH VIOLATION #39153716X ISSUED 7/11/2025 FOR FAILURE TO MAINTAI
- Masonry or façade deterioration · 35683916NSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. OBSERVED LOOSE BRICK WORK, LARGE STEP CRACKS, CRACKED STONEWORK, SPALLING
- Roof and weather protection · 39202679YSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER. OBSERVED ROOF IN A STATE OF DISREPAIR, OPEN HOLES OBSERVED AT EXP 1 & 2. SH
- Roof and weather protection · 39204340YSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED; BUILDING HAS BEEN OBSERVED WITH DEFECTIVE GUTTER LEADER NOT BEING DI
- Unprotected openings and fall exposure · 39204461KSection 28-301.1 / OATH code 102 · IN REAR YARD, NO FALL PROTECTION OR GUARDRAILS ON OPENING WHERE LADDER IS OBSERVED. WIRES, LADDERS, AND OTHER EQUIPMENT BEING UNMA
- Safe building maintenance · 39204247JSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED 4 HIGH POWERED LED LIGHT IN STORAGE LOT ILLU
- Elevator device maintenance and safety devices · 39203580ZSection 28-301.1 / OATH code 251 · 1) INOPERATIVE IN-CAR COMMUNICATION.
- Windows, doors and openings · 39204323MSection 28-301.1 / OATH code 202 · NOTED AT THE TIME OF INSPECTION. OBSERVED STEP CRACKING AT THE FRONT STOOPS. AT RIGHT SIDE OF THE PROPERTY OBSERVED MULTIPLE WINDO
- Authorized use versus observed occupancy · 39204366MSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT INTERIOR 2ND FLOOR APARTMENT(FRONT) CEILI
- Zoning, site use or regulated sign · 39165592LSection 28-301.1 / OATH code 302 · NOTED THE CURB AT EXPOSURE #1 (RIGHT HAND CORNER) WAS ILLEGALLY REMOVED AND REPLACED WITH A 11'X15' PARKING PAD. CONTRARY TO BC 32
- Boiler device inspection and filing · 39204186PSection 28-301.1 / OATH code 354 · FEDERAL BOILER HAS A DEFECTIVE HOT WATER TEMPERATURE GAUGE+BOILER ROOM LIGHT+CEILING ABOVE OIL TANK;CORRECT VIOLATION+SUBMIT CERTI
- Masonry or façade deterioration · 39202148PSection 28-301.1 / OATH code 302 · OBSERVED AT REAR OF PREMISES A DETERIORATED MASONRY GARAGE STRUCTURE WITH LOOSE/DISPLACED BRICK MASONRY AND AN OPEN DETERIORATED S
- Elevator safety and service status · 39202456RSection 28-301.1 / OATH code 151 · VF... R T S... 97-X-17..... ELEVATOR IN BUILDING OUT OF SERVICE , UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE CREATIN
- Structural and interior building component · 39204413XSection 28-301.1 / OATH code 202 · ATOI, OBSERVED AT PREMISES IN STAIRCASES, HALLWAYS AND COMMON AREAS; VARIOUS ITEMS (GYM EQUIPMENT, LADDERS, TOOL BIN/ STORAGE, SHO
- Safe building maintenance · 39204391YSection 28-301.1 / OATH code 151 · (CEASE USE) DEFECTIVE ZONE RESTRICTOR.
- Zoning, site use or regulated sign · 39163383XSection 28-301.1 / OATH code 102 · ATOI OBSERVED A DOZEN RETAIL TYPE PLYWOOD TABLES ALONG EXP 2 AT SIDE OF SIDEWALK. POTENTIAL FOR INJURY TO PEDESTRIANS. ALSO IN REA
- Authorized use versus observed occupancy · 39204577MSection 28-301.1 / OATH code 102 · ECB VIOLATING ISSUED FOR FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER: ATOI OBSERVED IN THE INTERIOR OF THE RESIDENT NO G
- Safe building maintenance · 39203982LSection 28-301.1 / OATH code 251 · VF... MACHINE ROOM NO MEANSOF ACCESS..PROVIDE MEANS OF ACCESS, 2.7.3.3... CAR TOP DIRTY CLEAN 8.6.4.9.... HOIST WAY DOOR GIBS WORN
- Elevator device maintenance and safety devices · 39204312RSection 28-301.1 / OATH code 251 · CLASS 2: FIREFIGHTER'S SERVICE PHASE II - PHASE II DOES NOT BYPASS RESTRICTED ACCESS TO FLOOR 2, FAILING REQUIRED FIRE EMERGENCY A
- Means of egress and exit protection · 39195758JSection 28-301.1 / OATH code 189 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER BC 1018.1 (2
- Masonry or façade deterioration · 39204243MSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN A SAFE AND CODE-COMPLIANT CONDITION. ATOI OBSERVED PREMISES IS 1 STORY STORE BUILDING HAS MULTIPLE
- Safe building maintenance · 39204462MSection 28-301.1 / OATH code 102 · 1RCNY TABLE 1 (STREET). STRUCTURE BEING ILLEGAL BUILT UP TO LOT LINE, CREATING HAZARDOUS CONDITIONS JUST IN CASE OF EMERGENCY RESP
- Zoning, site use or regulated sign · 39204405XSection 28-301.1 / OATH code 232 · OBSERVED EXIT DISCHARGED SIGNS NOT WORKING WHEN TESTED FOR COMMERCIAL SPACE ON GROUND FLOOR (E.N.Y. FRUITS AND VEGETABLES) AT TIME
- Elevator device maintenance and safety devices · 39174825HSection 28-301.1 / OATH code 251 · REPLACE WORN GIBS WHERE NEEDED. ADJUST MISALINGED HOISTWAY DOOR GIBS WHERE NEEDED. RESTORE SERVICE TO CELLAR LEVEL. EXPIRED BRAKE
- Masonry or façade deterioration · 39197055MSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN. AT TIME OF INSPECTION, SPAULING AND BROKEN CONCRETE, SHIFTED, CRACKED STONE STEPS, CAUSING TRIPPING HAZARDS F
- Masonry or façade deterioration · 39204445KSection 28-301.1 / OATH code 102 · OBSERVED STAIRCASE WALL/HALLWAY WITH MULTIPLE HOLES AND CRACKS AT 4TH FLOOR OUTSIDE APT D1, REPAIR AND/REPLACE
- Windows, doors and openings · 39203952KSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION OBSERVED AT EXP. #1 CRACKED/CHIPPED WINDOWSILLS AND HOLES IN MASONRY BETWEEN 4TH FLOOR AND PARAPET LEVEL AND
- Elevator device maintenance and safety devices · 39204054NSection 28-301.1 / OATH code 251 · CLASS 2 ITEM: ACCESS TO ELEVATOR MACHINE ROOM WAS NOT PROVIDED AT TIME OF INSPECTION, PREVENTING INSPECTION AND ACCESS TO ELEVATOR
- Elevator device maintenance and safety devices · 39203937MSection 28-301.1 / OATH code 251 · CLASS 2 ITEMS: ELEVATOR CAR POSITION INDICATOR IS INOPERATIVE AND REQUIRES REPAIR APPLICABLE ASME A17.1 INDICATOR REQUIREMENTS ACC
- Elevator safety and service status · 39204274PSection 28-301.1 / OATH code 251 · MISSING IN CASE OF FIRE SIGNS (BC 3002.3). ADJUST HOISTWAY DOOR ACCESS HOLES TO A HEIGHT NO GREATER THAN 83" (2.12.6.2.5.). PROIVD
- Elevator safety and service status · 39204408LSection 28-301.1 / OATH code 151 · CLASS 1 (CU):FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER PASSENGER ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INS
- Authorized use versus observed occupancy · 39196332RSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT INTERIOR APARTMENT 3R & BASEMENT ROOM AT
- Elevator safety and service status · 39204209ZSection 28-301.1 / OATH code 151 · 1) THE ENTIRE DOOR OPERATOR IS MALFUNCTIONING. THIS CAUSING THE ELEVATOR TO HAVE DLM FAULTS. REPAIR/REPLACE THE DOOR OPERATOR AND
- Zoning, site use or regulated sign · 39204212JSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN PROPERTY LOT AT FRONT YARD ACCUMULATION IN CORNER OF DEBRIS, CINDER & CONCRETE BLOCKS, WOOD STORED ON GRASS AR
- Boiler device inspection and filing · 39163301NSection 28-301.1 / OATH code 254 · SMITH BOILER HAS CORRODED STEAM RETURN PIPING+TEMPORARY PIPE CLAMP+INCORRECT PIPING ON STEAM CONTROLS+COMBUSTION AIR LOUVERS 1/2 C
- Structural and interior building component · 39204265NSection 28-301.1 / OATH code 202 · OBSERVED HOUSEHOLD ITEMS PARTIALLY BLOCKING HALLWAY AND LANDING TO STEP.B AT GROUND FLOOR AND 2 FLOOR, REPAIR AND/OR REPLACE
- Plumbing fixture and drainage configuration · 39204424LSection 28-301.1 / OATH code 102 · ATOI OBSERVED HOT WATER HEATERS ON THE 3RD & 4TH FLOORS INSTALLED USING PVC ON THE FRESH AIR INTAKES AND ON THE THIRD FLOOR THE FR
- Elevator safety and service status · 39204586YSection 28-301.1 / OATH code 151 · FAILURE TO MAINTAIN ELEVATOR EQUIPMENT AS PER BC 3001.2 & 27-987 UPON AN INSPECTION THE ELEVATOR IS FOUND TO BE OUT OF SERVICE CRE
- Roof and weather protection · 39204379LSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED ROOF-LEVEL METAL CORNICE DETERIORATED WIT
- Elevator device maintenance and safety devices · 39194510LSection 28-301.1 / OATH code 251 · RTS CLASS 2: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REM
- Roof and weather protection · 39204108JSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER, EXCESSIVE DEBRIS AT (EXP 1,3,4), CANOPY ROOF AT REAR (EXP 3) IN STATE OF DI
- Elevator device maintenance and safety devices · 39203842JSection 28-301.1 / OATH code 251 · CLASS 2 ITEMS: PROVIDE AND MAINTAIN PROPER VENTILATION IN THE ELEVATOR CAR IN ACCORDANCE WITH ASME A17.1-2013 2.14.2.3. ELEVATOR C
- Authorized use versus observed occupancy · 35690106RSection 28-301.1 / OATH code 189 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER: LACK OF REQUIRED NUMBER MEANS OF EGRESS FOR EVERY FLOOR AS PER BC 1008.1(
- Elevator device maintenance and safety devices · 39204116JSection 28-301.1 / OATH code 251 · CLASS 2 ITEM: IN-CAR COMMUNICATION IS NOT CONNECTED TO A CONTINUOUSLY STAFFED LOCATION, AS REQUIRED BY NYC BUILDING CODE ASME A17.
- Gas equipment or fuel piping · 39204336LSection 28-301.1 / OATH code 102 · ATOI OBSERVED IN THE GAS METER ROOM MULTIPLE LEAKS ON THE HOUSE SIDE OF THE SERVICE. CON EDISON ARRIVE & SHUT DOWN & LOCKED SERVIC
- Plumbing fixture and drainage configuration · 39166024HSection 28-301.1 / OATH code 102 · NEW PVC AND COOPER PIPE INSTALLED IN BATHROOMS OF ALL 3 FLOORS. APPROX 85% COMPLETE. WWP., REPAIR AND/REPLACE
- Boiler device inspection and filing · 39204436ZSection 28-301.1 / OATH code 102 · ATOI OBSERVED IN BASEMENT OPEN ENDED GAS LINE. ORIGINALLY FEEDING BOILER AND HOT WATER HEATER. PER B102 CLASS 1 28-301.1 FAILURE T
- Electrical installation and permit · 39203697MSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HOLES AT CEILING EXPOSING WOODEN JOISTS, AND BROKEN ELECTRICAL LIG
- Elevator device maintenance and safety devices · 39203918RSection 28-301.1 / OATH code 251 · 1) THERE IS WATER IN THE PIT (8.11.2.1.3). 2) THERE IS A LIGHT OUT IN THE CAB (8.11.2.1.1). 3) THE BRAKE TAG IS EXPIRED (8.11.1.6)
← Previous Page 6 of 18 Next →