- Scaffold platform and fall protection · 39559097XSection UNSPECIFIED / OATH code 2P5 · OSUPPORTED SCAFFOLD INSTALLED AT EXP#4 APPROX. 2 FEET FROM ADJOINING PROPERTY WINDOWS(436 CARROLL STR) -SUPPORTED SCAFFOLD NET ON
- Means of egress and exit protection · 39559069ZSection UNSPECIFIED / OATH code 2P7 · OBSERVED SUPPORT OF EXCAVATION WORK MORE THAN 10 FT DEEP WITH HEAVY MACHINERY WITHOUT 1:1 SLOPE RAMP OR LADDERS FOR A SAFE MEANS O
- Specific cited provision requiring manual cross-check · 39559111NSection UNSPECIFIED / OATH code 2P7 · AT TIME OF INSPECTION, OBSERVED CLOSED PROPOSED 10-STORY NB SITE IN FOUNDATION PHASE WITH 9,915 SF PROPOSED. NO WATCHPERSON WAS PR
- Street / sidewalk occupancy and dot authorization · 39559041RSection UNSPECIFIED / OATH code 1P7 · BC3303.5.3 AT THE TIME OF MY INSPECTION OF A 10 STORY NEW BUILDING AT 5 FLOOR DECKING LEVEL, I OBSERVED AT EXPOSURE #1, 2 CONCRETE
- Traffic barriers and worksite separation · 39559118XSection UNSPECIFIED / OATH code 2P7 · BC3307.2.1 AT TIME OF INSPECTION OBSERVED WORK AND STORAGE ZONE/ JERSEY BARRIERS EXTENDED BEYOND CONSTRUCTION SITE OCCUPYING ADJ P
- Street / sidewalk occupancy and dot authorization · 39559098HSection UNSPECIFIED / OATH code 2P7 · DURING MY INSPECTION OF A CLOSED 4-STORY NB. I OBSERVED NO ACTIVE CONSTRUCTION WORK; ONE DEBRIS CONTAINER IN PLACE AT ROADWAY EXPO
- Scaffold platform and fall protection · 39559101JSection UNSPECIFIED / OATH code 2P7 · BC3314.1 AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD INSTALLED ON TOP OF SIDEWALK SHED. SCAFFOLD PLANKS LOOSE NOT TIED DOWN
- Specific cited provision requiring manual cross-check · 39559031NSection UNSPECIFIED / OATH code 2P7 · INADEQUATE STORAGE ZONE NO PROTECTION AT EXCAVATORCOMPLY WITH CODE
- Street / sidewalk occupancy and dot authorization · 39559039HSection UNSPECIFIED / OATH code 2P7 · AT TIME OF INSPECTION, I OBSERVED A CONSTRUCTION DEBRIS CONTAINER IN THE PUBLIC ROADWAY @EXP#4. UPON REVIEW OF DOT DATA BASE, NO D
- Specific cited provision requiring manual cross-check · 35730982KSection UNSPECIFIED / OATH code 1Q5 · FAILURE TO SECURE PUBLIC SAFETY AND/OR MAKE THE BUILDING'S STRUCTURE AND APPURTENANCES CONFORM TO THE PROVISIONS OF ADMIN. CODE AF
- Sidewalk shed and public protection · 39559040PSection UNSPECIFIED / OATH code 2P7 · AT TIME OF INSPECTION, I OBSERVED WITHIN THE PROPERTY LINE OF THE SITE AT EXP#1 NO SIDEWALK SHED BETWEEN THE BUILDING AND THE CONS
- Means of egress and exit protection · 39203811RSection UNSPECIFIED / OATH code 1P7 · MISC. CHPT 33 VIOLATIONS. NOT COMPLYING WITH FILED TPP FOR EGRESS AND HEALTH REQUIREMENTS SECTIONS. OBSERVED AT UNMARKED APT DOOR
- Scaffold platform and fall protection · 39559083PSection UNSPECIFIED / OATH code 2N5 · AT TIME OF INSPECTION I OBSERVED SUPPORTED SCAFFOLD ERECTED AT EXP 3 WITH DEBRIS AND MATERIALS AT STAIR WAY OBSTRUCTING EGRESS THE
- Traffic barriers and worksite separation · 39559015NSection UNSPECIFIED / OATH code 2P7 · BC3307.4.7-WORK/STORAGE ZONE- I OBSERVED WORK/STORAGE ZONE AT EXP 1 STREET- OBSERVED MATERIAL STORED APPROXIMATELY 4- 5 1/2 FT HIG
- Specific cited provision requiring manual cross-check · 39559127HSection UNSPECIFIED / OATH code 2P7 · BC3303.3 WATCHPERSON 12 STORY NEW BUILDING, BUILDING APPROXIMATELY 11880 SQUARE FEET. SITE CLOSED AND THERE WERE NO CONSTRUCTION A
- Sidewalk shed and public protection · 39559057LSection UNSPECIFIED / OATH code 2L7 · AT TIME OF INSPECTION, OBSERVED 5-STORY BUILDING WITH SIDEWALK SHED AT EXPOSURE 1. NO ACTIVE SIDEWALK SHED PERMIT WAS FOUND ON REC
- Permit validity timeline · 39559130ZSection UNSPECIFIED / OATH code 2P8 · AT THE TIME OF INSPECTION, I OBSERVED A SIDEWALK SHED ERECTED AT A 6-STORY EXITING'S BUILDING. RESEARCH OF DOB NOW AND BIS RECORDS
- Masonry or façade deterioration · 39203449NSection UNSPECIFIED / OATH code 1Q3 · FAILURE TO MAINTAIN - PARKING STRUCTURE FOR 35726735L. OBSERVED BEAMS AND WALLS THROUGH-OUT PARKING STRUCTURE WITH SEVERE CRACKS,
- Roof and weather protection · 39559089XSection UNSPECIFIED / OATH code 1P3 · NOTE: AT TIME OF INSPECTION I OBSERVED ADJACENT BUILDING AT EXPOSURES# 2 AND 3 MISSING THE REQUIRED WEATHERPROOFING AS PER 3309.9,
- Structural and interior building component · 39559151HSection UNSPECIFIED / OATH code 1P7 · RESPONDING TO THE INCIDENT IN WHICH A WORKER WAS STRUCK BY A CHANNEL BEAM, INVESTIGATION REVEALED THAT TWO WORKERS WERE PUSHING AN
- Fire prevention or detection system · 39559138NSection UNSPECIFIED / OATH code 2N6 · AT THE TIME OF INSPECTION ON AN ACTIVE JOB SITE , I OBSERVED THRU OUT BUILDING AND ON CONSTRUCTION FENCE THAT FIRE EXTINGUISHERS T
- Demolition, structural removal or excavation · 39559126XSection UNSPECIFIED / OATH code 2P7 · PERFORMED AFTER HOUR VARIANCE SWEEP ON CLOSED JOBSITE FOR PROPOSED DEMOLITION OF A 2-STORY HOUSE. UPON INSPECTION, OBSERVED TREE O
- Street / sidewalk occupancy and dot authorization · 39559114ZSection UNSPECIFIED / OATH code 1P7 · NOTE: AT THE TIME OF INSPECTION, AN INADEQUATE ROADWAY WORK/STORAGE ZONE WAS OBSERVED ADJACENT TO THE SIDEWALK WITH CONSTRUCTION M
- Scaffold platform and fall protection · 39559135HSection UNSPECIFIED / OATH code 2P7 · OBSERVED 7 STORY OCCUPIED BLDG. AT TIME OF INSPECTION I OBSERVED SUPPORTED SCAFFOLD ERECTED AT FRONT AND REAR OF PROPERTY. SS DEBR
- Scaffold platform and fall protection · 39559093ZSection UNSPECIFIED / OATH code 1P7 · BC 3303.11.2 AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING TOP OFF, I OBSERVED WORKERS INSTALLING SUPPORTED PIPE SCAFFOLD
- Street / sidewalk occupancy and dot authorization · 39559115KSection UNSPECIFIED / OATH code 2P7 · NOTE: AT TIME OF INSPECTION, I OBSERVED THAT THE SIDEWALK IS CLOSED, UPON REVIEWING DOT RECORDS IT WAS NOTED THAT NO PERMIT WAS IS
- Authorized use versus observed occupancy · 35726149ZSection UNSPECIFIED / OATH code 1Q3 · FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION.NOTE:AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTING 1 L
- Permit validity timeline · 39559140MSection UNSPECIFIED / OATH code 2P7 · AT THE TIME OF INSPECTION, I OBSERVED SIDEWALK SHEDS AT EXPOSURES #1 AND #4 WITH VALID PERMITS. PERMIT #B00489724-I1-SH EXPIRES 10
- Specific cited provision requiring manual cross-check · 39559128JSection UNSPECIFIED / OATH code 2P7 · BC3303.3 WATCHPERSON 10 STORY NEW BUILDING, BUILDING APPROXIMATELY 9618 SQUARE FEET. SITE CLOSED AND THERE WERE NO CONSTRUCTION AC
- Means of egress and exit protection · 39559173ZSection UNSPECIFIED / OATH code 2P7 · AT THE TIME OF INSPECTION OF A 3-STORY NEW BUILDING IN EXCAVATION/FOUNDATION EXCEEDING 6 FEET IN DEPTH WITHOUT A SAFE MEANS OF ING
- Scaffold platform and fall protection · 39559177XSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE WITH ERECTED PIPE SCAFFOLD @ EXP. 2 WITHOUT PROPERLY BEING SECURE: MISSING TIES
- Scaffold platform and fall protection · 39559182KSection UNSPECIFIED / OATH code 2P7 · BC3314.1 AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD INSTALLED AT EXP#1 NOT MAINTAINED AS PER CODE. SCAFFOLD MISSING MID-RAI
- Specific cited provision requiring manual cross-check · 39204139MSection UNSPECIFIED / OATH code 1N5 · FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. OBSERVED EXCESSIVE STORAGE HAVING COMBUSTIBLE MATERIALS ( WOOD
- Sidewalk shed and public protection · 39559160JSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF INSPECTION SIX-STORY NEW BUILDING I OBSERVED AT EXPOSURE #1, ADJACENT TO SIDEWALK SHED MATERIALS STORED ON STREET A
- Demolition, structural removal or excavation · 39559171PSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF INSPECTION OF A 3-STORY NEW BUILDING IN THE EXCAVATION/FOUNDATION PHASE, I OBSERVED AN EXCAVATOR OPERATING AT EXPOS
- Permit validity timeline · 39558987NSection UNSPECIFIED / OATH code 2P8 · OBSERVED SIDE WALK SHED OF 4 STORY BUILDING .NO UNSAFE CONDITIONS AT TIME OF INSPECTION PERMIT IS EXPIRED (08/25/2026) EXPIRED PER
- Sidewalk shed and public protection · 39559163PSection UNSPECIFIED / OATH code 2L7 · @BUILDING NO VALID BUILDING CONSTRUCTION PERMIT OBSERVE DAMAGED&UNMAINTAINED SIDEWALK SHED IN PLACE&I VERIFIED PER DEPARTMENTS REC
- Unprotected openings and fall exposure · 39559172RSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF INSPECTION OF A PROPOSED 3 STORY NEW BUILDING, I OBSERVED GUARDRAIL SYSTEM AT EXP3&4 REMOVED TO MANEUVER EXCAVATOR.
- Specific cited provision requiring manual cross-check · 39145320JSection UNSPECIFIED / OATH code 1P7 · AT TIME OF INSPECTION ON AN ACTIVE JOBSITE I OBSERVED A PLATFORM BUILT AT BACK YARD MADE OF PLANKS AND PLYWOOD WITH A STEP LADDER
- Demolition, structural removal or excavation · 39559183MSection UNSPECIFIED / OATH code 2P7 · AT TIME OF INSPECTION OF 25 STORY ALT JOB OBSERVED DEMOLITION OPERATIONS THROUGHOUT BUILDING WITHOUT WATER, FILTERED VACUUMS, DUST
- Specific cited provision requiring manual cross-check · 39559175MSection UNSPECIFIED / OATH code 1P3 · AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE WITH ON GOING STRUCTURAL OPERATIONS. (BC 3309.1)THE SITE ERECTED STEEL@ THE REAR
- Structural and interior building component · 39204219MSection UNSPECIFIED / OATH code 1P7 · AT TIME OF INSPECTION WHERE WORKER FELL AT STAIRS DUE TO STAIR STEEL TREAD WAS REPLACED IMPROPERLY WITH PARTIAL WOODEN TREAD AND R
- Sidewalk shed and public protection · 39559162NSection UNSPECIFIED / OATH code 1P3 · AT THE TIME OF INSPECTION SIX-STORY NEW BUILDING I OBSERVED AT EXPOSURE #4 NO OVERHEAD PROTECTION FOR ADJACENT PROPERTY'S BALCONY.
- Scaffold platform and fall protection · 39204231PSection UNSPECIFIED / OATH code 2P7 · ATOI, FAILURE TO PROVIDE AND MAINTAIN REQUIRED SAFETY DEBRIS NETTING AT SCAFFOLD, NOT ONLY IN LOADING AREA BUT IN MULTIPLE SECTION
- Roof and weather protection · 39559228RSection UNSPECIFIED / OATH code 2P7 · AT THE TIME OF INSPECTION OF A 9-STORY NEW BUILDING AT ROOF LEVEL, I OBSERVED AN ELECTRIC BICYCLE/SCOOTER STORED WITHIN THE ACTIVE
- Zoning, site use or regulated sign · 39559212MSection UNSPECIFIED / OATH code 1P7 · AT TIME OF INSPECTION OF A PROPOSED 18-STORY NB IN ACTIVE EARTHWORK PHASE WITH AN APPROVED DOB SITE SAFETY PLAN, UPON REQUEST NO D
- Specific cited provision requiring manual cross-check · 39559216JSection UNSPECIFIED / OATH code 1P7 · AT TIME OF INSPECTION OF PROPOSED 18-STORY NBS AT 94-09 AND 94-11 148 STREET, UNDER APPLICATIONS Q01338988-I1 AND Q01295343-I1, TW
- Specific cited provision requiring manual cross-check · 39556394ZSection UNSPECIFIED / OATH code 2P7 · SITE SAFETY PLAN--BC3301.13.1-AT THE TIME OF MY INSPECTION OF ACTIVE JOB SITE UPON REQUEST PERSON IN CHARGE/WORKERS -FOR SITE SAFE
- Zoning, site use or regulated sign · 39559224JSection UNSPECIFIED / OATH code 2P7 · AT TIME OF INSPECTION OF ACTIVE 18-STORY NB IN EARTHWORK PHASE, CS RAVI KUNJBEHARI, PERMIT Q01338988-I1-SE, WAS ALSO DESIGNATED CS
- Zoning, site use or regulated sign · 39540706MSection UNSPECIFIED / OATH code 1P7 · 28-104.7.10 AT THE TIME OF MY INSPECTION OF A 4 STORY NEW BUILDING, I OBSERVED ACTIVE JOBSITE, UPON REQUEST FOR SITE SAFETY PLAN T
- Permit validity timeline · 39195913KSection UNSPECIFIED / OATH code 2P8 · FN PERMIT#X00350083, HAS EXPIRED ON 01/29/26., RENEW PERMIT; RENEW PERMIT
- Structural and interior building component · 39540710PSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF MY INSPECTION OF A 4 STORY NEW BUILDING 2ND FLOOR LEVEL, I OBSERVED STAIRS FROM THE 1ST FLOOR TO THE 2ND FLOOR WITH
- Permit validity timeline · 39559194HSection UNSPECIFIED / OATH code 2P8 · AT THE TIME OF INSPECTION, I OBSERVED A SIDEWALK SHED ERECTED AT A 6-STORY OCCUPIED BUILDING. RESEARCH OF DOB NOW AND BIS RECORDS
- Permit validity timeline · 39559246KSection UNSPECIFIED / OATH code 2P8 · AT THE TIME OF MY INSPECTION I OBSERVED SIDEWALK SHED INSTALLED AT EXP#1 AND EXP#4 UNDER APPLICATION # B01400655-UPON CHECKING DOB
- Permit validity timeline · 39559191MSection UNSPECIFIED / OATH code 2P8 · AT TIME OF INSPECTION, OBSERVED SIDEWALK SHED AT A 5-STORY BUILDING. SIDEWALK SHED PERMIT X00916393-I1-SH EXPIRED ON 08/26/2026 AN
- Structural and interior building component · 39554014ZSection UNSPECIFIED / OATH code 1P7 · DURING ACTIVE CONCRETE POURING OPERATIONS AT THE 3RD FLOOR SLAB OF A 6-STORY PROPOSED NEW BUILDING, NO VERTICAL DEBRIS NETTING SYS
- Sidewalk shed and public protection · 39559242NSection UNSPECIFIED / OATH code 2P8 · AT THE TIME OF INSPECTION OF A 6-STORY RESIDENTIAL BUILDING, I OBSERVE SIDEWALK SHED IN PLACE COVERING PERIMETER OF THE BUILDING F
- Scaffold platform and fall protection · 39559219PSection UNSPECIFIED / OATH code 2P7 · BC 3314.1 & 3314.4.4.1 SAFE WORKING ORDER. OBSERVED SYSTEMS SCAFFOLD AT ELEVATOR SHAFT W/ MISSING TOE BOARDS AS REQUIRED IN MANUFA
- Scaffold platform and fall protection · 39559230XSection UNSPECIFIED / OATH code 2P7 · AT THE TIME OF INSPECTION OF A 9-STORY NB, I OBSERVED WORKERS USING ERECTED PIPE SCAFFOLDING FOR STUCCO OPERATION, UPON REQUEST FO
- Sidewalk shed and public protection · 39559197NSection UNSPECIFIED / OATH code 1P3 · AT TIME OF INSPECTION OF 3 STORY DEMOLITION SITE I OBSERVED AT REAR OF DEMOLITION HAD NO OVERHEAD PROTECTION OVER ADJACENT PROPERT
- Roof and weather protection · 39559227PSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF INSPECTION OF A 9-STORY NEW BUILDING AT ROOF LEVEL, I OBSERVED THAT NO CONSTRUCTION FIRE SAFETY MANAGER WAS AVAILAB
- Zoning, site use or regulated sign · 39556276HSection UNSPECIFIED / OATH code 2P7 · ATOI OF A PROPOSED 7-STORY NB, THE JOB SITE WAS NON-ACTIVE WITH NO PERSONNEL PRESENT. THE SITE EXCEEDED 9,000 SQ FT AND REQUIRED A
- Sidewalk shed and public protection · 39540707YSection UNSPECIFIED / OATH code 1P3 · AT THE TIME OF MY INSPECTION OF A 4 STORY NEW BUILDING 2ND FLOOR LEVEL, I OBSERVED THAT THE OVERHEAD PROTECTION FOR ADJACENT PROPE
- Zoning, site use or regulated sign · 39559310XSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE FAILED TO DESIGNATE CS/COMPETENT PERSON AS REQUIRED(BC 3301.13.3)( 3301.13.12) U
- Street / sidewalk occupancy and dot authorization · 39559265XSection UNSPECIFIED / OATH code 1P7 · 3307.2.1. AT THE TIME OF INSPECTION, I OBSERVED A BOOM TRUCK ON STREET AT EXP #4 OCCUPYING APPROXIMATED 20 FEET OF THE ROADWAY. UP
- Zoning, site use or regulated sign · 39559270KSection UNSPECIFIED / OATH code 2P7 · BC 3301.9- CONSTRUCTION SIGNS - AT THE TIME OF INSPECTION MISSING FLOOR NUMBER SIGNS ( BC3301.9.5 ) OBSERVED NO SMOKING SIGNS ON T
- Scaffold platform and fall protection · 39559285NSection UNSPECIFIED / OATH code 2P7 · 3314.1 AT INSPECTION, WORKERS WERE PERFORMING HOUSEKEEPING. PIPE SCAFFOLD AT EXP# 1, 2, 3 & 4 WAS UNSAFE, WITH MISSING GUARDRAILS,
- Sidewalk shed and public protection · 39559302XSection UNSPECIFIED / OATH code 1P3 · AT THE TIME OF INSPECTION I OBSERVED, STEEL BEAM FRAMING STRUCTURE APPROXIMATELY 30 FEET HIGH AND AT EXPOSURE #4 NO OVERHEAD PROTE
- Sidewalk shed and public protection · 39540709HSection UNSPECIFIED / OATH code 2P7 · BC 3315.1.6 AT THE TIME OF MY INSPECTION OF A 4 STORY NEW BUILDING 2ND FLOOR LEVEL, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE
- Tenant protection plan / occupied-site safeguards · 39202834PSection UNSPECIFIED / OATH code 1N7 · FAILURE TO PROVIDE PROTECTION FOR TENANTS DURING DEMOLITION OR CONSTRUCTION ACTIVITY IN AN OCCUPIED BUILDING. OBSERVED WORK INADEQ
- Fire prevention or detection system · 39559269NSection UNSPECIFIED / OATH code 2N6 · AT THE TIME OF INSPECTION I OBSERVED INADEQUATE FIRE EXTINGUISHERS/ DIAL WAS SHOWN EMPTY ON ONE FIRE EXTINGUISHER. MUTIPLE FIRE EX
- Permit posting at the inspection location · 39202832LSection UNSPECIFIED / OATH code 2L4 · FAILURE TO POST OR DISTRIBUTE NOTICE OF TPP MEETING REQUIREMENTS. OBSERVED NO TTP POSTINGS ON FIRST FLOOR. CONSTRUCTION IS BEING C
- Street / sidewalk occupancy and dot authorization · 39559262KSection UNSPECIFIED / OATH code 1P7 · 3307.2,1 AT THE TIME OF INSPECTION, I OBSERVED CONCRETE WASHOUT BOX AND BOBCAT IN FRONT OF BUILDING AT 1719 VOORHIES AVENUE ON STR
- Permit validity timeline · 39559266HSection UNSPECIFIED / OATH code 2P8 · AT THE TIME OF INSPECTION ON A NON ACTIVE JOB SITE , I OBSERVED SIDEWALK SHED AT EXPOSURE 1 UPON MY REVIEW THRU DOB NOW SWS PERMIT
- Fire prevention or detection system · 39559307PSection UNSPECIFIED / OATH code 2N6 · OBSERVATION: FIRE EXTINGUISHERS W/O DATE OR TAGS THROUGHOUT SITE. VIO FOR FAILURE TO MAINTAIN FIRE EXTINGUISHERS.MAINTAIN FIRE EXT
- Scaffold platform and fall protection · 39559249XSection UNSPECIFIED / OATH code 2P7 · PSWO STOP ALL WORK ON SUPPORTED SCAFFOLD. I SAW A WORKER ON SUPP. SCAFFOLD AT EXP#4 WITH NO GUARDRAIL SYSTEM OR FALL PROTECTION IN
- Scaffold platform and fall protection · 39559245ZSection UNSPECIFIED / OATH code 1P7 · BC3314.1 AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD INSTALLED AT EXP#3 NOT MAINTAIN AS PER CODE. SCAFFOLD, PLATFORMS NOT FU
- Means of egress and exit protection · 39559251PSection UNSPECIFIED / OATH code 2P7 · UPON INSPECTION I OBSERVED INADEQUATE AND UNSAFE BARRIERS/ STREET STORAGE IN STREET AT EXPOS 1. BARRIERS DO NOT MEET THE REQUIREME
- Permit validity timeline · 39556296PSection UNSPECIFIED / OATH code 2P8 · AT THE TIME OF INSPECTION, I OBSERVED A SIDEWALK SHED ERECTED AROUND A 7-STORY OCCUPIED BUILDING. REVIEW OF DOB NOW AND BIS RECORD
- Scaffold platform and fall protection · 35728205NSection UNSPECIFIED / OATH code 1P7 · FAILURE TO INSTITUTE REQUIRED SAFETY MEASURES. AT TIME OF INSPECTION, PER ANTHONY PALMIOTTO SUB CONTRACTOR WORKER VICTOR LOPEZ FEL