Cases associated with NYC DOB UNSPECIFIED
461 distinct descriptions associated with this law label in the October 2026 enforcement extract. These are source allegations with educational draft analyses, not verified outcomes.
- Scaffold platform and fall protection · 39204387LSection UNSPECIFIED / OATH code 2P7 · ATOI OBSERVED WORKER NOT PROPERLY SECURED BY LIFELINE WHILE WORKING ON THE SUSPENDED SCAFFOLD APPROX 6 STORIES HIGH POSING AN UNSA
- Fire prevention or detection system · 39559222XSection UNSPECIFIED / OATH code 2N6 · OBSERVATION: FIRE EXTINGUISHERS NOT MAINTAINTED W/O TAGS THROUGH OUT SITE. VIO FOR FAILURE TO MAINTENANCE FIRE EXTINGUISHERS.MAINT
- Scaffold platform and fall protection · 39559305LSection UNSPECIFIED / OATH code 2P7 · OBSERVATION: AT 2ND FLOOR SUPPORT SCAFFOLD INADEQUATELY CONSTRUCTED. NO BRACING,BASEPLATE,MUDSILLS). PSWO FOR SCAFFOLD INADEQUATEL
- Scaffold platform and fall protection · 35728210HSection UNSPECIFIED / OATH code 1P7 · FAILURE TO ERECT SUPPORTED SCAFFOLD IN ACCORDANCE WITH CODE. AT TIME OF INSPECTION THE SCAFFOLD WAS OBSERVED WITHOUT REQUIRED GUAR
- Specific cited provision requiring manual cross-check · 39559187JSection UNSPECIFIED / OATH code 1N4 · AT TIME OF INSPECTION IN RESPONSE TO AN INCIDENT THAT OCCURRED WHERE AYODOCK WITH A FENCE SYSTEM INSTALLED TIPPED OVER AND STRUCK
- Sidewalk shed and public protection · 39559261ZSection UNSPECIFIED / OATH code 1P7 · 3307.4.7. AT THE TIME OF INSPECTION, I OBSERVED A BOOM AND DELIVERY TRUCK ON THE STREET ADJACENT TO THE SIDEWALK SHED AT EXPOSURE
- Street / sidewalk occupancy and dot authorization · 39559332RSection UNSPECIFIED / OATH code 2P7 · BC3303.4.2 A DEBRIS CONTAINER WAS OBSERVED ON EXP 1 ROADWAY IT HAS BEEN NOT COVERED AFTER WORKING HOURS, I KNOCKED ON THE DOOR SEV
- Structural and interior building component · 39556779JSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF MY INSPECTION OF A 2 STORY NEW BUILDING, I OBSERVED STEEL FRAMING IN OPERATION WORKERS WELDING "I" BEAM, FABRICATIO
- Specific cited provision requiring manual cross-check · 39556739PSection UNSPECIFIED / OATH code 1P7 · BC3316.1 INSPECTION OF AN 8 STORY BUILDING THE HOIST AT EXPOSURE #3 THE LOGS & SPEAKING TO THE SAFETY PERSONAL, IT WAS REVEALED TH
- Scaffold platform and fall protection · 39559381NSection UNSPECIFIED / OATH code 2P7 · ATOI, I OBSERVED A CLOSED SITE. DEBRIS NETTING ON SUPPORTED SCAFFOLD AT LOCATIONS#2 AND#4 IS NOT FULLY UPRIGHT LEAVING SECTIONS OF
- Elevator safety and service status · 39559352YSection UNSPECIFIED / OATH code 1P7 · BC3303.12 ELEVATOR DURING CONSTRUCTION.@11STORY NB SITE UP TO 10TH FL CONCRETE WORKING DECK OBSERVE TEMP ELEVATOR UP TO 5TH FL FAI
- Specific cited provision requiring manual cross-check · 39559356LSection UNSPECIFIED / OATH code 1N4 · STEET BARRIERS.@11STORY NB SITE IN STRUCTURE PHASE OBSERVE STREET BARRIERS(TIGER BARRIERS, ROCK ROADSAFETY) COVER PERIMETER OF SIT
- Unprotected openings and fall exposure · 39559319MSection UNSPECIFIED / OATH code 1P7 · RESPONDING TO AN INCIDENT WHERE A WORKER FELL APPROX. 11 FT. TO 11TH FL. LEVEL. INSPECTION REVEALED THAT WORKER WAS ATTEMPTING TO
- Construction fencing or site enclosure · 39549796XSection UNSPECIFIED / OATH code 2P7 · JOBSITE FENCE NOT MAINTAINED AS PER 3307.7. FENCE @EXPO1 DISLODGING ONTO PEDESTRIAN WALKWAY,AT RISK OF FALLING ON PUBLIC.PUT PUBLI
- Scaffold platform and fall protection · 39559325ZSection UNSPECIFIED / OATH code 2P7 · 3314.4.5 AT INSPECTION OF A 2-STORY BUILDING, ACTIVE WORK WAS OBSERVED. PIPE SCAFFOLDS AT EXP. 1 AND 4 HAD IMPROPERLY STORED BRICK
- Structural and interior building component · 39559354HSection UNSPECIFIED / OATH code 2P7 · BC3308.6 HORIZONTAL SAFETY NETTING SYSTEM.@11STORY NEW BUILDING SITE UP TO 10TH FLOOR CONCRETE WORKING DECK OBSERVE SECTION OF HOR
- Windows, doors and openings · 39559277NSection UNSPECIFIED / OATH code 1P7 · BC 3309.1 & BC3301.1.1 OBSERVED: ACTIVE SITE WORKING ON 2ND AND 3RD LEVEL CS PRESENT UPON INSPECTION NOTED ADJACENT PROPERTY WINDO
- Roof and weather protection · 39556740MSection UNSPECIFIED / OATH code 1P7 · BC3303.8 STANDPIPE READINESS: DURING INSPECTION OF A 8 STORY BUILDING AT THE ROOF/BULKHEAD LEVEL I OBSERVED THAT THE STANDPIPE WAS
- Scaffold platform and fall protection · 39532095MSection UNSPECIFIED / OATH code 1P7 · BC 3314.4 FAILURE TO MAINTAIN SCAFFOLD AS PER CODE. OBSERVED SUPPORTED SCAFFOLD INSTALLED AT EXP#1 NOT AS PER CODE, SCAFFOLD HAS U
- Structural and interior building component · 39559316RSection UNSPECIFIED / OATH code 1P7 · AT THE OF THE INSPECTION OF A 3-STORY BUILDING 3RD FLOOR DECKING LEVEL, I OBSERVED WORKERS FRAMING THE SECOND AND THIRD FLOOR DECK
- Specific cited provision requiring manual cross-check · 39549621YSection UNSPECIFIED / OATH code 2P7 · AT TIME OF INSPECTION IN A PROPOSED 4 STORY NEW BUILDING OBSERVED: SITE CLOSED NO ACCESS, NO CONSTRUCTION ACTIVITIES. PEDESTRIAN W
- Scaffold platform and fall protection · 39559331PSection UNSPECIFIED / OATH code 1P7 · I OBSERVED PIPE SCAFFOLD INSTALLED AT EXPOS 2 & 4 IN A UNSAFE MANNER. INADEQUATE AND UNSAFE FOOTINGS. NO STACKING PINS INSTALLED.
- Authorized use versus observed occupancy · 39204173XSection UNSPECIFIED / OATH code 1Q3 · AT TIME OF INSPECTION OBSERVED SPALLED /CRACKED CONCRETE AND REINFORCEMENT EXPOSED AT CELLAR AND 1ST FLOOR LEVEL ALSO #35717622K I
- Scaffold platform and fall protection · 39549622XSection UNSPECIFIED / OATH code 2P7 · AT TIME OF INSPECTION OBSERVED: SUPPORTED SCAFFOLD IN PLACE AT EXPOSURE# 1 OF SITE LOOSE NETTING DEBRIS AND TEAR APART NOT MAINTAI
- Authorized use versus observed occupancy · 39204134NSection UNSPECIFIED / OATH code 1Q3 · AT TIME OF INSPECTION OBSERVED SPALLED /CRACKED CONCRETE AT CELLAR AND 1ST FLOOR LEVEL ALSO VIOLATION #35717621Z ISSUED ON 10-18-2
- Scaffold platform and fall protection · 39559336YSection UNSPECIFIED / OATH code 2P3 · UPON INSPECTION OF AN ACTIVE 2 STORY ALT I OBSERVED PIPE SCAFFOLD INSTALLED IN A UNSAFE MANNER ( POTENTIAL COLLAPSE, EQUIPMENT AND
- Construction fencing or site enclosure · 39556778HSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF MY INSPECTION OF A 2 STORY NEW BUILDING, I OBSERVED STEEL FRAMING IN OPERATION, WORKERS WELDING "I" BEAM AND INSTAL
- Specific cited provision requiring manual cross-check · 39549797HSection UNSPECIFIED / OATH code 2N8 · OBSERVED CLOSED 3STORY NB. PEDESTRIAN WALKWAYS BEING USED @EXPOS1&4 NOT UP TO CODE. PEDESTRIAN WALKWAY IS NOT MINIMUM OF 5FT AS RE
- Traffic barriers and worksite separation · 39559377KSection UNSPECIFIED / OATH code 2P7 · PSWO. STOP ALL USE OF STORAGE ZONE LOCATED AT EXP#1. ATOI, I OBSERVED A CLOSED SITE OF A PROPOSED 8 STORY STRUCTURE. STORAGE ZONE
- Specific cited provision requiring manual cross-check · 39549807MSection UNSPECIFIED / OATH code 2P7 · PROPOSED 11 STORY NB WITH A BUILDING FOOTPRINT (SQ. FT.)12583. OBSERVED NO CONSTRUCTION ACTIVITY TAKIN PLACE AT THE TIME OF INSPEC
- Authorized use versus observed occupancy · 39549645ZSection UNSPECIFIED / OATH code 2P7 · BC 3307.2.1 AT TIME OF INSPECTION OBSERVED: CONSTRUCTION FENCE IN PLACE USING SIDEWALK COMPLETELY. UPON REVIEWING DEPARTMENT RECOR
- Scaffold platform and fall protection · 39559324RSection UNSPECIFIED / OATH code 2P7 · 3314.1 AT INSPECTION OF A 2-STORY BUILDING, PIPE SCAFFOLDS AT EXP. 1 AND 4 HAD LOOSE PLANKING, MATERIALS/TOOLS, AND NO GUARDRAILS.
- Structural and interior building component · 39559283JSection UNSPECIFIED / OATH code 1P7 · 3308.5 & 3308.5.2OBSERVED : ACTIVE SITE CS PRESENT UPON INSPECTION NOTED DEBRIS NETTING ON SECOND FLOOR INADECUATE AND CONTRARY TO
- Scaffold platform and fall protection · 39559361XSection UNSPECIFIED / OATH code 1P7 · BC 3314.1: AT INSPECTION OF A 2-STORY BUILDING, WORKERS WERE PERFORMING STUCCO OPERATIONS. PIPE SCAFFOLDS AT EXP#. 2, 3 & 4 WERE U
- Fire prevention or detection system · 39559343MSection UNSPECIFIED / OATH code 2N6 · OBSERVATION: FIRE EXTINGUISHERS NOT MAINTAINED, LAST DATE 4/24/26 THROUGHOUT SITE.. VIO FOR FAILURE TO MAINTAIN FIRE EXTINGUISHERS
- Scaffold platform and fall protection · 39559341ZSection UNSPECIFIED / OATH code 2P7 · PSWO STOP ALL USE OF SUPPORTED SCAFFOLD LOC AT EXP#4 I OBSERVED SUPPORTED SCAFFOLD AT EXPOSURE #4 INSTALLED ON TOP OF SIDEWALK SHE
- Authorized use versus observed occupancy · 39146318PSection UNSPECIFIED / OATH code 1N4 · NOTED THAT A CARPENTER WORKING ON 7TH FL AND BASEMENT PARTIALLY AMPUTATED FINGER ON TABLE SAW. SAW WAS NOT ERECTED TO FULL HIEGHT
- Specific cited provision requiring manual cross-check · 39549823MSection UNSPECIFIED / OATH code 2P7 · ATOI OF A 8-STORY NEW BUILDING, BUILDING APPX. 27,653 SQ FT. SITE CLOSED AND THERE WAS NO CONSTRUCTION ACTIVITY. UPON SHOUTING AT
- Authorized use versus observed occupancy · 39556665LSection UNSPECIFIED / OATH code 2P7 · OBSERVED 1FL STAIRCASE TO CELLAR BY EXP #1-2 COVERED WITH A MAKESHIFT PLATFORM, MADE BY PLYWOOD, A FEW 2X4 LUMBERS AND SHATTERED P
- Unprotected openings and fall exposure · 39559344YSection UNSPECIFIED / OATH code 2P7 · I OBSERVED MISSING TEMP LIGHTS ON REAR PERIMETER OF 2FLOOR NO WORKING TEMP LIGHTS ON 3 FLOOR THRU 4TH FLOOR. IN VIOLATION OF BC 33
- Street / sidewalk occupancy and dot authorization · 39559188LSection UNSPECIFIED / OATH code 2P7 · PLASTIC BARRICADES AT EXPOSURE 1 ARE NOT MAINTAINED AS REQUIRED BY CODE MISSING SAND OR WATER AND INTERLOCKING DEVICES TO PREVENT
- Specific cited provision requiring manual cross-check · 39559394MSection UNSPECIFIED / OATH code 2P7 · 3307.2 STREETS, INCLUDING BICYCLE LANES & SIDEWALK...ATOI OBSERVED A JLB AERIAL BOOM LIFT IN FRONT OF A 5 STORY RESIDENTIAL BUILDI
- Permit validity timeline · 39559403PSection UNSPECIFIED / OATH code 2P8 · AT THE TIME OF MY INSPECTION, I OBSERVED A SIDEWALK SHED IN PLACE ON EXPOSURE #1 WITH PERMIT # B01197992. UPON REVIEW OF DEPARTMEN
- Scaffold platform and fall protection · 39559342KSection UNSPECIFIED / OATH code 2P7 · PSWO STOP ALL USE OF SUPPORTED SCAFFOLD AT EXPSOURE#4 . SITE COULD NOT PROVIDE LOADS IMPOSED LETER FOR INSTALL SCAFFOLD ON SIDEWAL
- Permit posting at the inspection location · 39196665PSection UNSPECIFIED / OATH code 2L5 · AT TIME OF INSPECTION OBSERVED TPP UNDER ACTIVE JOB PERMITS TPP-M01070661-I1-01 TPP-M01070717-I1-01 FAILURE TO POST AND DISTRIBUTE
- Scaffold platform and fall protection · 39536826PSection UNSPECIFIED / OATH code 1P7 · BC 3314.4.4.12 DURING INSPECTION I OBSERVED THAT THE SUPPORTED SCAFFOLD IN PLACE AT EXPOSURE #3 THE POWERLINES ATTACHED TO THE STR
- Specific cited provision requiring manual cross-check · 39556667PSection UNSPECIFIED / OATH code 2N8 · OBSERVED INADEQUATE STORAGE ZONE ON SIDEWALK WITH PILES OF MATERIALS WITHOUT ANY PROTECTION AROUND THEM, PLYWOOD AND SOIL ON PATHW
- Roof and weather protection · 39549513RSection UNSPECIFIED / OATH code 2P3 · AT TIME OF INSPECTION OBSERVED 2 STORY BUILDING ROOF LEVEL UNDER CONSTRUCTION IN PROGRESS WITHOUT PROTECTION FOR ADJACENT PROPERTY
- Authorized use versus observed occupancy · 39556711NSection UNSPECIFIED / OATH code 1P3 · UPON INSPECTION OF AN ACTIVE 4 STORY ALT CONSTRUCTION SITE I OBSERVED EXTENSION WORK IN PROGRESS AT EXPOSURE 4 WITH NO OVERHEAD PR
- Sidewalk shed and public protection · 39556929XSection UNSPECIFIED / OATH code 2P8 · AT THE TIME OF MY INSPECTION OF A 5 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE # 1 AND 2, UPON REVIEW OF THE DE
- Structural and interior building component · 39196574JSection UNSPECIFIED / OATH code 1P7 · FAILURE TO COMPLY WITH TPP, ATOI I OBSERVED UNDER HEALTH REQUIREMENTS TPP STATES THAT THERE WILL BE PLASTIC PARTITION,WALK-OFF STI
- Permit validity timeline · 35731078RSection UNSPECIFIED / OATH code 2P8 · EXPIRED SIDEWALK SHED PERMIT. AS NOTED: AT THE TIME OF INSPECTION SIDEWALK SHED PERMIT WAS EXPIRED. PERMIT EXPIRED ON 04/01/2026.
- Permit validity timeline · 35730335YSection UNSPECIFIED / OATH code 2P8 · EXPIRED SIDEWALK SHED PERMIT. NOTED AT THE TIME OF INSPECTION I OBSERVED THAT PERMIT FOR SIDEWALK SHED HAD EXPIRED. I CHECKED THE
- Masonry or façade deterioration · 39550838NSection UNSPECIFIED / OATH code 2P7 · UPON INSPECTION I OBSERVED POTENTIAL TRIPPING HAZARDS ON SIDEWALK AT EXPOS 1 & 2. LARGE CRACKS AND UNEVEN PEDESTRIAN WALKWAY FROM
- Specific cited provision requiring manual cross-check · 39548240XSection UNSPECIFIED / OATH code 2P7 · 15 STORIES NB INACTIVE JOBSITE, WITH A BUILDING FOOTPRINT(41,386 ) SQ.FT. , WALK JOBSITE PERIMETERS, KNOCK & CALLED OUT, I OBSERVE
- Permit validity timeline · 35730334MSection UNSPECIFIED / OATH code 2P8 · EXPIRED SIDEWALK SHED PERMIT. NOTED AT THE TIME OF INSPECTION I OBSERVED THAT PERMIT FOR SIDEWALK SHED HAD EXPIRED. I CHECKED THE
- Authorized use versus observed occupancy · 35730983MSection UNSPECIFIED / OATH code 1Q3 · FAILURE TO MAINTAIN PARKING STRUCTURE IN A SAFE CONDITION. AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTING OF 01
- Zoning, site use or regulated sign · 35730987JSection UNSPECIFIED / OATH code 1Q5 · FAILURE TO SECURE PUBLIC SAFETY AND/OR MAKE THE BUILDING'S STRUCTURE AND APPURTENANCES CONFORM TO PROVISIONS OF ADMIN CODE. AT TIM
- Permit validity timeline · 35730186JSection UNSPECIFIED / OATH code 2P8 · EXPIRED SIDEWALK SHED PERMIT. AT THE TIME OF INSPECTION OBSERVED EXPIRED PERMIT FOR SIDEWALK SHED, I CHECKED THE DOB AND BIS WEBSI
- Authorized use versus observed occupancy · 35730989NSection UNSPECIFIED / OATH code 2Q8 · FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITIONS. AS NOTED: ATTIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTI
- Permit validity timeline · 39557093JSection UNSPECIFIED / OATH code 2P8 · AT TIME OF INSPECTION OF 6 STORY RESIDENTIAL BUILDING OBSERVED SIDEWALK SHED IN ÝLACE WITH PERMIT # M01332555 EXPIRED 1-26-26 CAUS
- Authorized use versus observed occupancy · 35730972RSection UNSPECIFIED / OATH code 2Q8 · FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTIN
- Authorized use versus observed occupancy · 35730973ZSection UNSPECIFIED / OATH code 1Q3 · FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED AT TIME OF INSPECTION ON ACTIVE OCCUPIED PARKING STRUCTURE CONSI
- Sidewalk shed and public protection · 39558594MSection UNSPECIFIED / OATH code 2P7 · AT TIME OF INSPECTION, OBSERVED SIDEWALK SHED IN PLACE WITH VERTICAL MEMBERS THROUGHOUT THE SHED NOT MAINTAINED PLUMB WITHIN THE L
- Permit validity timeline · 35730184XSection UNSPECIFIED / OATH code 2P8 · EXPIRED SIDEWALK SHED PERMIT. AT THE TIME OF INSPECTION OBSERVED EXPIRED PERMIT FOR SIDEWALK SHED POSTED AT THE FENCE, I CHECKED D
- Permit validity timeline · 35730185HSection UNSPECIFIED / OATH code 2P8 · EXPIRED SIDEWALK SHED PERMIT. AT THE TIME OF INSPECTION OBSERVED EXPIRED FOR SIDEWALK SHED #340210373-01-EQ-SH ON 12-03-2015. I CH
- Fire prevention or detection system · 39200106HSection UNSPECIFIED / OATH code 2N6 · OBSERVED PERMIT HOLDER X01131310-I1-GC-CX FAILED TO PROVIDED FIRE EXTINGUISHER THROUGHOUT ACTIVE JOB SITE UNDER CONSTRUCTION OPERA
- Specific cited provision requiring manual cross-check · 39199605RSection UNSPECIFIED / OATH code 1P3 · AT TIME OF INSPECTION OBSERVED DAMAGED ADJACENT BUILDING (1455 55 STREET) DUE TO CONSTRUCTION ACTIVITY. AS PER PRECONSTRUCTION SUR
- Permit posting at the inspection location · 35730327YSection UNSPECIFIED / OATH code 2P8 · EXPIRED SIDEWALK SHED PERMIT. NOTED: AT TIME OF INSPECTION I OBSERVED THAT PERMIT FOR SIDEWALK SHED HAD EXPIRED. I CHECKED ON THE
- Permit validity timeline · 35730872JSection UNSPECIFIED / OATH code 2P8 · EXPIRED SIDEWALK SHED PERMIT. NOTED AT THE TIME OF INSPECTION I OBSERVED THAT PERMIT FOR SIDEWALK SHED HAD EXPIRED. I CHECKED THE
- Permit posting at the inspection location · 35730874NSection UNSPECIFIED / OATH code 2P8 · EXPIRED SIDEWALK SHED PERMIT. NOTED AT THE TIME OF INSPECTION I OBSERVED THAT PERMIT FOR SIDEWALK SHED HAD EXPIRED. I CHECKED ON T
- Specific cited provision requiring manual cross-check · 35730329HSection UNSPECIFIED / OATH code 1P7 · MISCELLANEOUS CHAPTER 33 VIOLATIONS. NOTED AT THE TIME OF INSPECTION IOBSERVED LOOSE AND FLAPPING NETTING ON ALL EXPOSURES 1, 2, 3
- Scaffold platform and fall protection · 39532842RSection UNSPECIFIED / OATH code 1P7 · BC 3314.1 UNSAFE SUPPORTED SCAFFOLD. OBSERVE 5 FRAME HIGH SUPPORTED SCAFFOLD AT EXP#3-4 PLATFORM NOT FULL DECKED NOR TIED DOWN&INA
- Sidewalk shed and public protection · 39557225MSection UNSPECIFIED / OATH code 2P7 · OBSERVED SIDEWALK SHED NOT MAINTAIN IN CODE COMPLYING MANNER. INADEQUATE FOUNDATION ON COUPLE OF VERTICAL POST ON TREES. ALSO OBSE
- Specific cited provision requiring manual cross-check · 35717600JSection UNSPECIFIED / OATH code 264 · UNLAWFUL ACTS, FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. ASNOTED: A REVIEW OF OUR RECORDS AND PROPERTY FILINGS REVEALED
- Specific cited provision requiring manual cross-check · 39532845MSection UNSPECIFIED / OATH code 1P7 · INADEQUATE SITE SAFETY ORIENTATION BC3301.11. DURING FATALITY FOLLOW UP INSPECTION, PERSONNEL PROVIDED NONE CODE COMPLIANT ORIENTA
- Means of egress and exit protection · 39559365NSection UNSPECIFIED / OATH code 2P7 · BC3304.7 ACCESS.IN RESPONSE TO INCIDENT OF WORKER INJURED&TRANSPORTED TO HOSPITAL OBSERVE APPROX. 5'DEPTH EXCAVATION FOR NEW SEWER
- Specific cited provision requiring manual cross-check · 39559129LSection UNSPECIFIED / OATH code 2P7 · BC3303.3 WATCHPERSON 10 STORY NEW BUILDING, BUILDING APPROXIMATELY 8640 SQUARE FEET. SITE CLOSED AND THERE WERE NO CONSTRUCTION AC
- Scaffold platform and fall protection · 39180121KSection UNSPECIFIED / OATH code 2P7 · AT TIME OF INSPECTION OBSERVED AT 2ND FLOOR AND ATTIC LEVEL UNPROTECTED EDGES WHERE NO FALL PROTECTION (GUARDRAILS) AND NO TOE BOA
- Structural and interior building component · 39559046XSection UNSPECIFIED / OATH code 1P7 · BC3301.1.2 AT THE TIME OF MY INSPECTION OF A 10 STORY NEW BUILDING AT 5 FLOOR DECKING LEVEL, UPON REQUEST FOR FIRE SAFETY MANAGER