Cases associated with NYC DOB UNSPECIFIED
461 distinct descriptions associated with this law label in the October 2026 enforcement extract. These are source allegations with educational draft analyses, not verified outcomes.
- Permit validity timeline · 39556831HSection UNSPECIFIED / OATH code 2P8 · AT TIME OF INSPECTION UPON REVIEWING DOB NOW AND BIS SYSTEM REVEALS TEMPORARY CONSTRUCTION EQUIPMENT SIDEWALK SHED PERMIT X0137102
- Scaffold platform and fall protection · 39557104XSection UNSPECIFIED / OATH code 2P7 · 3314.1 OBSERVED SUPPORTED SCAFFOLD ERECTED AND IN USE WITHOUT A COMPLETE GUARDRAIL SYSTEM OR TOE BOARDS. SEVERAL SCAFFOLD LEGS WER
- Permit validity timeline · 35716981HSection UNSPECIFIED / OATH code 2P8 · TEMP. CONSTRUCTION EQUIP/INSTALLATION ON SITE EXPIRED PERMIT(SHED). ASNOTED: AT THE TIME OF INSPECTION I OBSERVED SHED PERMIT WAS
- Sidewalk shed and public protection · 39559168YSection UNSPECIFIED / OATH code 2P8 · AT THE TIME OF MY REINSPECTION OF A FOUR-STORY BUILDING, AN ACTIVE JOB SITE WAS OBSERVED. A SIDEWALK SHED WAS IN PLACE AT EXPOSURE
- Masonry or façade deterioration · 39204358MSection UNSPECIFIED / OATH code 1Q3 · FAILURE TO MAINTAIN- PARKING STRUCTURE .OBSERVED GARAGE IN A STATE OF DISREPAIR ,CRACKS,SPALLING AND MISSING PIECES OF CONCRETE SL
- Permit validity timeline · 39549581ZSection UNSPECIFIED / OATH code 2P8 · AT TIME OF INSPECTION OF A 5 STORIES BUILDING I OBSERVED SIDEWALK SHED INSTALLED ON EXPOSURE # 1 AND 2 UPON REVIEW THE DEPARTMENT
- Scaffold platform and fall protection · 39557138YSection UNSPECIFIED / OATH code 2P7 · PSWO/STOP ALL USE OF SUPPORTED SCAFFOLD EXP#4. SCAFFOLD INSTALLED AT EXP#4 OF STRUCTURE IS LESS THAN 10FT FROM ENERGIZED POWERLINE
- Specific cited provision requiring manual cross-check · 39546710MSection UNSPECIFIED / OATH code 2P7 · 3303.3 AT TIME OF MY INSPECTION OF A 13-STORY NB, BUILDING APPROXIMATELY 10161 SQUARE FEET.SITE CLOSED AND THERE WERE NO CONSTRUCT
- Scaffold platform and fall protection · 39172621RSection UNSPECIFIED / OATH code 2P7 · ATOI OBSERVED SUPPORTED PIPE SCAFFOLD IN PLACE WITH INADEQUATE MEANS OF INGRESS/ EGRESS, MISSING DEBRIS NETTING TO SECURE WORK ARE
- Authorized use versus observed occupancy · 35730092ZSection UNSPECIFIED / OATH code 2Q8 · FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED: AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTI
- Windows, doors and openings · 39543337JSection UNSPECIFIED / OATH code 2P7 · AT TIME OF INSPECTION, EXPOSURE 2 LACKED COMPLIANT OVERHEAD PROTECTION, NETTING, WINDOW PROTECTION, LIGHTING, AND SAFETY SIGNAGE.
- Roof and weather protection · 39557599RSection UNSPECIFIED / OATH code 2P4 · AT THE TIME OF INSPECTION OF A 2-STORY BUILDING, INADEQUATE ROOF PROTECTION WAS OBSERVED AT EXP# 2 OVER THE ADJACENT PROPERTY. PLY
- Zoning, site use or regulated sign · 35730991MSection UNSPECIFIED / OATH code 1Q5 · FAILURE TO SECURE PUBLIC SAFETY AND/OR MAKE THE BUILDING'S STRUCTURE AND APPURTENANCES CONFORM TO PROVISIONS OF THE ADMIN CODE AFT
- Permit validity timeline · 39546454MSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF MY INSPECTION OF A 2 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1 AND 2 WITH A VALID PERMIT EXP
- Authorized use versus observed occupancy · 35730981ZSection UNSPECIFIED / OATH code 1Q3 · FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITIONS. AS NOTED: ATTIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTI
- Structural and interior building component · 39556892LSection UNSPECIFIED / OATH code 2P7 · 3303.7.7.1 3303.11AT INSPECTION OF THE 5-STORY BUILDING, WORKERS WERE OBSERVED ON THE 5TH FLOOR. ACCESS TO THE WORK AREA WAS BY LA
- Street / sidewalk occupancy and dot authorization · 39556924RSection UNSPECIFIED / OATH code 2P7 · BC 3307.2.1 AT TIME OF INSPECTION OBSERVED: CONCRETE TRUCKS, BARRIERS, CONCRETE WASH OUT BOX AND POT PARTY IN PLACE USING ROADWAY,
- Authorized use versus observed occupancy · 35730990KSection UNSPECIFIED / OATH code 2Q8 · FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED: AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTI
- Specific cited provision requiring manual cross-check · 39546307MSection UNSPECIFIED / OATH code 1P7 · AT TIME OF INSPECTION, OBSERVED TWO LIFELINES ATTACHED TO THE SAME ANCHOR POINT. CONTRARY TO BC 3314.6.3, EACH LIFELINE SHALL BE S
- Authorized use versus observed occupancy · 35730133XSection UNSPECIFIED / OATH code 2Q8 · FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED AT TIME OF INSPECTION ON AN ACTIVE OCCUPIED PARKING STRUCTURE CO
- Structural and interior building component · 39529288LSection UNSPECIFIED / OATH code 2P7 · SITE SAFETY PLAN PHASES INADEQUATE/CONTRARY AS PER BC 3301.13.1: AT INSPECTION, IT WAS OBSERVED DIESEL TANK FOR CRANE AERIAL FUEL
- Scaffold platform and fall protection · 39552078ZSection UNSPECIFIED / OATH code 2P3 · AT THE TIME OF MY INSPECTION I OBSERVED SUPPORTED SCAFFOLD/WORK ABOVE/NEXT TO ADJ PROPERTIES SETBACKS AT EXP#2/4-NO PROTECTION PRO
- Sidewalk shed and public protection · 39556881XSection UNSPECIFIED / OATH code 1P7 · BC3307.2.1 AT INSPECTION OF THE 5-STORY BUILDING, THE SIDEWALK SHED OBSTRUCTED THE PEDESTRIAN WALKWAY, REDUCING THE REQUIRED 5-FT
- Street / sidewalk occupancy and dot authorization · 39556879RSection UNSPECIFIED / OATH code 2P7 · 3307.4.7AT INSPECTION OF THE 5-STORY NEW BUILDING, UNSAFE STORAGE OF MATERIALS, APPROXIMATELY 6 FT HIGH, WAS OBSERVED ON THE ROADW
- Authorized use versus observed occupancy · 35730985XSection UNSPECIFIED / OATH code 1Q3 · FAILURE TO MAINTAIN PARKING STRUCTURE IN A SAFE CONDITION. AS NOTED ATTIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTI
- Demolition, structural removal or excavation · 39557342LSection UNSPECIFIED / OATH code 1P7 · BC 3310.5.3 AT THE TIME OF MY INSPECTION OF A 17 STORY NEW BUILDING AT FOUNDATION/EXCAVATION PHASE, I OBSERVED UNDERPINNING IN PRO
- Scaffold platform and fall protection · 39550259ZSection UNSPECIFIED / OATH code 2P7 · AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE @ EXP. 4 FAILURE TO MAINTAIN ERECTED SUPPORTED SCAFFOLD 3314.1 : NOT FULLY PLANK
- Sidewalk shed and public protection · 39556890HSection UNSPECIFIED / OATH code 1P3 · AT INSPECTION OF THE 5-STORY BUILDING, WORKERS PERFORMING FORMWORK AND REBAR WORK ON THE 5TH FLOOR LACKED REQUIRED OVERHEAD PROTEC
- Roof and weather protection · 39556889KSection UNSPECIFIED / OATH code 1P4 · AT INSPECTION OF THE 5-STORY NEW BUILDING, WORKERS WERE OBSERVED PERFORMING FORMWORK & REBAR ON THE 5TH FLOOR WITHOUT REQUIRED ROO
- Authorized use versus observed occupancy · 35730132YSection UNSPECIFIED / OATH code 1Q3 · FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED AT TIME OF INSPECTION ON AN ACTIVE OCCUPIED PARKING STRUCTURE CO
- Authorized use versus observed occupancy · 35730986HSection UNSPECIFIED / OATH code 1Q3 · FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED: AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTI
- Scaffold platform and fall protection · 39552077RSection UNSPECIFIED / OATH code 2P7 · BC 3314.1-SUPPORTED SCAFFOLD BUILD IN UNSAFE MANNER-I OBSERVED SUPPORTED SCAFFOLD INSTALLED AT EXP# 1/3 IN UNSAFE MANNER-EXP#1 MIS
- Scaffold platform and fall protection · 35718342KSection UNSPECIFIED / OATH code 1P6 · FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION. DAMAGED PLANKING/DECKING WERE SEVERLY ROTTED/DA
- Unprotected openings and fall exposure · 39543824RSection UNSPECIFIED / OATH code 2P7 · 3304.4.4 AT THE TIME OF MY INSPECTION OF A TWO-STORY BUILDING UNDERGOING DEMOLITION, EXCAVATION, CONCRETE POURING, AND STRIPPING O
- Demolition, structural removal or excavation · 39543825ZSection UNSPECIFIED / OATH code 2P7 · BC 3301.2 AT THE TIME OF MY INSPECTION OF A TWO-STORY BUILDING UNDERGOING DEMOLITION, EXCAVATION, CASTING, AND STRIPPING OPERATION
- Specific cited provision requiring manual cross-check · 39551719PSection UNSPECIFIED / OATH code 2P7 · NO WATCHPERSON ON SITE AT THE TIME OF INSPECTION OF A 4 STORY NEW BUILDING UNDER CONSTRUCTION AT FOUNDATION PHASE APPROXIATEMATELY
- Specific cited provision requiring manual cross-check · 39551859RSection UNSPECIFIED / OATH code 2N8 · OBSERVED SIDEWALK NARROWED BY FENCE, REDUCING PEDESTRIAN SPACE AND CREATING A HAZARD TO THE PUBLIC. NO DOT PERMIT POSTED OR FOUND
- Permit validity timeline · 39552108KSection UNSPECIFIED / OATH code 2P8 · SIDEWALK SHED PERMIT X00294312-I1-SH EXPIRED ON 04/05/2024. SHED IN USE WITHOUT A VALID PERMIT, CREATING A HAZARD TO THE PUBLIC. B
- Specific cited provision requiring manual cross-check · 35726188LSection UNSPECIFIED / OATH code 1Q5 · FAILURE TO SECURE PUBLIC SAFETY AND/OR MAKE THE BUILDING'S STRUCTURE AND APPURTENANCES CONFORM TO THE PROVISIONS OF THE ADMIN CODE
- Specific cited provision requiring manual cross-check · 39549103YSection UNSPECIFIED / OATH code 2P6 · AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE MISSING PLANKING @ LEVEL 1 &2 & @ EXP. 4 THIS PROVIDE UNSAFE CONDITIONS FOR ALL
- Permit validity timeline · 39557292MSection UNSPECIFIED / OATH code 2P8 · EXPIRED SIDEWALK SHED PERMIT. NOTE AT THE TIME OF INSPECTION OBSERVED SIDEWALK SHED PERMIT EXPIRED ON 01/13/2025 AND NO PERMIT POS
- Specific cited provision requiring manual cross-check · 39536878RSection UNSPECIFIED / OATH code 2P7 · BC 3307.2.1 FAILURE TO COMPLY WITH DOT REGULATIONS AS PER 34 RCNY 2- 05. AT THE TIME OF MY INSPECTION I OBSERVED BARRIERS PLACED A
- Specific cited provision requiring manual cross-check · 39197001RSection UNSPECIFIED / OATH code 2N5 · FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. OBSERVED EXCESSIVE CONSTRUCTION DEBRIS IN COMMERCIAL SPACE WOR
- Street / sidewalk occupancy and dot authorization · 39546642JSection UNSPECIFIED / OATH code 2P7 · BC 3307.2.1. AT THE TIME OF INSPECTION, OBSERVED CONSTRUCTION MATERIALS PLACED ON THE PUBLIC STREET WITHOUT A VALID DOT PERMIT, TH
- Sidewalk shed and public protection · 35728168NSection UNSPECIFIED / OATH code 1P7 · PROTECTION OF ADJOINING EQUIPMENT AND SPACES. JOBSITE DID NOT PROVIDE OVERHEAD PROTECTION AY EXPOSURE 4 SIDE OF SITE. ADJOINING PR
- Specific cited provision requiring manual cross-check · 35721664KSection UNSPECIFIED / OATH code 1P3 · FAILURE TO PROVIDE PROTECTION IF ADJOINING PROPERTY DURING CONSTRUCTION OR DEMOLOTION AS REQUIRED. AT TIME OF INSPECTION OBSERVED
- Sidewalk shed and public protection · 39549409RSection UNSPECIFIED / OATH code 2P7 · 3309 OBS NO ADJACENT PROPERTY OR PEDESTRIAN PROTECTION @EXPO2&3. WORK ON SETBACK ABOVE ADJACENT PROPERTY NOT COMPLETED. CONTROL AC
- Scaffold platform and fall protection · 39191727ZSection UNSPECIFIED / OATH code 1P7 · OBSERVED THE ERECTED SCAFFOLDING WITH LADDER AT LEFT SIDE EXTERIOR IS RIGHT NEXT TO THE OVERHEAD UTILITY POWER LINE AND NO PROTECT
- Fire prevention or detection system · 39191723LSection UNSPECIFIED / OATH code 2N6 · OBSERVED THERE IS NO FIRE EXTINGUISHER ON SITE AND WORKERS WORKING. STOP ALL WORK & MAKES SITE SAFE., COMPLY WITH FIRE CODE; CONTA
- Specific cited provision requiring manual cross-check · 39549375HSection UNSPECIFIED / OATH code 2P7 · PROPOSED 8 STORY BUILDING. ACTIVE CONCRETE OPERATIONS OBSERVED PORTABLE FUEL FIRE HEATERS AT 2FL. WHEN REQUESTED FOR FDNY PERMIT &
- Authorized use versus observed occupancy · 35726709HSection UNSPECIFIED / OATH code 1Q3 · FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED: AT TIME OF INSPECTION ON AN OCCUPIED PARKING GARAGE CONSISTING
- Specific cited provision requiring manual cross-check · 39549742KSection UNSPECIFIED / OATH code 2P7 · NEW 2 STORY BUILDING .OBSERBED AT TIME OF INSPECTION FAILURE TO MAINTAIN PUBLIC AREAS FREE OF SNOW AS PER CODE 3303.4.1.1AND BC330
- Scaffold platform and fall protection · 39555025ZSection UNSPECIFIED / OATH code 1P7 · THE SUPPORTED SCAFFOLD IS NOT CONSTRUCTED ACCORDING TO CODE. 3301.2 STOP ALL WORK ON THE SUPPORTED SCAFFOLD.
- Permit validity timeline · 39545834JSection UNSPECIFIED / OATH code 2P8 · AT TIME OF INSPECTION OBSERVED SIDEWALK SHED INSTALLED AT EXP#1. UPON REVIEW IN DEPARTMENT RECORDS INDICATED PERMIT B01072452-I1-S
- Demolition, structural removal or excavation · 39535256HSection UNSPECIFIED / OATH code 2P7 · 3301.5 UNSAFE CONDITIONS- OBSERVED ACTIVE JOBSITE WITH NEW WOOD FLOOR FRAMES INSTALLED WITH WOODEN JOIST THROUGHOUT. NO STRAPS PRO
- Zoning, site use or regulated sign · 39119824YSection UNSPECIFIED / OATH code 1N1 · A CASE REVIEW ON 7/24/24 REVEALED EVIDENCE THAT LICENSED PLUMBER ANTONIO SIGNORE ALLOWED THIRD PARTY USE OF HIS MASTER PLUMBERS LI
- Windows, doors and openings · 39535255XSection UNSPECIFIED / OATH code 2P7 · 3301.1.1 RESPONSIBILITY FOR SAFETY- OBSERVED NO PROTECTION PROVIDED FOR ADJACENT PROPERTIES AT EXPOSURE 2 & 4 REAR YARD EXPOSURE 3
- Fire prevention or detection system · 39535259NSection UNSPECIFIED / OATH code 2P7 · OBSERVED ACTIVE JOBSITE W/ MULTIPLE UNSAFE/VIOLATING CONDITIONS CONSISTING OF JOBSITE W/OUT FIRE EXTINGUISHERS, WORK NOT CONFORMIN
- Fire prevention or detection system · 39535254YSection UNSPECIFIED / OATH code 2P7 · 3301.1.2 FIRE CODE- OBSERVED ACTIVE JOBSITE W/OUT ANY FIRE EXTINGUISHERS ONSITE. JOBSITE CONSIST OF WOODEN JOIST & MEMBERS, COMBUS
- Unprotected openings and fall exposure · 39149128HSection UNSPECIFIED / OATH code 1P7 · NOTED: WORKER AT 2ND STORY INSTALLING WINDOWS WITHOUT FALL PROTECTION, PLATFORM NOT FULLY PLANKED, MISSING GUARDRAILS, EXCHANGING
- Sidewalk shed and public protection · 39539606RSection UNSPECIFIED / OATH code 1P3 · NO OVERHEAD PROTECTION.@2STORY FULL DEMO SITE WHERE INCIDENT OCCURRED OF BUILDING COLLAPSE ONTO SIDEWALK&STREET OBSERVE SITES EXP#
- Specific cited provision requiring manual cross-check · 39555542RSection UNSPECIFIED / OATH code 1P7 · BC3301.13.5 AT THE TIME OF MY INSPECTION OF A 5 STORY NEW BUILDING, I OBSERVED 5 WORKERS AT JOBSITE, UPON REVIEW OF THE CONSTRUCTI
- Scaffold platform and fall protection · 39555541PSection UNSPECIFIED / OATH code 1P7 · AT THE TIME OF MY INSPECTION OF A 5 STORY NEW BUILDING, I OBSERVED AT EXPOSURE #2 SUPPORTED PIPE SCAFFOLD THAT WAS NOT MAINTAIN IT
- Sidewalk shed and public protection · 39540259JSection UNSPECIFIED / OATH code 2L7 · AT THE TIME OF MY INSPECTION OF A 3 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1, UPON REVIEW OF THE DEPARTMEN
- Specific cited provision requiring manual cross-check · 39549954MSection UNSPECIFIED / OATH code 2P7 · BC3307.2.1 DOT PERMIT: DURING INSPECTION OF AN ACTIVE SITE WITH AN EXCAVATOR ONSITE AND A TRUCK BLOCKING THE SIDEWALK, DOT RECORDS
- Specific cited provision requiring manual cross-check · 35730075RSection UNSPECIFIED / OATH code 1Q5 · FAILURE TO SECURE PUBLIC SAFETY AND/OR MAKE THE BUILDING'S STRUCTURE AND APPURTENANCES CONFORM TO THE PROVISIONS OF THE ADMIN. COD
- Scaffold platform and fall protection · 39191743ZSection UNSPECIFIED / OATH code 1P7 · MISCELLANEOUS CHAPTER 33 VIOLATIONS. ATOI, OBSERVED ONGOING CONSTRUCTION WORK ON ACTIVE PERMIT # B0192827-I1-GC. NOTED UNSAFE STOR
- Permit validity timeline · 39541559XSection UNSPECIFIED / OATH code 2P8 · RESPONDING TO A COMPLAINT. OBSERVED A SHED INSTALLED AROUND THE BUILDING WITH LIGHTS ON UNDERNEATH IT. UPON CHECKING DEPARTMENT RE
- Permit validity timeline · 39201461RSection UNSPECIFIED / OATH code 2P8 · TEMPORARY CONSTRUCTION EQUIPMENT OR INSTALLATION ON SITE. EXPIRED PERMIT ON 02/04/2021 PERMIT(SHED). NOTED EXPO 1 SIDEWALK SHED AP
- Sidewalk shed and public protection · 39541556KSection UNSPECIFIED / OATH code 2L7 · OBSERVED 3 STORY BUILDING WITH SIDEWALK SHED EXP 1 WITH LIGHTING NOT MAINTAINED PER BC3307.6.4.8, REVIEWED OF BIS AND DOBNOW RECOR
- Authorized use versus observed occupancy · 39126026PSection UNSPECIFIED / OATH code 1P7 · OBSERVED STRUCTURAL WORK IN PROGRESS BETWEEN FLOORS W/ TEMPORARY MAKE-SHIFT SHORING ON OCCUPIED BUILDING TO SECURE/ SUPPORT FLOORS
- Specific cited provision requiring manual cross-check · 39544137JSection UNSPECIFIED / OATH code 2P7 · BC 3301.9.1-FENCE INFORMATION PANEL-AT THE TIME OF MY INSPECTION OBSERVED CONSTRUCTION JOB SITE WIT FENCE AT EXP #1 APPROX.70 FEET
- Sidewalk shed and public protection · 39541609PSection UNSPECIFIED / OATH code 2P7 · BC 3309.2 LICENSE TO ENTER ADJOINING PROPERTY. AT THE TIME OF MY INSPECTION , I OBSERVED OVERHEAD PROTECTION ERECTED INTO ADJACENT
- Scaffold platform and fall protection · 39550327LSection UNSPECIFIED / OATH code 2P7 · 3314.1 AT TIME OF INSPECTION OBSERVED AN INADEQUATE SUPPORTED SCAFFOLD AT EXP 3, UNSECURED BLUE TARP, MISSING, & LOOSE PLANKS, THI
- Authorized use versus observed occupancy · 35726730MSection UNSPECIFIED / OATH code 1Q3 · FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION.NOTE:AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTING OF
- Fire prevention or detection system · 39201835MSection UNSPECIFIED / OATH code 2N6 · OBSERVED ACTIVE SITE WITH WORKERS WORKING & NO VISIBLE FIRE EXTINGUISHER ON SITE., COMPLY WITH FIRE CODE; CONTACT DOBSWO@BUILDINGS
- Authorized use versus observed occupancy · 35726729PSection UNSPECIFIED / OATH code 2Q8 · FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION.NOTE:AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTING OF
- Sidewalk shed and public protection · 39558346NSection UNSPECIFIED / OATH code 1P3 · AT TIME OF INSPECTION OF AN ACTIVE DEMOLITION SITE, OBSERVED NO OVERHEAD PROTECTION AT EXPOSURE 2 TO PROTECT THE ADJOINING PROPERT
- Zoning, site use or regulated sign · 39558343HSection UNSPECIFIED / OATH code 1P7 · AT TIME OF INSPECTION, REVIEW OF THE CONSTRUCTION-SUPERINTENDENT LOG DETERMINED THAT AN ALTERNATE ACTED IN PLACE OF THE PRIMARY FO
- Specific cited provision requiring manual cross-check · 39558354NSection UNSPECIFIED / OATH code 2P7 · AT TIME OF INSPECTION, OBSERVED THE WORK/STORAGE ZONE ADJACENT TO THE SIDEWALK WAS NOT SECURED AND REMAINED ACCESSIBLE TO THE PUBL
← Previous Page 4 of 6 Next →