Cases associated with NYC DOB 28-301.1
1,428 distinct descriptions associated with this law label in the October 2026 enforcement extract. These are source allegations with educational draft analyses, not verified outcomes.
- Elevator safety and service status · 39175028JSection 28-301.1 / OATH code 151 · VF... R T S... ELEVATOR IN BUILDING OUT OF SEVICE UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE . REPAIR AND RESTORE TO
- Masonry or façade deterioration · 39182792KSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER FOR SUMMONS 39156110P. OBSERVED AT REAR YARD (EXP 3) RETAINING WALL IS IN A
- Safe building maintenance · 39161428LSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION OBSERVED EXCESSIVE DEBRIS AT EXPOSURE 4 OF PROPERTY WHICH IS ACCESSIBLE TO THE PUBLIC AND PRESENTS A SAFTY C
- Boiler device inspection and filing · 39182667LSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BOILER SYSTEM DUE TO A DELAYED IGNITION DEFECT, RESULTING IN A MINOR EXPLOSION WITHIN THE UNIT. THIS CONDITION
- Boiler device inspection and filing · 39182192RSection 28-301.1 / OATH code 254 · FOUND A HB SMITH STEAM BOILER WITH NO MANUFACTURERS LABEL/ CHIMNEY BASE HAS TO BE RESEALED/ CORRECT ALL VIOLATING CONDITIONS/ SUBM
- Elevator safety and service status · 39182078NSection 28-301.1 / OATH code 151 · UPON INSPECTION FOUND THAT THE BUILDING ONLY ELEVATOR HAS BEEN OUT OF SERVICE FOR PERIOD OF SEVERAL MONTHS THE BUILDING CONSISTS O
- Masonry or façade deterioration · 39182833HSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER FOR SUMMONS 39156057P. OBSERVED AT REAR YARD (EXP 3) RETAINING WALL IS IN A
- Boiler device inspection and filing · 39182745HSection 28-301.1 / OATH code 154 · FOUND RBI FB500 BOILER CEASE USE DUET TO HAZARDOUS CONDITION :EXPLOSION. DO NOT OPERATE BOILERS UNTIL ALL HAZARDOUS CONDITIONS ARE
- Structural and interior building component · 39182222ZSection 28-301.1 / OATH code 154 · AT TIME OF INSPECTION I FOUND A HIGH ODOR OF OIL FUMES ON THE FIRST FLOOR OF THE BUILDING. THROUGH FURTHER INVESTIGATION I FOUND H
- Elevator device maintenance and safety devices · 39182499LSection 28-301.1 / OATH code 251 · CLASS 2: IN-CAR LIGHT GUARD MISSING, INSTALL. ALARM BELL INOPERATIVE, REPAIR. MAINTENANCE LOG OUTDATED, PROVIDE UPDATED RECORDS. T
- Safe building maintenance · 39174331HSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: 1. INTERIOR HALLS AT 1ST & 2ND FLRS OBSERVED ACCUMULATED WITH MISC.
- Windows, doors and openings · 39190977RSection 28-301.1 / OATH code 102 · FTM: AT THE TIME OF INSPECTION, OBSERVED AT REAR YARD, DETACHED GARAGE, IN SEVERELY DETERIORATED CONDITION WITH PORTIONS OF ROOF A
- Boiler device inspection and filing · 39174326NSection 28-301.1 / OATH code 139 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3; 27-345. NOTED: AT TIME OF INSPECTION - BOILE
- Masonry or façade deterioration · 39175054NSection 28-301.1 / OATH code 102 · ATOI: OBSERVED NO CONSTRUCTION ACTIVITY, HOWEVER NOTICED TREAD OF FIRST STEP IS DAMAGED, CREATING A PUBLIC SAFETY ISSUE.ALSO CRACK
- Means of egress and exit protection · 39184141XSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION OBSERVED DROP LADDER PARTIALLY OBSTRUCTED BY TREE BRANCHES ALONG WITH DEBRIS AT MULTIPLE LOCATIONS AT REAR F
- Zoning, site use or regulated sign · 39191419RSection 28-301.1 / OATH code 302 · FAILURE TO MAINTAIN BUILDING & ALL PARTS THEREOF IN CODE COMPLIANT MANNER .NOTED : AT TIME OF INSPECTION,OBSERVED AT EXPOSURE 1 ON
- Boiler device inspection and filing · 39151428MSection 28-301.1 / OATH code 254 · NAVIEN HOT WATER HEATING BOILERS INSTALLED W/PERMIT NOT SIGNED OFF PERMIT EXPIRED+SAFETY VALVES DISCHARGE INTO MANIFOLD WITHOUT AI
- Roof and weather protection · 39183002LSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN. FAILURE TO MAINTAIN REAR YARD IN A CLEAN AND ORDERLY CONDITION. EXCESSIVE CONSTRUCTION DEBRIS OBSERVED AT EXP
- Windows, doors and openings · 39163648MSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, AT EXPOSURE 1, THERE ARE VERTICAL CRACKS AT BASEME
- Roof and weather protection · 39150175ZSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. THE GUTTER LEADER HAS BEEN INSTALLED WITH CLAMPS SCREWED DIRECTLY INTO TH
- Boiler device inspection and filing · 39119663MSection 28-301.1 / OATH code 102 · I OBSERVED IN THE CELLAR AREA OF THE BOILER ROOM A FUTURE CONNECTION ON THE GAS LINE. WHICH IS PROHIBITED AND NOT CODE-COMPLIANT,
- Windows, doors and openings · 39191289HSection 28-301.1 / OATH code 102 · ATOI OBSERVED 4 WINDOW A/C UNITS ON EXP 1 AND 2 INSTALLED WITHOUT BRACKETS ON THE OUTSIDE TO PREVENT IT FROM FALLING ONTO THE PUBL
- Zoning, site use or regulated sign · 39166636ZSection 28-301.1 / OATH code 302 · AS PER PREVIOUS RCA ISSUED ON 03/11/24 BY BADGE # 3255 FAILURE TO MAINTAIN IN CODE-COMPLIANT MANNER AT EXP 1 LEFT SIDE STEEL/IRON
- Safe building maintenance · 39177875JSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. NOTED; AT LEFT SIDE OF PREMISES NEWLY PACED CONCRETE AT SHARED DRIVEWAY I
- Safe building maintenance · 39133184XSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. UPON INSPECTION OF A 2 FAMILY DWELLING LOCATED IN R3A RESIDENTIAL DISTRICT.
- Elevator safety and service status · 39140328LSection 28-301.1 / OATH code 251 · R T S.. ELEVATORS IN BUILDING OUT OF SERVICE , UP ON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE , REPAIR AND RESTORE TO S
- Roof and weather protection · 39200292KSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION OBSERVE AT EXPOSURE 1(FRONT) & 3(BACK) 3RD FLOOR SOFIT FRONT IS MISSING 10' SECTION OF SIDING, REAR SOFIT AN
- Windows, doors and openings · 39163224ZSection 28-301.1 / OATH code 202 · A/C UNITS INSTALLED AT MULTIPLE WINDOWS AT EXPO 2 AND 3 WITHOUT A PROPER SUPPORT BRACKET CREATING POTENTIAL FALL HAZARD. CONCRETE
- Construction fencing or site enclosure · 39172090RSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING AND PARTS THEREOF IN A CODE-COMPLIANT MANNER. ATOI, OBSERVED METAL CORRUGATED/CHAIN LINK FENCE IN A S
- Roof and weather protection · 39200315YSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVE AT EXPOSURE 1(FRONT) & 3(BACK) 3RD FLOOR SOFI
- Fire prevention or detection system · 39163848RSection 28-301.1 / OATH code 155 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED PER BC 903.2; 27-95
- Construction fencing or site enclosure · 39166393NSection 28-301.1 / OATH code 302 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER; AT TIME OF INSPECTION OBSERVED FENCE LEANING AND DETERIORATED WITH AREAS WI
- Safe building maintenance · 39172086YSection 28-301.1 / OATH code 302 · FAILURE TO MAINTAIN BUILDING & PARTS THEREOF IN A CODE-COMPLIANT MANNER. ATOI, OBSERVED SIDEWALK CURBCUT AT FRONT OF THE PROPERTY
- Zoning, site use or regulated sign · 39192397JSection 28-301.1 / OATH code 302 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER. NOTED; AT TIME OF INSPECTION OBSERVED AT EXPOSURE 1 THE CURB WAS ILLEGALLY
- Fire prevention or detection system · 39175286MSection 28-301.1 / OATH code 102 · OBSERVED SPRINKLER HEADS SPRAY PATTERN BEING OBSTRUCTED ON ROOF STORAGE ROOM, THIRD FLOOR LINEN CLOSET AND IN THE BASEMENT GARBAGE
- Safe building maintenance · 39164702ZSection 28-301.1 / OATH code 202 · AT TIME OF INSPECTION OBSERVED EXCESSIVE CONSTRUCTION DEBRIS TO THE FRONT OF THE BUILDING AT EXPOSURE 1., REPAIR AND/OR REPLACE
- Zoning, site use or regulated sign · 39163884YSection 28-301.1 / OATH code 202 · OBSERVED AN ADDITIONAL CURB CUT REAR OF THE BUILDING SIDEWALK CURB AT EXP: 2 OF THE PROPERTY ILLEGAL CUT SO THAT A PORTION OF THE
- Safe building maintenance · 39175635LSection 28-301.1 / OATH code 151 · 97 / X/17 CLASS 1 RESTORE TO SERVICE FOR PROPER INSPECTION BY DOB.
- Elevator device maintenance and safety devices · 39175717PSection 28-301.1 / OATH code 251 · CLASS 2: MISSING CURRENT MAINTENANCE LOG RECODS, PROVIDE ROUTINE SERVICE AND UPDATE THE LOG BOOK. CAR OPERATING PANEL KEY SWITCHES
- Structural and interior building component · 39147125NSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED STAND PIPE CLEARANCE FROM STAIRCASE. POTENTIAL HAZARD, REPAIR AND/
- Masonry or façade deterioration · 39158049YSection 28-301.1 / OATH code 102 · NOTED: ABOUT 60 LINEAR FEET BY 6' HIGH RETAINING WALL BULGING, DETERIORATED, SECTIONS CRACKED AND/OR MISSING, LEANING, AND IN DANG
- Masonry or façade deterioration · 39200445MSection 28-301.1 / OATH code 102 · OBSERVED MULTIPLE STEP CRACKING ALONG THE FRONT ENTRYWAY STEPS, AS WELL AS CRACKING IN VARIOUS OTHER LOCATIONS AROUND THE PROPERTY
- Masonry or façade deterioration · 39163450RSection 28-301.1 / OATH code 102 · EXP 2 OF BUILDING LEFT SIDE CRACKS AND 3 BRICKS MISSING, NOTHING ABOUT IN DANGER OF FALLING., REPAIR AND/REPLACE
- Sidewalk shed and public protection · 39131182NSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. SIDEWALK SHED LOCATED AT CROSS STREETS ATLANTIC AVENUE AND SARATOGA AVENU
- Safe building maintenance · 39151780LSection 28-301.1 / OATH code 139 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. O
- Masonry or façade deterioration · 39158712LSection 28-301.1 / OATH code 102 · OBSERVED AT EXP#4 STUCCO MATERIAL WAS CRACKED, MISSING, SPALLING FROM EXTERIOR WALL WITH POTENTIAL FOR PIECES TO FALL ONTO ADJACEN
- Means of egress and exit protection · 35727969ZSection 28-301.1 / OATH code 189 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER BC 1018.1(20
- Fire prevention or detection system · 35690902HSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF A AUTOMATIC SPRINKLER SYSTEM WHERE IS REQUIRED AS PER BC 903.2 AND
- Masonry or façade deterioration · 39172207LSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. PREMISES IS 5-STORY NFP PARKING GARAGE, AT TIME OF INSPECTION OBSERVED EXPO
- Vacate order scope and posting / rescission · 35685753RSection 28-301.1 / OATH code 102 · AT TIME OF INSPECTION OBSERVED REAR EXTENSION HAS COLLAPSED WITH ROOF OPEN TO THE ELEMENTS. ALSO INTERIOR WALLS AND CEILING DAMAGE
- Authorized use versus observed occupancy · 35684332YSection 28-301.1 / OATH code 189 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.LACK OF REQUIREDNUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER BC 1018.1(2008
- Fire prevention or detection system · 35684330KSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.LACK OF A AUTOMATIC SPRINKLER SYSTEM WHERE IS REQUIRED AS PER BC 903.2 AND
- Roof and weather protection · 39130059NSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER. OBSERVED A WOODEN STRUCTURE ERECTED AT ROOF LEVEL TO MAKE AS A ROOF TOP GAR
- Windows, doors and openings · 39166848KSection 28-301.1 / OATH code 202 · NOTED : UPON INSPECTION OF PROPERTY FACADE , EXPOSURE # 1 HAS SPALLING DECORATIVE STONE AND STEP CRACKS ON FIRST FLOOR AT BOTTOM O
- Masonry or façade deterioration · 39149012XSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER,NOTED AT TIME OF INSPECTION OBSERVED VISIBLE CRACKS AT BUILDING FACADE EXP
- Safe building maintenance · 35728076XSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. FAILURE TO PROVIDE NATURAL LIGHT AND VENTILATION FOR EVERY BEDROOM. NOTED:
- Gas equipment or fuel piping · 39148768LSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER; OBSERVED LAUNDRY ROOM IN CELLAR HAS GAS DRYERS NOT INSTALLED AS PER NYCBC.
- Plumbing fixture and drainage configuration · 35386491XSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: AT REAR YARD THERE IS A LOT OF DEBRIS, TOILETS, SINKS, CORRUGATED METAL CON
- Safe building maintenance · 39137538MSection 28-301.1 / OATH code 302 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED AT EXPOSURE #1. SIDEWALK CURB MODIFIED BY CUTTING SO THAT PORTION
- Authorized use versus observed occupancy · 35727973LSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. FAILURE TO PROVIDE NATURAL LIGHT AND VENTILATION FOR EVERY BEDROOM. NOTED:
- Elevator device maintenance and safety devices · 39202807JSection 28-301.1 / OATH code 251 · 1) EXPIRED CAT1 TAG. 2) MR MISSING 2026 PREVENTITIVE MAINTENANCE LOG. 3) CLEANING OF COMBUSTABLE MATERIALS IN ELEVATOR PIT. 4) SEA
- Safe building maintenance · 39157002MSection 28-301.1 / OATH code 202 · WORK WITHOUT A PERMIT. NOTED; TEMPORARY CONSTRUCTION EQUIPMENT ERECTED ON SITE WITHOUT A PERMIT. NO PERMITS ON FILE., REPAIR AND/O
- Safe building maintenance · 39176475XSection 28-301.1 / OATH code 102 · NOTED 30 FEET OF CLOTHE AWNING STEEL FRAME FELL TO GROUND AND KNOCKED INTO STEEL ROLL DOWN DOOR CAUSING IT TO COLLAPSE DURING A WI
- Masonry or façade deterioration · 39159527YSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BLDG AT EXP 1 FRONT STEPS MISSING HANDRAILS & CRACKED/BROKEN TREADS, WOOD FENCE AT CORNER OF EXP 1&2 MISSING R
- Fire prevention or detection system · 35727970XSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF A SYSTEM OF AUTOMATIC SPRINKLER WHERE IS REQUIRED PER BC 903.2 AND
- Elevator safety and service status · 39140329NSection 28-301.1 / OATH code 251 · R T S ,, ELEVATOR IN BUILDING OUT OF SERVICE, UP ON INSPECTION THE DEVICE IS FOUND TO BE OUT O0F SERVICE .. REPAIR AND RESTORE TO
- Safe building maintenance · 39151361RSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT EXPOSURE #2 SIDE ENTRANCE OPEN AND UNGUAR
- Boiler device inspection and filing · 39176083RSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTE: OBSERVED EXCESSIVE COMBUSTIBLE DEBRIS, MATERIALS, CARDBOARDS, AND OTH
- Zoning, site use or regulated sign · 39175645PSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTE: OBSERVED CURB CUT AT REAR EXPOSURE 4 AT THIS LOCATION HAS BEEN ILLEGA
- Roof and weather protection · 39193264KSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. ATOI, I OBSERVED AT THE ROOF LEVEL, THE EXIT ALARM PANIC BAR IS DEFECTED AN
- Gas equipment or fuel piping · 39192420ZSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN. I OBSERVED IN THE BASEMENT OF THE PROPERTY A FUTURE CONNECTION ON A GAS LINE TO A HOT WATER TANK. AS PER FGC
- Zoning, site use or regulated sign · 39189206KSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION OBSERVED AT FRONT OF PREMISES ILLEGAL EXTENDED
- Authorized use versus observed occupancy · 39175956MSection 28-301.1 / OATH code 126 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE. AT TIME OF INSPECTION OBSERVED IMPR
- Scaffold platform and fall protection · 39176473MSection 28-301.1 / OATH code 102 · NOTED AT REAR MAKE SHIFT SCAFFOLDING COLLAPSED ON LOT AT 1297 CARROLL ST. DAMAGING FENCE. PILED DEBRIS IS A FIRE HAZARD., REPAIR A
- Safe building maintenance · 39176269PSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN, OBSERVED PLASTIC PIPING COMMONLY REFERRED TO AS PEX CONNECTED TO THE BUILDINGS WATER SYSTEM BEING USED TO FEE
- Masonry or façade deterioration · 39175779KSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MATTER. NOTED: FACADE AT EXP-1 IN STATE OF DISREPAIR WITH STEP CRACKS AND CRACKED B
- Masonry or façade deterioration · 39191752KSection 28-301.1 / OATH code 202 · FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. NOTED AT FRONT AND RIGHT SIDE OF BUILDING. OBSERVED MULTIPLE STRESS CRACK
- Electrical installation and permit · 39189400YSection 28-301.1 / OATH code 102 · OBSERVED OPEN GAS LINE BEHIND STOVE IN APT V1. PER FGC 406.6.2 ALL VALVES AND UNUSED OUTLETS ARE CLOSED AND PLUGGED., REPAIR AND/R
- Plumbing fixture and drainage configuration · 35731929XSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT THE TIME OF INSPECTION, OBSERVED 1 SCOOTER, 1 MAP BUCKET, 4 BOXES
- Boiler device inspection and filing · 39175960PSection 28-301.1 / OATH code 102 · FAILURE TO MAINTAIN BUILDING IN A COLDE COMPLIANT MANNER AT TIME OF INSPECTION OVERSERVED INADEQUATE FIRE STOPPING IN THE BOILER R
← Previous Page 12 of 18 Next →