November 2026 NYC DOB / ECB / OATH public-record review

133-137 48 Street, Brooklyn, NY 11232 — November 2026 NYC OATH Hearing & Violation Information

The resolved public-record dataset associates 1 DOB/ECB OATH summons with 133-137 48 Street, Brooklyn, NY 11232. The source records identify fire-safety condition and a hearing date of November 23, 2026. The sections below keep the source allegations separate from explanatory analysis so an owner, buyer, realtor, attorney, lender, property manager or contractor can see what the record says, what still needs verification, and what a practical next review could involve.

Fire-safety condition

Property and hearing summary

Actual property address
133-137 48 Street, Brooklyn, NY 11232
Borough
Brooklyn
BIN
3394715
BBL
3007620060 (3/762/60)
Hearing month
November 2026
Violations on this page
1
Verified hearing date(s) in source extract
November 23, 2026
Source extract
September 18, 2026
Source information: This page was compiled from NYC DOB/ECB/OATH public-record information contained in the November 2026 resolved-property dataset and the associated DOB/ECB source extract dated September 18, 2026. Agency records may change after the source data was obtained. Hearing dates, status, penalties, correction status and agency records should be verified with NYC OATH and DOB before relying on this page.

November 2026 hearing summary

ECB/OATH summonsHearing date / timeSeverityRecord category
39163848R
Normalized: 039163848R
November 23, 2026
9:00 AM
CLASS - 1 Fire-safety condition

How the summonses fit together at this property

This page contains one resolved summons for this property. Its source allegation concerns fire-safety condition; the hearing and correction tracks should still be treated separately, because resolving the physical condition does not by itself prove the OATH/DOB record has been closed.

Violation-by-violation record and analysis

Each section first identifies what comes directly from the source extract, then separates general explanatory and strategic considerations that may require current-record research or professional review.

Violation 1

Summons 39163848R — Fire-safety condition

Normalized lookup key: 039163848R
OATH hearingNovember 23, 20269:00 AM

What DOB alleges

DOB alleges a fire-safety or fire-hazard condition. The inspector's description specifically references combustible materials.

Specific record details: combustible materials.

Full violation description from the source extract

FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED PER BC 903.2; 27-954. COMMERCIAL BUILDING OCCUPIED WITH HIGH PILES OF COMBUSTIBLE MATERIAL (WOOD) W

Issue date
October 16, 2025
Served date
October 16, 2025
Source violation type
Plumbing
Severity
CLASS - 1
Hearing status in source extract
DEFAULT
Certification status in source extract
NO COMPLIANCE RECORDED
Infraction / law references in source extract:
  • 155 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: LACK OF A SYSTE

Record-specific focus: Before choosing a correction or hearing strategy, verify the source allegation concerning failure to maintain building in code-compliant manner: lack of a system of automatic sprinklers where required per bc 903.2; 27-954. commercial building occupied with high piles of combustible material (wood) w.

What this violation means

DOB is alleging a fire-safety or fire-hazard condition, such as combustible storage, a required fire-protection component, or another condition that could affect fire spread or safe operation of the building.

What may be required to correct the condition

The cited fire-hazard condition should be removed or corrected promptly. If the condition involves a building system or rated construction rather than simple housekeeping, the applicable approved plans, fire-protection requirements and licensed-professional/trade work should be reviewed.

What the OATH hearing may involve

Hearing evidence may include photographs from the inspection date, proof of removal/repair, fire-protection plans or system records, and documentation showing who controlled the cited area.

Possible defenses or factual issues worth investigating

Verify the specific hazard, location, whether it was present as described, whether it was transient storage or a permanent condition, and whether any building-system repair or permit was required.

Documents and evidence that may be useful

  • dated photographs
  • fire-protection/system records where relevant
  • repair/removal invoices
  • approved plans if rated construction or equipment is involved
  • proof of correction
Property-specific resolution support

How Building Violation LLC may help at 133-137 48 Street, Brooklyn, NY 11232

For 133-137 48 Street, Brooklyn, NY 11232, the current source extract points to fire-safety condition. The engagement can stay focused on this summons while also checking the underlying DOB record so the physical correction and agency closeout are not treated as the same step. Building Violation LLC can scope the relevant record research, OATH hearing preparation/representation, permit or legal-use review, licensed-trade or registered-professional coordination, correction documentation and Certificate of Correction/closeout work where those steps actually apply. Detailed technical research and project work begin only after the applicable scope, authorization and payment are established.

Official government starting points

Verify the current OATH / DOB record

The source extract is a point-in-time record. Hearing dates, hearing status, penalties, correction status, permits and later agency filings can change. Use the official NYC systems below before making a decision or appearing at a hearing.