November 2026 NYC DOB / ECB / OATH public-record review

1920 West 7 Street, Brooklyn, NY 11223 — November 2026 NYC OATH Hearing & Violation Information

The resolved public-record dataset associates 3 DOB/ECB OATH summonses with 1920 West 7 Street, Brooklyn, NY 11223. The source records identify plumbing or gas work without a permit, certificate of correction / compliance filing and a hearing date of November 23, 2026. The sections below keep the source allegations separate from explanatory analysis so an owner, buyer, realtor, attorney, lender, property manager or contractor can see what the record says, what still needs verification, and what a practical next review could involve.

Plumbing or gas work without a permitCertificate of Correction / compliance filing

Property and hearing summary

Actual property address
1920 West 7 Street, Brooklyn, NY 11223
Borough
Brooklyn
BIN
3190072
BBL
3070810013 (3/7081/13)
Hearing month
November 2026
Violations on this page
3
Verified hearing date(s) in source extract
November 23, 2026
Source extract
September 18, 2026
Source information: This page was compiled from NYC DOB/ECB/OATH public-record information contained in the November 2026 resolved-property dataset and the associated DOB/ECB source extract dated September 18, 2026. Agency records may change after the source data was obtained. Hearing dates, status, penalties, correction status and agency records should be verified with NYC OATH and DOB before relying on this page.

November 2026 hearing summary

ECB/OATH summonsHearing date / timeSeverityRecord category
39182145Y
Normalized: 039182145Y
November 23, 2026
8:30 AM
CLASS - 2 Plumbing or gas work without a permit
39182146X
Normalized: 039182146X
November 23, 2026
8:30 AM
CLASS - 2 Certificate of Correction / compliance filing
39182147H
Normalized: 039182147H
November 23, 2026
8:30 AM
CLASS - 2 Plumbing or gas work without a permit

How the summonses fit together at this property

At least one summons concerns failure to file or obtain acceptance of a Certificate of Correction. That later compliance issue should be cross-checked against the underlying summons it references; paying or resolving one record does not automatically establish that the other record is closed.

Violation-by-violation record and analysis

Each section first identifies what comes directly from the source extract, then separates general explanatory and strategic considerations that may require current-record research or professional review.

Violation 1

Summons 39182145Y — Plumbing or gas work without a permit

Normalized lookup key: 039182145Y
OATH hearingNovember 23, 20268:30 AM

What DOB alleges

DOB alleges that plumbing and/or gas work was installed without the required permit. The inspector's description specifically references basement, partition walls, bedroom(s), bathroom fixtures, kitchen and Class A residential occupancy.

Specific record details: basement, partition walls, bedroom(s), bathroom fixtures, kitchen, Class A residential occupancy.

Full violation description from the source extract

WORK WITHOUT A PERMIT: AT THE TIME OF INSPECTION, OBSERVED AT BASEMENT LEVEL, FULL-HEIGHT PARTITION WALLS ERECTED TO CREATE CLASS A APARTMENT WITH BEDROOM, LIVING ROOM, KITCHEN AREA AND 3PC BATHROOM. DOB RECORD

Issue date
March 27, 2026
Served date
March 27, 2026
Source violation type
Construction
Severity
CLASS - 2
Hearing status in source extract
PENDING
Infraction / law references in source extract:
  • 201 — 28-105.1 WORK WITHOUT A PERMIT

Record-specific focus: Before choosing a correction or hearing strategy, verify the source allegation concerning work without a permit: at the time of inspection, observed at basement level, full-height partition walls erected to create class a apartment with bedroom, living room, kitchen area and 3pc bathroom. DOB record.

What this violation means

This summons concerns plumbing and/or gas work that DOB says was installed without the required permit. The cited fixtures, water/waste piping or gas piping should be compared with the legal plans and permit history.

What may be required to correct the condition

Depending on the condition, a New York City licensed master plumber and, where design work is involved, a registered design professional may need to determine whether the installation can be legalized or must be removed/restored. Permits, pressure/testing requirements, inspections and closeout may apply.

What the OATH hearing may involve

For the hearing, records showing whether the plumbing/gas scope was permitted, when it was installed, who performed it, and whether the cited fixtures or lines existed as described can be important. Correction evidence does not automatically resolve every hearing issue, but it can be relevant.

Possible defenses or factual issues worth investigating

Check existing plumbing/gas permits, approved plans, the exact fixtures and piping described, and whether the cited work is part of a broader occupancy or conversion condition. If gas piping is involved, do not assume it can remain without licensed review. Because the description identifies several physical components or locations, photographs and records should be matched to those specific details rather than submitted as general property evidence.

Documents and evidence that may be useful

  • plumbing/gas permits and approved plans
  • licensed-plumber records, invoices or test documentation
  • photographs of the cited fixtures and piping
  • inspection/sign-off records
  • proof of correction and Certificate of Correction materials where applicable
Violation 2

Summons 39182146X — Certificate of Correction / compliance filing

Normalized lookup key: 039182146X
OATH hearingNovember 23, 20268:30 AM

What DOB alleges

DOB alleges that a required Certificate of Correction was not filed or accepted for an earlier summons. The inspector's description specifically references Certificate of Correction.

Specific record details: Certificate of Correction. The description also references prior summons 35485997R.

Full violation description from the source extract

FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS, FOR VIOLATION CONTAINED IN SUMMONS #35485997R ISSUED ON 04/19/2025. AS OF DATE, NO C OF C ON FIL

Issue date
March 27, 2026
Served date
March 27, 2026
Source violation type
Construction
Severity
CLASS - 2
Hearing status in source extract
PENDING
Infraction / law references in source extract:
  • 263 — AC 28-204.4 FAIL TO COMPLY W/COMMISSIONER ORDER TO FILE CERT OF CORRECTION W/DOB

Record-specific focus: Before choosing a correction or hearing strategy, verify the source allegation concerning failure to comply with commissioner's order to file a certificate of correction with the department of buildings, for violation contained in summons #35485997r issued on 04/19/2025. as of date, no c of c on fil.

What this violation means

This summons alleges failure to comply with a prior Commissioner's order by filing an acceptable Certificate of Correction for an earlier summons. The underlying violation and the later compliance summons are separate records that should be tracked together.

What may be required to correct the condition

First identify the underlying summons referenced in the description and verify whether the physical condition was corrected, whether a Certificate of Correction was submitted, and its current DOB status. If correction is still outstanding, the underlying condition generally has to be addressed before an acceptable certification package can be completed.

What the OATH hearing may involve

The hearing may turn on the status of the underlying summons, the order to certify correction, the timing and adequacy of any submission, and whether DOB records show an accepted, rejected or missing Certificate of Correction.

Possible defenses or factual issues worth investigating

Verify the underlying summons number, correction deadline/order, any prior Certificate of Correction request, disapproval reason, and whether later agency activity changed the status. Do not assume payment of an OATH penalty closed the DOB correction requirement. Cross-reference the other order/summons number cited in the inspector narrative rather than reviewing this record in isolation.

Documents and evidence that may be useful

  • copy/status of the underlying summons
  • Certificate of Correction submission and DOB response
  • proof of physical correction such as photographs, receipts or permits
  • DOB NOW/BIS status records
  • OATH disposition and payment records if relevant
Violation 3

Summons 39182147H — Plumbing or gas work without a permit

Normalized lookup key: 039182147H
OATH hearingNovember 23, 20268:30 AM

What DOB alleges

DOB alleges that plumbing and/or gas work was installed without the required permit. The inspector's description specifically references basement, bathroom fixtures, plumbing lines/fixtures and Class A residential occupancy.

Specific record details: basement, bathroom fixtures, plumbing lines/fixtures, Class A residential occupancy.

Full violation description from the source extract

WORK WITHOUT A PERMIT: AT THE TIME OF INSPECTION, OBSERVED A BASEMENT LEVEL, CLASS A APARTMENT WITH 3PC BATHROOM. DOB RECORDS INDICATE NO PERMIT ON FILE FOR PLUMBING WORK DONE FOR BATHROOM., OBTAIN ALL PERMITS;

Issue date
March 27, 2026
Served date
March 27, 2026
Source violation type
Construction
Severity
CLASS - 2
Hearing status in source extract
PENDING
Infraction / law references in source extract:
  • 201 — 28-105.1 WORK WITHOUT A PERMIT

Record-specific focus: Before choosing a correction or hearing strategy, verify the source allegation concerning work without a permit: at the time of inspection, observed a basement level, class a apartment with 3pc bathroom. DOB records indicate no permit on file for plumbing work done for bathroom.

What this violation means

This summons concerns plumbing and/or gas work that DOB says was installed without the required permit. The cited fixtures, water/waste piping or gas piping should be compared with the legal plans and permit history.

What may be required to correct the condition

Depending on the condition, a New York City licensed master plumber and, where design work is involved, a registered design professional may need to determine whether the installation can be legalized or must be removed/restored. Permits, pressure/testing requirements, inspections and closeout may apply.

What the OATH hearing may involve

For the hearing, records showing whether the plumbing/gas scope was permitted, when it was installed, who performed it, and whether the cited fixtures or lines existed as described can be important. Correction evidence does not automatically resolve every hearing issue, but it can be relevant.

Possible defenses or factual issues worth investigating

Check existing plumbing/gas permits, approved plans, the exact fixtures and piping described, and whether the cited work is part of a broader occupancy or conversion condition. If gas piping is involved, do not assume it can remain without licensed review. Because the description identifies several physical components or locations, photographs and records should be matched to those specific details rather than submitted as general property evidence.

Documents and evidence that may be useful

  • plumbing/gas permits and approved plans
  • licensed-plumber records, invoices or test documentation
  • photographs of the cited fixtures and piping
  • inspection/sign-off records
  • proof of correction and Certificate of Correction materials where applicable
Property-specific resolution support

How Building Violation LLC may help at 1920 West 7 Street, Brooklyn, NY 11223

For 1920 West 7 Street, Brooklyn, NY 11223, the current source extract points to plumbing or gas work without a permit, certificate of correction / compliance filing. Because this property has multiple summonses, the practical advantage is coordinating record research, hearing preparation and correction work as one property matter while still tracking each summons separately. Building Violation LLC can scope the relevant record research, OATH hearing preparation/representation, permit or legal-use review, licensed-trade or registered-professional coordination, correction documentation and Certificate of Correction/closeout work where those steps actually apply. Detailed technical research and project work begin only after the applicable scope, authorization and payment are established.

Official government starting points

Verify the current OATH / DOB record

The source extract is a point-in-time record. Hearing dates, hearing status, penalties, correction status, permits and later agency filings can change. Use the official NYC systems below before making a decision or appearing at a hearing.