November 2026 NYC DOB / ECB / OATH public-record review

38-44 State Street, Brooklyn, NY 11201 — November 2026 NYC OATH Hearing & Violation Information

The resolved public-record dataset associates 2 DOB/ECB OATH summonses with 38-44 State Street, Brooklyn, NY 11201. The source records identify work not conforming to approved documents, elevator compliance / maintenance and a hearing date of November 25, 2026. The sections below keep the source allegations separate from explanatory analysis so an owner, buyer, realtor, attorney, lender, property manager or contractor can see what the record says, what still needs verification, and what a practical next review could involve.

Work not conforming to approved documentsElevator compliance / maintenance

Property and hearing summary

Actual property address
38-44 State Street, Brooklyn, NY 11201
Borough
Brooklyn
BIN
3002261
BBL
3002580131 (3/258/131)
Hearing month
November 2026
Violations on this page
2
Verified hearing date(s) in source extract
November 25, 2026
Source extract
September 18, 2026
Source information: This page was compiled from NYC DOB/ECB/OATH public-record information contained in the November 2026 resolved-property dataset and the associated DOB/ECB source extract dated September 18, 2026. Agency records may change after the source data was obtained. Hearing dates, status, penalties, correction status and agency records should be verified with NYC OATH and DOB before relying on this page.

November 2026 hearing summary

ECB/OATH summonsHearing date / timeSeverityRecord category
39559218N
Normalized: 039559218N
November 25, 2026
10:30 AM
CLASS - 1 Work not conforming to approved documents
39559219P
Normalized: 039559219P
November 25, 2026
10:30 AM
CLASS - 2 Elevator compliance / maintenance

How the summonses fit together at this property

This property has 2 separate summonses. Some can be coordinated as one property matter for research, correction planning and document gathering, but each summons remains tied to its own allegation and hearing information. Several descriptions point to the same area (elevator), which is a sign the summonses may be factually connected. The practical goal is to avoid solving only one piece of the property record while another summons or correction requirement remains open.

Violation-by-violation record and analysis

Each section first identifies what comes directly from the source extract, then separates general explanatory and strategic considerations that may require current-record research or professional review.

Violation 1

Summons 39559218N — Work not conforming to approved documents

Normalized lookup key: 039559218N
OATH hearingNovember 25, 202610:30 AM

What DOB alleges

DOB alleges that field work did not conform to the approved construction documents. The inspector's description specifically references cellar, elevator equipment and scaffold/shoring.

Specific record details: cellar, elevator equipment, scaffold/shoring.

Full violation description from the source extract

ATOI OBSERVED A SYSTEMS SCAFFOLD IN UNIT 1 FROM THE CELLAR TO THE 5TH FLOOR IN THE ELEVATOR SHAFT WHEN ASKED FOR SCAFFOLDING DRAWINGS NONE WERE PROVIDED THAT REFLECT THIS SYSTEMS SCAFFOLDING IN THE ELEVATOR SHA

Issue date
September 16, 2026
Served date
September 16, 2026
Source violation type
Construction
Severity
CLASS - 1
Hearing status in source extract
PENDING
Infraction / law references in source extract:
  • 182 — 28-105.12.2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROV

Record-specific focus: Before choosing a correction or hearing strategy, verify the source allegation concerning atoi observed a systems scaffold in unit 1 from the cellar to the 5th floor in the elevator shaft when asked for scaffolding drawings none were provided that reflect this systems scaffolding in the elevator sha.

What this violation means

DOB is alleging that work in progress did not match the approved construction documents or amendments. Even permitted work can be cited if the field condition departs materially from the approved plan set.

What may be required to correct the condition

The field condition should be compared line-by-line with the approved plans. Depending on what is found, the project may need to be restored to the approved design or the plans may need to be amended and re-approved before the work continues or is signed off.

What the OATH hearing may involve

Hearing evidence can include the approved plan sheets in effect on the inspection date, revision history, photographs of the field condition, professional reports and proof that the discrepancy was corrected or formally amended.

Possible defenses or factual issues worth investigating

Identify the exact plan sheet/detail DOB says was violated, confirm which approved set controlled on the inspection date, and determine whether the field condition was temporary, incomplete, or actually inconsistent with the approval. Because the description identifies several physical components or locations, photographs and records should be matched to those specific details rather than submitted as general property evidence.

Documents and evidence that may be useful

  • DOB-approved construction documents and amendments
  • field photographs
  • architect/engineer field reports
  • permit and inspection history
  • revised approvals or restoration evidence
Violation 2

Summons 39559219P — Elevator compliance / maintenance

Normalized lookup key: 039559219P
OATH hearingNovember 25, 202610:30 AM

What DOB alleges

DOB alleges an elevator maintenance, equipment or operational safety condition. The inspector's description specifically references elevator equipment and scaffold/shoring.

Specific record details: elevator equipment, scaffold/shoring.

Full violation description from the source extract

BC 3314.1 & 3314.4.4.1 SAFE WORKING ORDER. OBSERVED SYSTEMS SCAFFOLD AT ELEVATOR SHAFT W/ MISSING TOE BOARDS AS REQUIRED IN MANUFACTURER SPECS AS WELL AS THE SCAFFOLD NOT BEING NAILED DOWN TO THE MUDSILLS IN OR

Issue date
September 16, 2026
Served date
September 16, 2026
Source violation type
Unknown
Severity
CLASS - 2
Hearing status in source extract
PENDING
Infraction / law references in source extract:
  • 2P7

Record-specific focus: Before choosing a correction or hearing strategy, verify the source allegation concerning bc 3314.1 & 3314.4.4.1 safe working order. observed systems scaffold at elevator shaft w/ missing toe boards as required in manufacturer specs as well as the scaffold not being nailed down to the mudsills in or.

What this violation means

This summons concerns elevator equipment, maintenance or operational safety. Elevator violations are often tied to a specific device condition and should be evaluated by the responsible licensed elevator agency or other qualified elevator professional.

What may be required to correct the condition

The cited elevator component or maintenance issue should be inspected and corrected by the appropriate licensed elevator contractor/agency. Depending on the record, DOB NOW: Safety filings, tests, inspection documentation or proof of correction may also be needed.

What the OATH hearing may involve

At OATH, the equipment condition on the inspection date, maintenance/test records, device history, photographs or service reports, and proof of timely correction may be relevant.

Possible defenses or factual issues worth investigating

Confirm the device/elevator involved, the exact cited defect, maintenance and test history, whether the elevator was taken out of service if required, and whether later inspection or repair records document the condition.

Documents and evidence that may be useful

  • elevator maintenance and service logs
  • inspection/test records
  • licensed-elevator-contractor repair documentation
  • photographs where useful
  • DOB NOW/BIS device and violation records
Property-specific resolution support

How Building Violation LLC may help at 38-44 State Street, Brooklyn, NY 11201

For 38-44 State Street, Brooklyn, NY 11201, the current source extract points to work not conforming to approved documents, elevator compliance / maintenance. Because this property has multiple summonses, the practical advantage is coordinating record research, hearing preparation and correction work as one property matter while still tracking each summons separately. Building Violation LLC can scope the relevant record research, OATH hearing preparation/representation, permit or legal-use review, licensed-trade or registered-professional coordination, correction documentation and Certificate of Correction/closeout work where those steps actually apply. Detailed technical research and project work begin only after the applicable scope, authorization and payment are established.

Official government starting points

Verify the current OATH / DOB record

The source extract is a point-in-time record. Hearing dates, hearing status, penalties, correction status, permits and later agency filings can change. Use the official NYC systems below before making a decision or appearing at a hearing.