November 2026 NYC DOB / ECB / OATH public-record review

4324 Avenue D, Brooklyn, NY 11203 — November 2026 NYC OATH Hearing & Violation Information

The resolved public-record dataset associates 4 DOB/ECB OATH summonses with 4324 Avenue D, Brooklyn, NY 11203. The source records identify sidewalk shed / temporary construction protection, dob/oath code-compliance issue, fire-safety condition and a hearing date of November 18, 2026. The sections below keep the source allegations separate from explanatory analysis so an owner, buyer, realtor, attorney, lender, property manager or contractor can see what the record says, what still needs verification, and what a practical next review could involve.

Sidewalk shed / temporary construction protectionDOB/OATH code-compliance issueFire-safety condition

Property and hearing summary

Actual property address
4324 Avenue D, Brooklyn, NY 11203
Borough
Brooklyn
BIN
3430194
BBL
3049770010 (3/4977/10)
Hearing month
November 2026
Violations on this page
4
Verified hearing date(s) in source extract
November 18, 2026
Source extract
September 18, 2026
Source information: This page was compiled from NYC DOB/ECB/OATH public-record information contained in the November 2026 resolved-property dataset and the associated DOB/ECB source extract dated September 18, 2026. Agency records may change after the source data was obtained. Hearing dates, status, penalties, correction status and agency records should be verified with NYC OATH and DOB before relying on this page.

November 2026 hearing summary

ECB/OATH summonsHearing date / timeSeverityRecord category
39558925H
Normalized: 039558925H
November 18, 2026
10:30 AM
CLASS - 1 Sidewalk shed / temporary construction protection
39558930M
Normalized: 039558930M
November 18, 2026
8:30 AM
CLASS - 1 DOB/OATH code-compliance issue
39558931Y
Normalized: 039558931Y
November 18, 2026
9:30 AM
CLASS - 2 Fire-safety condition
39559106Z
Normalized: 039559106Z
November 18, 2026
9:30 AM
CLASS - 2 Sidewalk shed / temporary construction protection

How the summonses fit together at this property

This property has 4 separate summonses. Some can be coordinated as one property matter for research, correction planning and document gathering, but each summons remains tied to its own allegation and hearing information. The practical goal is to avoid solving only one piece of the property record while another summons or correction requirement remains open.

Violation-by-violation record and analysis

Each section first identifies what comes directly from the source extract, then separates general explanatory and strategic considerations that may require current-record research or professional review.

Violation 1

Summons 39558925H — Sidewalk shed / temporary construction protection

Normalized lookup key: 039558925H
OATH hearingNovember 18, 202610:30 AM

What DOB alleges

DOB alleges a defect or code-compliance problem involving sidewalk-shed/scaffold protection. The inspector's description specifically references scaffold/shoring.

Specific record details: scaffold/shoring.

Full violation description from the source extract

AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE FAILURE TO ADEQUATELY INSTALL SUPPORTED SCAFFOLD@EXP. 3, (3314.9.1-3314.9.4) MISSING MULTIPLE SAFETY COMPONENTS; FULLY PLANK DECKING, TOE-BOARDS, GUARDRAILS, &

Issue date
September 8, 2026
Served date
September 9, 2026
Source violation type
Unknown
Severity
CLASS - 1
Hearing status in source extract
PENDING
Infraction / law references in source extract:
  • 1P7

Record-specific focus: Before choosing a correction or hearing strategy, verify the source allegation concerning at the time of my inspection observed active site failure to adequately install supported scaffold@exp. 3, (3314.9.1-3314.9.4) missing multiple safety components; fully plank decking, toe-boards, guardrails, &.

What this violation means

The allegation concerns a sidewalk shed, scaffold, overhead protection or related temporary construction protection that DOB says did not meet required safety or maintenance conditions.

What may be required to correct the condition

The cited shed/scaffold condition should be inspected against the approved temporary-construction documents and Chapter 33 requirements. Correction may involve immediate repair, lighting, edge protection, anchorage, dimensions, housekeeping or permit/document updates depending on the allegation.

What the OATH hearing may involve

At OATH, dated site photographs, the approved shed/scaffold drawings or permit, inspection logs, contractor records and proof of prompt correction can help establish what condition existed and how it was addressed.

Possible defenses or factual issues worth investigating

Match the inspector's cited location and component to the approved temporary-construction setup, determine whether the condition was transient or ongoing, and verify permit/status information for the protection system.

Documents and evidence that may be useful

  • sidewalk-shed/scaffold permit and approved drawings
  • site photographs from the inspection period
  • daily/site-safety inspection logs
  • contractor repair records
  • DOB inspection/reinspection records
Violation 2

Summons 39558930M — DOB/OATH code-compliance issue

Normalized lookup key: 039558930M
OATH hearingNovember 18, 20268:30 AM

What DOB alleges

DOB alleges a dob/oath code-compliance issue condition. The inspector's description specifically references cellar and first floor.

Specific record details: cellar, first floor.

Full violation description from the source extract

AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE FAILED TO INSTALL HANDRAILS BETWEEN 1ST FLOOR & CELLAR LEVEL (BC 3301.2 & 27-1009(A)). SITE MUST ADEQAUTELY INSTALL HANDRAILS FOR ALL ACTIVE WORKERS, EMT PERSON

Issue date
September 8, 2026
Served date
September 9, 2026
Source violation type
Construction
Severity
CLASS - 1
Hearing status in source extract
PENDING
Infraction / law references in source extract:
  • 120 — BC 3301.2,27-1009(A) FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY

Record-specific focus: Before choosing a correction or hearing strategy, verify the source allegation concerning at the time of my inspection observed active site failed to install handrails between 1st floor & cellar level (bc 3301.2 & 27-1009(a)). site must adeqautely install handrails for all active workers, emt person.

What this violation means

This summons is a DOB/OATH code-compliance matter. The source description—not the category label alone—should control the factual review, because similarly classified summonses can involve very different physical conditions.

What may be required to correct the condition

Start by verifying the cited condition against the current site and DOB record, then identify the qualified contractor, licensed trade or registered design professional—if any—needed for correction, permits, inspection or closeout.

What the OATH hearing may involve

Hearing preparation should focus on the facts alleged, the condition on the inspection date, permit/approval history, responsibility for the cited area, and any reliable evidence of correction or contrary facts.

Possible defenses or factual issues worth investigating

Review the exact allegation, cited code section, location, permit/approval history and any later agency activity. Avoid assuming a defense or correction path before the current record is checked.

Documents and evidence that may be useful

  • the summons and current OATH status
  • dated photographs
  • relevant DOB permits/plans/violations
  • contracts, invoices or professional reports tied to the cited condition
  • proof of correction where available
Violation 3

Summons 39558931Y — Fire-safety condition

Normalized lookup key: 039558931Y
OATH hearingNovember 18, 20269:30 AM

What DOB alleges

DOB alleges a fire-safety or fire-hazard condition. The inspector's description specifically references combustible materials and debris/housekeeping.

Specific record details: combustible materials, debris/housekeeping.

Full violation description from the source extract

AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE FAILED TO ADEQUATELY MAINTAIN HOUSEKEEPING DUTIES(BC 3303.4 & 27-1018)SITE @ EXP. 1,2&3 WITH OVERLOADED DEBRIS, COMBUSTIBLE MATERIAL, & EXCESSIVE AMOUNT TRIPPIN

Issue date
September 8, 2026
Served date
September 9, 2026
Source violation type
Construction
Severity
CLASS - 2
Hearing status in source extract
PENDING
Infraction / law references in source extract:
  • 212 — BC 3303.4,27-1018 FAIL TO MAINTAIN ADEQUATE HSEKEEPING PER SECTIONS REQUIREMENTS

Record-specific focus: Before choosing a correction or hearing strategy, verify the source allegation concerning at the time of my inspection observed active site failed to adequately maintain housekeeping duties(bc 3303.4 & 27-1018)site @ exp. 1,2&3 with overloaded debris, combustible material, & excessive amount trippin.

What this violation means

DOB is alleging a fire-safety or fire-hazard condition, such as combustible storage, a required fire-protection component, or another condition that could affect fire spread or safe operation of the building.

What may be required to correct the condition

The cited fire-hazard condition should be removed or corrected promptly. If the condition involves a building system or rated construction rather than simple housekeeping, the applicable approved plans, fire-protection requirements and licensed-professional/trade work should be reviewed.

What the OATH hearing may involve

Hearing evidence may include photographs from the inspection date, proof of removal/repair, fire-protection plans or system records, and documentation showing who controlled the cited area.

Possible defenses or factual issues worth investigating

Verify the specific hazard, location, whether it was present as described, whether it was transient storage or a permanent condition, and whether any building-system repair or permit was required.

Documents and evidence that may be useful

  • dated photographs
  • fire-protection/system records where relevant
  • repair/removal invoices
  • approved plans if rated construction or equipment is involved
  • proof of correction
Violation 4

Summons 39559106Z — Sidewalk shed / temporary construction protection

Normalized lookup key: 039559106Z
OATH hearingNovember 18, 20269:30 AM

What DOB alleges

DOB alleges a defect or code-compliance problem involving sidewalk-shed/scaffold protection. The inspector's description specifically references scaffold/shoring.

Specific record details: scaffold/shoring.

Full violation description from the source extract

NOTE: AT TIME OF INSPECTION, I OBSERVED ON GOING WORK ON THE SUPPORTED SCAFFOLD AND OTHER CONSTRUCTION OPERATIONS WITHIN THE SITE, UPON REQUEST AND REVIEWED OF THE DEPARTMENT RECORDS FOR THE REQUIRED AFTER HOUR

Issue date
September 12, 2026
Served date
September 12, 2026
Source violation type
Construction
Severity
CLASS - 2
Hearing status in source extract
PENDING
Infraction / law references in source extract:
  • 2C2 — 28-105.1 WORK AFTER HOURS W/O VARIANCE PERMIT CONTRARY TO 28-105.12.5

Record-specific focus: Before choosing a correction or hearing strategy, verify the source allegation concerning observed ON GOING WORK ON THE SUPPORTED SCAFFOLD AND OTHER CONSTRUCTION OPERATIONS WITHIN THE SITE, UPON REQUEST AND REVIEWED OF THE DEPARTMENT RECORDS FOR THE REQUIRED AFTER HOUR.

What this violation means

The allegation concerns a sidewalk shed, scaffold, overhead protection or related temporary construction protection that DOB says did not meet required safety or maintenance conditions.

What may be required to correct the condition

The cited shed/scaffold condition should be inspected against the approved temporary-construction documents and Chapter 33 requirements. Correction may involve immediate repair, lighting, edge protection, anchorage, dimensions, housekeeping or permit/document updates depending on the allegation.

What the OATH hearing may involve

At OATH, dated site photographs, the approved shed/scaffold drawings or permit, inspection logs, contractor records and proof of prompt correction can help establish what condition existed and how it was addressed.

Possible defenses or factual issues worth investigating

Match the inspector's cited location and component to the approved temporary-construction setup, determine whether the condition was transient or ongoing, and verify permit/status information for the protection system.

Documents and evidence that may be useful

  • sidewalk-shed/scaffold permit and approved drawings
  • site photographs from the inspection period
  • daily/site-safety inspection logs
  • contractor repair records
  • DOB inspection/reinspection records
Property-specific resolution support

How Building Violation LLC may help at 4324 Avenue D, Brooklyn, NY 11203

For 4324 Avenue D, Brooklyn, NY 11203, the current source extract points to sidewalk shed / temporary construction protection, dob/oath code-compliance issue, fire-safety condition. Because this property has multiple summonses, the practical advantage is coordinating record research, hearing preparation and correction work as one property matter while still tracking each summons separately. Building Violation LLC can scope the relevant record research, OATH hearing preparation/representation, permit or legal-use review, licensed-trade or registered-professional coordination, correction documentation and Certificate of Correction/closeout work where those steps actually apply. Detailed technical research and project work begin only after the applicable scope, authorization and payment are established.

Official government starting points

Verify the current OATH / DOB record

The source extract is a point-in-time record. Hearing dates, hearing status, penalties, correction status, permits and later agency filings can change. Use the official NYC systems below before making a decision or appearing at a hearing.