Unpermitted electrical work — ECB/OATH summons 39205223J
Normalized ten-character lookup: 039205223J (infraction 1C9)
Source allegation and actual cited law
DOB alleges electrical work or equipment without a required electrical permit or compliant installation. Key locations/components named in the source: stairs or landings, electrical installation, door or exit route.
Inspector narrative as preserved in source data — potentially incomplete
OBSERVED AT BSEMENT ENTRY NEW LECTRICAL SERVICE WITH METERPANS AND CONDUITS. ALSO AT FIRST FLOOR ENTRY FROM DOOR, AT STAIR OBSERVED NEW BX ELECTRICAL WIRING. OPEN ENDED BX WITH WIRE NUTS, WIRES HANGING FROM CEI
The supplied record stops at its extract limit and may omit the rest of the inspector narrative. Obtain the complete original summons before making a factual or legal decision.
- 1C9 — 27-3018(B) ELECTRICAL WORK WITHOUT A PERMIT
- Issue date
- September 23, 2026
- Service date
- September 23, 2026
- Source severity
- CLASS - 1
- Source violation type
- Unknown
- Hearing status in extract
- PENDING
- DOB/ECB status in extract
- ACTIVE
- Correction certification in extract
- Not recorded
- Penalty field in extract
- $2,500.00
- Balance field in extract
- $2,500.00
Penalty and balance are fields in the supplied November 10 extract—not independently verified current fines, final adjudications or amounts presently owed.
Safety priority: Class 1 in source — treat any alleged immediately hazardous condition as urgent; verify specific DOB correction requirements.
What the alleged violation means at 1329 41 Street, Brooklyn, NY 11218
Identify the circuits, panels, wiring or devices actually cited and review the electrical filing/inspection record for the original installation date. Key locations/components named in the source: stairs or landings, electrical installation, door or exit route. Record-specific inspection detail: Inspector text begins: “OBSERVED AT BSEMENT ENTRY NEW LECTRICAL SERVICE WITH METERPANS AND CONDUITS. ALSO AT FIRST FLOOR ENTRY FROM DOOR, AT STAIR OBSERVED NEW BX ELECTRICAL WIRIN…”
Possible defense questions and factual disputes to investigate
The following are issues to verify, not assurances that a defense applies to summons 039205223J.
- Whether the cited work required an electrical permit at the relevant time
- Whether a licensed electrician had already filed, inspected or signed off the cited work
- Whether the described installation is correctly located and attributed
- Compare the original summons, issue/service dates and the complete inspector narrative with each document; do not assume any potential defense is established without proof.
Correction and DOB closeout strategy
- Have safety-sensitive wiring or service conditions reviewed by a qualified licensed electrician.
- If needed, arrange appropriate permits, inspections, repairs or removal and obtain required DOB closeout.
Determine whether DOB requires a Certificate of Correction, a separate reinspection, application/permit sign-off or an order-lift. An OATH outcome, a paid fine and physical correction are separate issues.
Evidence and documents tailored to this allegation
- stair/landing measurements and dated photos or approved egress plans
- licensed electrician report and electrical filing history
- door/exit photographs and approved egress plans
- electrical permit/job history and inspection results
- licensed electrician invoices, test reports and sign-offs
- dated photos of panels, circuits or fixtures referenced
- approved electrical drawings and DOB correspondence
Pending in source: what to verify before acting
The November 10 extract lists the hearing as PENDING. Confirm its present scheduling, appearance method, adjournment/settlement rules and evidence deadlines directly with OATH.
Need a summons-specific action plan? For 039205223J, Building Violation LLC can scope electrical-summons hearing support and licensed-electrician filing coordination after reviewing the actual notice and current DOB/OATH record.