NYC DOB / ECB / OATH hearings · verified property resolution

2226 1 Avenue, Manhattan, NY 10029 — Boiler / gas / plumbing compliance and December 2026 OATH Hearing Details

The November 10, 2026 verified-property dataset associates 2 DOB/ECB/OATH summonses with 2226 1 Avenue, Manhattan, NY 10029 and source-listed date December 17, 2026. Recorded concerns include boiler / gas / plumbing compliance. Below are the exact source identifiers and allegations, followed by issue-specific defense checks, correction options and evidence needed for a responsible review.

Boiler / gas / plumbing compliance

Verified premises, hearing and enforcement snapshot

Verified premises address
2226 1 Avenue, Manhattan, NY 10029
Borough
Manhattan
BIN
1079371
BBL
1017080003
Source summonses
2
Hearing dates in source
December 17, 2026
Source snapshot
November 10, 2026
Address verification method
PAD exact BIN

Official PAD aliases and building ranges: 2226 1 AVENUE; 2226A 1 AVENUE; 2226B 1 AVENUE; 2228 1 AVENUE; 2230 1 AVENUE

Source and authorship: Building Violation LLC prepared this independent property-record explanation using a November 10, 2026 DOB/OATH source extract and verified BIN/BBL property matching. The issue analysis is editorial guidance generated from source allegations and cited laws, not a new inspection or legal determination. The source sometimes abbreviates inspector text. This is not a live OATH calendar; verify dates, appearance instructions, dispositions, monetary fields and compliance directly with NYC.

What merits immediate verification: one or more Class 1 source allegations; one or more possibly shortened inspector narratives. Read the current OATH and DOB records before acting.

What is the December 2026 OATH hearing for at 2226 1 Avenue, Manhattan, NY 10029?

The uploaded record lists 2 summonses, including 039124812N (boiler / gas / plumbing compliance), 039124824K (boiler / gas / plumbing compliance). The source-listed hearing date: December 17, 2026. These are allegations and dated extract fields; the current official notices determine the actual appearance obligation and disposition.

What should the owner or respondent do first?

Verify the status of each normalized summons with OATH, obtain the complete inspector narrative and cited order/permit records, address immediate hazards, and assemble dated evidence matched to each allegation. A Certificate of Correction or other DOB closeout may remain necessary even after an OATH hearing or payment.

December 2026 summonses and listed hearing times

Summons / lookupSource hearing date / timeSeverityRecorded subjectSource disposition
39124812N
039124812N
1:00 PM
CLASS - 2Boiler / gas / plumbing compliancePENDING
39124824K
039124824K
1:00 PM
CLASS - 1Boiler / gas / plumbing compliancePENDING

How the 2 recorded summonses relate at 2226 1 Avenue, Manhattan, NY 10029

The verified property matching links 2 distinct summonses to 2226 1 Avenue, Manhattan, NY 10029. They may share a property and documents, but the dataset does not establish that they arose from one inspection, one condition or one respondent. Review each summons independently.

Boiler / gas / plumbing compliance (2): source summons 039124812N, 039124824K. These charges may share a single technical investigation or corrected condition only if the actual cited locations and inspection facts match.

Shared source issue date: 2 summonses list September 13, 2024 as their issue date. Compare inspection times, sites and inspector observations before deciding whether they are factually connected.

Coordination checklist: build one property evidence folder with a separate subfolder, hearing/disposition verification and correction tracking sheet for each normalized summons number. Share drawings or photos across tickets only when the same physical facts are documented.

Each violation: allegation, defense issues, correction strategy and supporting documents

Source wording is distinguished from potential actions. These are investigatory prompts, not legal advice, guaranteed defenses or promises of DOB acceptance.

Summons 1 of the source-linked property

Boiler / gas / plumbing compliance — ECB/OATH summons 39124812N

Normalized ten-character lookup: 039124812N (infraction 202)

November 10 source-listed hearing1:00 PM

Source allegation and actual cited law

The citation relates to gas, plumbing, boiler or mechanical equipment, permits or inspections. Key locations/components named in the source: cellar or basement area, gas or boiler equipment.

Inspector narrative as preserved in source data — potentially incomplete

OBSERVED IN BASEMENT FIVE OPEN ENDED GAS LINES , FUTURES ON GAS LINES, USING LAMP WICK ON GAS LINES AND HOT WATER HEATER TEMPERATURE RELIEF VALVE DISCHARGE PIPE IS NOT INSTALLED WHICH IS CONTRARY TO CODE SECTIO

The supplied record stops at its extract limit and may omit the rest of the inspector narrative. Obtain the complete original summons before making a factual or legal decision.

Recorded infraction numbers and cited legal provisions:
  • 202 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER
Issue date
September 13, 2024
Service date
September 13, 2024
Source severity
CLASS - 2
Source violation type
Construction
Hearing status in extract
PENDING
DOB/ECB status in extract
ACTIVE
Correction certification in extract
Not recorded
Penalty field in extract
$655.00
Balance field in extract
$655.00

Penalty and balance are fields in the supplied November 10 extract—not independently verified current fines, final adjudications or amounts presently owed.

What the alleged violation means at 2226 1 Avenue, Manhattan, NY 10029

Identify the cited installation, system or report cycle and compare it with the building’s approved equipment and trade filings. Key locations/components named in the source: cellar or basement area, gas or boiler equipment. Record-specific inspection detail: Inspector text begins: “OBSERVED IN BASEMENT FIVE OPEN ENDED GAS LINES , FUTURES ON GAS LINES, USING LAMP WICK ON GAS LINES AND HOT WATER HEATER TEMPERATURE RELIEF VALVE DISCHARGE…”

Possible defense questions and factual disputes to investigate

The following are issues to verify, not assurances that a defense applies to summons 039124812N.

  • Whether a required permit, inspection or periodic filing actually applied at that time
  • Whether licensed-trade repairs, test results or sign-offs already address the cited item
  • Whether the exact equipment and property location match the notice
  • Compare the original summons, issue/service dates and the complete inspector narrative with each document; do not assume any potential defense is established without proof.

Correction and DOB closeout strategy

  • Have potentially dangerous gas or boiler conditions checked by a properly licensed professional promptly.
  • Arrange the correct mechanical/plumbing/gas filing, inspection, repairs or report submission and closeout.

Determine whether DOB requires a Certificate of Correction, a separate reinspection, application/permit sign-off or an order-lift. An OATH outcome, a paid fine and physical correction are separate issues.

Evidence and documents tailored to this allegation

  • dated cellar/basement photos and approved basement floor plan
  • licensed-trade test results and equipment/permit records
  • plumbing/gas/boiler permit and inspection history
  • licensed contractor reports, tests and paid invoices
  • equipment photographs, serials or specifications
  • DOB/utility correspondence and accepted sign-offs

Pending in source: what to verify before acting

The November 10 extract lists the hearing as PENDING. Confirm its present scheduling, appearance method, adjournment/settlement rules and evidence deadlines directly with OATH.

Need a summons-specific action plan? For 039124812N, Building Violation LLC can scope mechanical/plumbing violation research and licensed-trade correction coordination after reviewing the actual notice and current DOB/OATH record.

Request help with boiler / gas / plumbing compliance at 2226 1 Avenue, Manhattan, NY 10029
Summons 2 of the source-linked property

Boiler / gas / plumbing compliance — ECB/OATH summons 39124824K

Normalized ten-character lookup: 039124824K (infraction 154)

November 10 source-listed hearing1:00 PM

Source allegation and actual cited law

The citation relates to gas, plumbing, boiler or mechanical equipment, permits or inspections. Key locations/components named in the source: gas or boiler equipment, elevator or lift.

Inspector narrative as preserved in source data — potentially incomplete

B154 CEASED USE TWO GAS HOT WATER HEATERS MODEL #A/O SMITH FCG-75 400 ,DUE TO HAZARDOUS CONDITIONS, OPEN FLUE FROM BOILERS TO CHIMNEY BREECHING/CALL 2126020580 TO LIFT CEASE USE WHEN ALL HAZARDOUS CONDITIONS HA

The supplied record stops at its extract limit and may omit the rest of the inspector narrative. Obtain the complete original summons before making a factual or legal decision.

Recorded infraction numbers and cited legal provisions:
  • 154 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: SERVICE EQUIPME
Issue date
September 13, 2024
Service date
September 13, 2024
Source severity
CLASS - 1
Source violation type
Boilers
Hearing status in extract
PENDING
DOB/ECB status in extract
ACTIVE
Correction certification in extract
Not recorded
Penalty field in extract
$1,280.00
Balance field in extract
$1,280.00

Penalty and balance are fields in the supplied November 10 extract—not independently verified current fines, final adjudications or amounts presently owed.

Safety priority: Class 1 in source — treat any alleged immediately hazardous condition as urgent; verify specific DOB correction requirements.

What the alleged violation means at 2226 1 Avenue, Manhattan, NY 10029

Identify the cited installation, system or report cycle and compare it with the building’s approved equipment and trade filings. Key locations/components named in the source: gas or boiler equipment, elevator or lift. Record-specific inspection detail: Inspector text begins: “B154 CEASED USE TWO GAS HOT WATER HEATERS MODEL #A/O SMITH FCG-75 400 ,DUE TO HAZARDOUS CONDITIONS, OPEN FLUE FROM BOILERS TO CHIMNEY BREECHING/CALL 212602…”

Possible defense questions and factual disputes to investigate

The following are issues to verify, not assurances that a defense applies to summons 039124824K.

  • Whether a required permit, inspection or periodic filing actually applied at that time
  • Whether licensed-trade repairs, test results or sign-offs already address the cited item
  • Whether the exact equipment and property location match the notice
  • Compare the original summons, issue/service dates and the complete inspector narrative with each document; do not assume any potential defense is established without proof.

Correction and DOB closeout strategy

  • Have potentially dangerous gas or boiler conditions checked by a properly licensed professional promptly.
  • Arrange the correct mechanical/plumbing/gas filing, inspection, repairs or report submission and closeout.

Determine whether DOB requires a Certificate of Correction, a separate reinspection, application/permit sign-off or an order-lift. An OATH outcome, a paid fine and physical correction are separate issues.

Evidence and documents tailored to this allegation

  • licensed-trade test results and equipment/permit records
  • device inspection and service documentation
  • plumbing/gas/boiler permit and inspection history
  • licensed contractor reports, tests and paid invoices
  • equipment photographs, serials or specifications
  • DOB/utility correspondence and accepted sign-offs

Pending in source: what to verify before acting

The November 10 extract lists the hearing as PENDING. Confirm its present scheduling, appearance method, adjournment/settlement rules and evidence deadlines directly with OATH.

Need a summons-specific action plan? For 039124824K, Building Violation LLC can scope mechanical/plumbing violation research and licensed-trade correction coordination after reviewing the actual notice and current DOB/OATH record.

Request help with boiler / gas / plumbing compliance at 2226 1 Avenue, Manhattan, NY 10029
Focused NYC DOB and OATH resolution services

Resolve the actual issue at 2226 1 Avenue, Manhattan, NY 10029 — not just the summons number

For this property, start with boiler / gas / plumbing compliance. Building Violation LLC can assess an authorized paid scope for OATH hearing preparation/representation, source-record research and correction coordination appropriate to the individual allegations. A hearing defense and a DOB compliance closeout may both be necessary.

  • Boiler / gas / plumbing compliance (2 source summonses): Mechanical/plumbing violation research and licensed-trade correction coordination.

What to send for an assessment: Bring the original summonses, current OATH notices, available DOB records and photos tied to the alleged condition. The source-listed hearing date: December 17, 2026.

Services may require separate licensed-trade, architect/engineer or attorney involvement. No outcome, penalty reduction, permit or agency approval is guaranteed; professional fees and scope are confirmed before work.

Official NYC verification resources

Verify the current OATH / DOB record

This is a point-in-time source extract, not a live court calendar. Confirm the date, appearance method, hearing status, penalties and correction requirements directly with the government before taking action.