The November 10, 2026 verified-property dataset associates 2 DOB/ECB/OATH summonses with 261 East 202 Street, Bronx, NY 10458 and source-listed date December 4, 2026. Recorded concerns include electrical safety / service equipment. Below are the exact source identifiers and allegations, followed by issue-specific defense checks, correction options and evidence needed for a responsible review.
Electrical safety / service equipment
Verified premises, hearing and enforcement snapshot
Verified premises address
261 East 202 Street, Bronx, NY 10458
Borough
Bronx
BIN
2017263
BBL
2033080092
Source summonses
2
Hearing dates in source
December 4, 2026
Source snapshot
November 10, 2026
Address verification method
PAD exact BIN
Official PAD aliases and building ranges: 261 EAST 202 STREET
Source and authorship: Building Violation LLC prepared this independent property-record explanation using a November 10, 2026 DOB/OATH source extract and verified BIN/BBL property matching. The issue analysis is editorial guidance generated from source allegations and cited laws, not a new inspection or legal determination. The source sometimes abbreviates inspector text. This is not a live OATH calendar; verify dates, appearance instructions, dispositions, monetary fields and compliance directly with NYC.
What is the December 2026 OATH hearing for at 261 East 202 Street, Bronx, NY 10458?
The uploaded record lists 2 summonses, including 039204983H (electrical safety / service equipment), 039204984J (electrical safety / service equipment). The source-listed hearing date: December 4, 2026. These are allegations and dated extract fields; the current official notices determine the actual appearance obligation and disposition.
What should the owner or respondent do first?
Verify the status of each normalized summons with OATH, obtain the complete inspector narrative and cited order/permit records, address immediate hazards, and assemble dated evidence matched to each allegation. A Certificate of Correction or other DOB closeout may remain necessary even after an OATH hearing or payment.
How the 2 recorded summonses relate at 261 East 202 Street, Bronx, NY 10458
The verified property matching links 2 distinct summonses to 261 East 202 Street, Bronx, NY 10458. They may share a property and documents, but the dataset does not establish that they arose from one inspection, one condition or one respondent. Review each summons independently.
Electrical safety / service equipment (2): source summons 039204983H, 039204984J. These charges may share a single technical investigation or corrected condition only if the actual cited locations and inspection facts match.
Shared source issue date: 2 summonses list September 22, 2026 as their issue date. Compare inspection times, sites and inspector observations before deciding whether they are factually connected.
Coordination checklist: build one property evidence folder with a separate subfolder, hearing/disposition verification and correction tracking sheet for each normalized summons number. Share drawings or photos across tickets only when the same physical facts are documented.
Each violation: allegation, defense issues, correction strategy and supporting documents
Source wording is distinguished from potential actions. These are investigatory prompts, not legal advice, guaranteed defenses or promises of DOB acceptance.
Summons 1 of the source-linked property
Electrical safety / service equipment — ECB/OATH summons 39204983H
DOB cites the condition, clearance, maintenance or safety of electrical service equipment or wiring. Key locations/components named in the source: elevator or lift.
Inspector narrative as preserved in source data
1) THE CAT-1 TAG IS EXPIRED (8.11.1.6). 2) THE ELEVATOR RAIL ARE RUSTY (COULD EFFECT THE OPERATION OF THE CAR SAFETY)(8.11.2.1.3). 3) THE PIT IS DIRTY (8.11.2.1.4). 4) THE PHONE IS NOT WORKING (8.11.2.1.1).
This is the narrative supplied in the dataset; verify it against the actual signed summons and inspector attachments.
Recorded infraction numbers and cited legal provisions:
251 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER:SERVICE EQUIPMEN
Issue date
September 22, 2026
Service date
September 22, 2026
Source severity
CLASS - 2
Source violation type
Elevators
Hearing status in extract
PENDING
DOB/ECB status in extract
ACTIVE
Correction certification in extract
Not recorded
Penalty field in extract
$625.00
Balance field in extract
$625.00
Penalty and balance are fields in the supplied November 10 extract—not independently verified current fines, final adjudications or amounts presently owed.
Record-specific resolution analysis — not an OATH finding
What the alleged violation means at 261 East 202 Street, Bronx, NY 10458
Identify whether the allegation concerns a switchboard, meter room, panel, wiring, exposed energized equipment or electrical service and distinguish a safety deficiency from unpermitted new work. Key locations/components named in the source: elevator or lift. Record-specific inspection detail: Inspector text begins: “1) THE CAT-1 TAG IS EXPIRED (8.11.1.6). 2) THE ELEVATOR RAIL ARE RUSTY (COULD EFFECT THE OPERATION OF THE CAR SAFETY)(8.11.2.1.3). 3) THE PIT IS DIRTY (8.1…”
Possible defense questions and factual disputes to investigate
The following are issues to verify, not assurances that a defense applies to summons 039204983H.
Whether the cited component, clearance or unsafe condition existed as described
Whether the equipment met the applicable requirements and was inspected/maintained
Whether the notice identified the correct location and owner responsibility
Compare the original summons, issue/service dates and the complete inspector narrative with each document; do not assume any potential defense is established without proof.
Correction and DOB closeout strategy
Secure unsafe equipment or exposed wiring with a licensed electrician promptly.
Repair or replace components as needed and document proper inspection, electrical filings and compliance closeout.
Determine whether DOB requires a Certificate of Correction, a separate reinspection, application/permit sign-off or an order-lift. An OATH outcome, a paid fine and physical correction are separate issues.
Evidence and documents tailored to this allegation
device inspection and service documentation
electrical service and panel photographs with location
licensed electrician safety evaluation and invoices
electrical permits, inspections and test reports
equipment specification or maintenance and repair records
Pending in source: what to verify before acting
The November 10 extract lists the hearing as PENDING. Confirm its present scheduling, appearance method, adjournment/settlement rules and evidence deadlines directly with OATH.
Need a summons-specific action plan? For 039204983H, Building Violation LLC can scope electrical maintenance summons analysis and licensed-trade remediation after reviewing the actual notice and current DOB/OATH record.
DOB cites the condition, clearance, maintenance or safety of electrical service equipment or wiring. Key locations/components named in the source: elevator or lift.
Inspector narrative as preserved in source data
1) THE CAT-1 TAG IS EXPIRED (8.11.1.6). 2) THE ELEVATOR RAIL ARE RUSTY (COULD EFFECT THE OPERATION OF THE CAR SAFETY)(8.11.2.1.3). 3) THE PIT IS DIRTY (8.11.2.1.4). 4) THE PHONE IS NOT WORKING (8.11.2.1.1).
This is the narrative supplied in the dataset; verify it against the actual signed summons and inspector attachments.
Recorded infraction numbers and cited legal provisions:
251 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER:SERVICE EQUIPMEN
Issue date
September 22, 2026
Service date
September 22, 2026
Source severity
CLASS - 2
Source violation type
Elevators
Hearing status in extract
PENDING
DOB/ECB status in extract
ACTIVE
Correction certification in extract
Not recorded
Penalty field in extract
$625.00
Balance field in extract
$625.00
Penalty and balance are fields in the supplied November 10 extract—not independently verified current fines, final adjudications or amounts presently owed.
Record-specific resolution analysis — not an OATH finding
What the alleged violation means at 261 East 202 Street, Bronx, NY 10458
Identify whether the allegation concerns a switchboard, meter room, panel, wiring, exposed energized equipment or electrical service and distinguish a safety deficiency from unpermitted new work. Key locations/components named in the source: elevator or lift. Record-specific inspection detail: Inspector text begins: “1) THE CAT-1 TAG IS EXPIRED (8.11.1.6). 2) THE ELEVATOR RAIL ARE RUSTY (COULD EFFECT THE OPERATION OF THE CAR SAFETY)(8.11.2.1.3). 3) THE PIT IS DIRTY (8.1…”
Possible defense questions and factual disputes to investigate
The following are issues to verify, not assurances that a defense applies to summons 039204984J.
Whether the cited component, clearance or unsafe condition existed as described
Whether the equipment met the applicable requirements and was inspected/maintained
Whether the notice identified the correct location and owner responsibility
Compare the original summons, issue/service dates and the complete inspector narrative with each document; do not assume any potential defense is established without proof.
Correction and DOB closeout strategy
Secure unsafe equipment or exposed wiring with a licensed electrician promptly.
Repair or replace components as needed and document proper inspection, electrical filings and compliance closeout.
Determine whether DOB requires a Certificate of Correction, a separate reinspection, application/permit sign-off or an order-lift. An OATH outcome, a paid fine and physical correction are separate issues.
Evidence and documents tailored to this allegation
device inspection and service documentation
electrical service and panel photographs with location
licensed electrician safety evaluation and invoices
electrical permits, inspections and test reports
equipment specification or maintenance and repair records
Pending in source: what to verify before acting
The November 10 extract lists the hearing as PENDING. Confirm its present scheduling, appearance method, adjournment/settlement rules and evidence deadlines directly with OATH.
Need a summons-specific action plan? For 039204984J, Building Violation LLC can scope electrical maintenance summons analysis and licensed-trade remediation after reviewing the actual notice and current DOB/OATH record.
Resolve the actual issue at 261 East 202 Street, Bronx, NY 10458 — not just the summons number
For this property, start with electrical safety / service equipment. Building Violation LLC can assess an authorized paid scope for OATH hearing preparation/representation, source-record research and correction coordination appropriate to the individual allegations. A hearing defense and a DOB compliance closeout may both be necessary.
Electrical safety / service equipment (2 source summonses): Electrical maintenance summons analysis and licensed-trade remediation.
What to send for an assessment: Bring the original summonses, current OATH notices, available DOB records and photos tied to the alleged condition. The source-listed hearing date: December 4, 2026.
Services may require separate licensed-trade, architect/engineer or attorney involvement. No outcome, penalty reduction, permit or agency approval is guaranteed; professional fees and scope are confirmed before work.
This is a point-in-time source extract, not a live court calendar. Confirm the date, appearance method, hearing status, penalties and correction requirements directly with the government before taking action.
Important: This private-service page is not affiliated with NYC OATH or DOB, does not establish guilt or innocence and is not legal advice. Building Violation LLC may provide authorized non-attorney OATH representation and violation-resolution coordination within its permitted scope. Different proceedings can require an attorney or licensed professional. The source field named PENALITY_IMPOSED is shown for transparency but does not prove a presently payable adjudicated amount.