Fire alarm / sprinkler / suppression — ECB/OATH summons 39208254X
Normalized ten-character lookup: 039208254X (infraction 202)
Source allegation and actual cited law
The record alleges a deficiency in fire detection, alarm, sprinkler or suppression equipment. Key locations/components named in the source: fire-protection system.
Inspector narrative as preserved in source data — potentially incomplete
AT THE TIME OF INSPECTION OBSERVED SPRINKLER HEADS OBSERVED ON THE 4TH FLOORS IN THE BATHROOMS OBSTRUCTED BY LIGHTS AND DROP CEILING. BC 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER SYSTEMS. IT MAND
The supplied record stops at its extract limit and may omit the rest of the inspector narrative. Obtain the complete original summons before making a factual or legal decision.
- 202 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER
- Issue date
- October 16, 2026
- Service date
- October 16, 2026
- Source severity
- CLASS - 2
- Source violation type
- Construction
- Hearing status in extract
- PENDING
- DOB/ECB status in extract
- ACTIVE
- Correction certification in extract
- Not recorded
- Penalty field in extract
- $1,250.00
- Balance field in extract
- $1,250.00
Penalty and balance are fields in the supplied November 10 extract—not independently verified current fines, final adjudications or amounts presently owed.
What the alleged violation means at 275 37 Street, Brooklyn, NY 11232
Identify which system, floor or occupancy is cited; check whether it was required and what installation, maintenance, testing or sign-off was missing at inspection. Key locations/components named in the source: fire-protection system. Record-specific inspection detail: Inspector text begins: “AT THE TIME OF INSPECTION OBSERVED SPRINKLER HEADS OBSERVED ON THE 4TH FLOORS IN THE BATHROOMS OBSTRUCTED BY LIGHTS AND DROP CEILING. BC 903.3.3 OBSTRUCTED…”
Possible defense questions and factual disputes to investigate
The following are issues to verify, not assurances that a defense applies to summons 039208254X.
- Whether the listed system was legally required for the approved use and occupancy
- Whether accepted fire-protection plans, test reports or system inspections cover the issue
- Whether the inspector described the correct system, equipment and location
- Compare the original summons, issue/service dates and the complete inspector narrative with each document; do not assume any potential defense is established without proof.
Correction and DOB closeout strategy
- Treat functional fire-safety defects as urgent and obtain qualified inspection.
- Coordinate any needed FDNY/DOB permits, licensed fire-safety contractor corrections, tests and acceptance paperwork.
Determine whether DOB requires a Certificate of Correction, a separate reinspection, application/permit sign-off or an order-lift. An OATH outcome, a paid fine and physical correction are separate issues.
Evidence and documents tailored to this allegation
- fire-system test certificates and approved system drawings
- approved fire-protection/alarm plans and permits
- system inspection, service and acceptance test reports
- contractor invoices and before/after dated equipment photos
- FDNY or DOB notices and agency sign-offs
Pending in source: what to verify before acting
The November 10 extract lists the hearing as PENDING. Confirm its present scheduling, appearance method, adjournment/settlement rules and evidence deadlines directly with OATH.