34-25 109 Street, Queens, NY 11368 — Work contrary to approved plans and December 2026 OATH Hearing Details
The November 10, 2026 verified-property dataset associates 4 DOB/ECB/OATH summonses with 34-25 109 Street, Queens, NY 11368 and source-listed dates December 1, 2026, December 29, 2026. Recorded concerns include work contrary to approved plans, roadway / sidewalk work-zone permits, temporary platforms / construction access safety and other allegations. Below are the exact source identifiers and allegations, followed by issue-specific defense checks, correction options and evidence needed for a responsible review.
Work contrary to approved plansRoadway / sidewalk work-zone permitsTemporary platforms / construction access safetySite safety / construction operations
Verified premises, hearing and enforcement snapshot
Verified premises address
34-25 109 Street, Queens, NY 11368
Borough
Queens
BIN
4043688
BBL
4017530112
Source summonses
4
Hearing dates in source
December 1, 2026, December 29, 2026
Source snapshot
November 10, 2026
Address verification method
OATH normalized summons
Source and authorship: Building Violation LLC prepared this independent property-record explanation using a November 10, 2026 DOB/OATH source extract and verified BIN/BBL property matching. The issue analysis is editorial guidance generated from source allegations and cited laws, not a new inspection or legal determination. The source sometimes abbreviates inspector text. This is not a live OATH calendar; verify dates, appearance instructions, dispositions, monetary fields and compliance directly with NYC.
What merits immediate verification: one or more Class 1 source allegations; one or more possibly shortened inspector narratives. Read the current OATH and DOB records before acting.
What is the December 2026 OATH hearing for at 34-25 109 Street, Queens, NY 11368?
The uploaded record lists 4 summonses, including 039557482N (work contrary to approved plans), 039557484R (roadway / sidewalk work-zone permits), 039560821X (temporary platforms / construction access safety), 039560820Y (site safety / construction operations). The source-listed hearing dates: December 1, 2026, December 29, 2026. These are allegations and dated extract fields; the current official notices determine the actual appearance obligation and disposition.
What should the owner or respondent do first?
Verify the status of each normalized summons with OATH, obtain the complete inspector narrative and cited order/permit records, address immediate hazards, and assemble dated evidence matched to each allegation. A Certificate of Correction or other DOB closeout may remain necessary even after an OATH hearing or payment.
How the 4 recorded summonses relate at 34-25 109 Street, Queens, NY 11368
The verified property matching links 4 distinct summonses to 34-25 109 Street, Queens, NY 11368. They may share a property and documents, but the dataset does not establish that they arose from one inspection, one condition or one respondent. Review each summons independently.
Roadway / sidewalk work-zone permits (1): source summons 039557484R. Check this charge separately, even when its documents can be gathered with other property records.
Site safety / construction operations (1): source summons 039560820Y. Check this charge separately, even when its documents can be gathered with other property records.
Temporary platforms / construction access safety (1): source summons 039560821X. Check this charge separately, even when its documents can be gathered with other property records.
Work contrary to approved plans (1): source summons 039557482N. Check this charge separately, even when its documents can be gathered with other property records.
Shared source issue date: 2 summonses list August 4, 2026 as their issue date. Compare inspection times, sites and inspector observations before deciding whether they are factually connected.
Shared source issue date: 2 summonses list October 20, 2026 as their issue date. Compare inspection times, sites and inspector observations before deciding whether they are factually connected.
More than one source-listed hearing date: December 1, 2026, December 29, 2026. Do not treat one appearance or adjournment as disposing of every summons; confirm each date separately.
Coordination checklist: build one property evidence folder with a separate subfolder, hearing/disposition verification and correction tracking sheet for each normalized summons number. Share drawings or photos across tickets only when the same physical facts are documented.
Each violation: allegation, defense issues, correction strategy and supporting documents
Source wording is distinguished from potential actions. These are investigatory prompts, not legal advice, guaranteed defenses or promises of DOB acceptance.
Summons 1 of the source-linked property
Work contrary to approved plans — ECB/OATH summons 39557482N
The record alleges work that differs from DOB-approved documents or amendments. Key locations/components named in the source: structural framing, exterior masonry.
Inspector narrative as preserved in source data — potentially incomplete
OBSERVED CANTILEVER BALCONIES AT THE FACADE EXP#1 UPON REVIEWING THE STRUCTURAL AND ARCHITECTURAL APPROVED PLANS IT SHOWS NO BALCONIES AT THE FACADE. CREATING SAFETY AND COLLAPSE HAZARDS CAUSE I'M UNABLE TO VER
The supplied record stops at its extract limit and may omit the rest of the inspector narrative. Obtain the complete original summons before making a factual or legal decision.
Recorded infraction numbers and cited legal provisions:
282 — 28-105.12.2 WRK DOESN'T CONFORM TO APPROV DOCS AND/OR APPROV AMENDMENTS
Issue date
August 4, 2026
Service date
August 4, 2026
Source severity
CLASS - 2
Source violation type
Construction
Hearing status in extract
PENDING
DOB/ECB status in extract
ACTIVE
Correction certification in extract
Not recorded
Penalty field in extract
$1,250.00
Balance field in extract
$1,250.00
Penalty and balance are fields in the supplied November 10 extract—not independently verified current fines, final adjudications or amounts presently owed.
Record-specific resolution analysis — not an OATH finding
What the alleged violation means at 34-25 109 Street, Queens, NY 11368
Identify the application number, approval set, revision history and exactly which constructed conditions the inspector says differ. Key locations/components named in the source: structural framing, exterior masonry. Record-specific inspection detail: Inspector text begins: “OBSERVED CANTILEVER BALCONIES AT THE FACADE EXP#1 UPON REVIEWING THE STRUCTURAL AND ARCHITECTURAL APPROVED PLANS IT SHOWS NO BALCONIES AT THE FACADE. CREAT…”
Possible defense questions and factual disputes to investigate
The following are issues to verify, not assurances that a defense applies to summons 039557482N.
Whether the cited plans were the operative approved set on the inspection date
Whether an approved amendment, phased work or as-built record covers the observed condition
Whether the alleged difference is accurately described and located
Compare the original summons, issue/service dates and the complete inspector narrative with each document; do not assume any potential defense is established without proof.
Correction and DOB closeout strategy
Compare field conditions with approved documents through a registered design professional.
Where necessary, amend plans, correct nonconforming work and arrange required permits/inspections before DOB closeout.
Determine whether DOB requires a Certificate of Correction, a separate reinspection, application/permit sign-off or an order-lift. An OATH outcome, a paid fine and physical correction are separate issues.
Evidence and documents tailored to this allegation
approved framing plans and structural engineer assessment
photographs by elevation and facade professional repair reports
approved plans, amendments and application history
current as-built measurements or professional field report
dated construction photographs and contractor records
inspection and sign-off documents
Pending in source: what to verify before acting
The November 10 extract lists the hearing as PENDING. Confirm its present scheduling, appearance method, adjournment/settlement rules and evidence deadlines directly with OATH.
Need a summons-specific action plan? For 039557482N, Building Violation LLC can scope approved-plan discrepancy review and amendment/permit coordination after reviewing the actual notice and current DOB/OATH record.
The inspector identifies work-zone equipment, barriers, containers or temporary occupancy of a street or sidewalk, possibly with a missing or expired DOT permit. The exact cited location/component should be confirmed against the original inspection record.
Inspector narrative as preserved in source data — potentially incomplete
OBSERVED PUBLIC SIDEWALK AT EXP#1 WITH CRACKS AND DEBRIS FROM BROKEN CONCRETE WITHOUT ANY PROTECTION OR TEMPORARY CLEAR WALKWAY AS REQUIRED BY 3307.2 AND DOT. OBSTRUCTING WALKWAY AND ENDANGERING THE PUBLIC BY C
The supplied record stops at its extract limit and may omit the rest of the inspector narrative. Obtain the complete original summons before making a factual or legal decision.
Recorded infraction numbers and cited legal provisions:
2N8
Issue date
August 4, 2026
Service date
August 4, 2026
Source severity
CLASS - 2
Source violation type
Unknown
Hearing status in extract
PENDING
DOB/ECB status in extract
ACTIVE
Correction certification in extract
Not recorded
Penalty field in extract
$625.00
Balance field in extract
$625.00
Penalty and balance are fields in the supplied November 10 extract—not independently verified current fines, final adjudications or amounts presently owed.
Record-specific resolution analysis — not an OATH finding
What the alleged violation means at 34-25 109 Street, Queens, NY 11368
Determine the exact street/sidewalk location, work-zone equipment, DOT occupancy permit dates and whether pedestrian protection was sufficient. The exact cited location/component should be confirmed against the original inspection record. Record-specific inspection detail: Inspector text begins: “OBSERVED PUBLIC SIDEWALK AT EXP#1 WITH CRACKS AND DEBRIS FROM BROKEN CONCRETE WITHOUT ANY PROTECTION OR TEMPORARY CLEAR WALKWAY AS REQUIRED BY 3307.2 AND D…”
Possible defense questions and factual disputes to investigate
The following are issues to verify, not assurances that a defense applies to summons 039557484R.
Whether a valid permit covered the correct roadway segment, dates and equipment
Whether a temporary encroachment or pedestrian obstruction occurred as described
Whether contemporaneous permits, inspection logs or removal records contradict the allegation
Compare the original summons, issue/service dates and the complete inspector narrative with each document; do not assume any potential defense is established without proof.
Correction and DOB closeout strategy
Correct unsafe sidewalk/roadway obstructions and secure the applicable permit or remove equipment where appropriate.
Coordinate contractor and DOT documentation, photographs and any DOB compliance response for the specific site condition.
Determine whether DOB requires a Certificate of Correction, a separate reinspection, application/permit sign-off or an order-lift. An OATH outcome, a paid fine and physical correction are separate issues.
Evidence and documents tailored to this allegation
NYC DOT permits and permit effective dates
dated street/sidewalk photos and work-zone layout
barrier, dumpster or equipment placement and removal logs
contractor site-safety inspection and access records
Pending in source: what to verify before acting
The November 10 extract lists the hearing as PENDING. Confirm its present scheduling, appearance method, adjournment/settlement rules and evidence deadlines directly with OATH.
Need a summons-specific action plan? For 039557484R, Building Violation LLC can scope roadway/sidewalk work-zone summons analysis and permit coordination after reviewing the actual notice and current DOB/OATH record.
The inspector alleges an unsafe or unapproved temporary platform, access arrangement or construction support. Key locations/components named in the source: stairs or landings.
Inspector narrative as preserved in source data — potentially incomplete
BC3301.7 TEMP PLATFORM: DURING INSPECTION OF A 3 STORY BUILDING I OBSERVED BETWEEN THE 2ND AND 3RD STORY IN THE STAIRCASE A WOODEN MAKESHIFT PLATFORM, MADE OUT OF 2X4 AND PLANKS COVERING THE LANDING. A TEMPORAR
The supplied record stops at its extract limit and may omit the rest of the inspector narrative. Obtain the complete original summons before making a factual or legal decision.
Recorded infraction numbers and cited legal provisions:
2P7
Issue date
October 20, 2026
Service date
October 20, 2026
Source severity
CLASS - 2
Source violation type
Unknown
Hearing status in extract
PENDING
DOB/ECB status in extract
ACTIVE
Correction certification in extract
Not recorded
Penalty field in extract
$2,500.00
Balance field in extract
$2,500.00
Penalty and balance are fields in the supplied November 10 extract—not independently verified current fines, final adjudications or amounts presently owed.
Record-specific resolution analysis — not an OATH finding
What the alleged violation means at 34-25 109 Street, Queens, NY 11368
Identify the platform, elevation, design, loading and affected worker or exit route referred to in the inspection narrative. Key locations/components named in the source: stairs or landings. Record-specific inspection detail: Inspector text begins: “BC3301.7 TEMP PLATFORM: DURING INSPECTION OF A 3 STORY BUILDING I OBSERVED BETWEEN THE 2ND AND 3RD STORY IN THE STAIRCASE A WOODEN MAKESHIFT PLATFORM, MADE…”
Possible defense questions and factual disputes to investigate
The following are issues to verify, not assurances that a defense applies to summons 039560821X.
Whether the temporary platform was installed and used as alleged
Whether an approved engineered platform or site-safety plan covered the arrangement
Whether contemporaneous photos, access records or inspections clarify the claimed risk
Compare the original summons, issue/service dates and the complete inspector narrative with each document; do not assume any potential defense is established without proof.
Correction and DOB closeout strategy
Stop unsafe platform use and have a qualified site-safety professional review access and structural support.
Replace or remove inadequate temporary works and obtain appropriate plans, permits and inspection documentation where required.
Determine whether DOB requires a Certificate of Correction, a separate reinspection, application/permit sign-off or an order-lift. An OATH outcome, a paid fine and physical correction are separate issues.
Evidence and documents tailored to this allegation
stair/landing measurements and dated photos or approved egress plans
engineered platform or temporary works details
site safety plan and equipment inspection logs
dated photographs of framing, access and load arrangements
contractor corrective-work records and agency correspondence
Pending in source: what to verify before acting
The November 10 extract lists the hearing as PENDING. Confirm its present scheduling, appearance method, adjournment/settlement rules and evidence deadlines directly with OATH.
Need a summons-specific action plan? For 039560821X, Building Violation LLC can scope temporary-platform safety and hearing-evidence coordination after reviewing the actual notice and current DOB/OATH record.
The cited item concerns safety practices, documentation, supervision or housekeeping at a construction site. Key locations/components named in the source: stairs or landings.
Inspector narrative as preserved in source data — potentially incomplete
INSPECTION OF AN ACTIVE 3 STORY BUILDING, I OBSERVED IN THE STAIRCASE THAT THERE WAS NO HANDRAILS INSTALLED AT ALL 3 STORIES. THE LACK OF HANDRAILS CREATES A HAZARD FOR ANYONE WALKING UP AND DOWN THE STAIRS, TO
The supplied record stops at its extract limit and may omit the rest of the inspector narrative. Obtain the complete original summons before making a factual or legal decision.
Recorded infraction numbers and cited legal provisions:
120 — BC 3301.2,27-1009(A) FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY
Issue date
October 20, 2026
Service date
October 20, 2026
Source severity
CLASS - 1
Source violation type
Construction
Hearing status in extract
PENDING
DOB/ECB status in extract
ACTIVE
Correction certification in extract
Not recorded
Penalty field in extract
$2,500.00
Balance field in extract
$2,500.00
Penalty and balance are fields in the supplied November 10 extract—not independently verified current fines, final adjudications or amounts presently owed.
Safety priority: Class 1 in source — treat any alleged immediately hazardous condition as urgent; verify specific DOB correction requirements.
Record-specific resolution analysis — not an OATH finding
What the alleged violation means at 34-25 109 Street, Queens, NY 11368
Identify the exact construction operation, site location, plan, log, posting, supervision or housekeeping requirement the inspector lists. Key locations/components named in the source: stairs or landings. Record-specific inspection detail: Inspector text begins: “INSPECTION OF AN ACTIVE 3 STORY BUILDING, I OBSERVED IN THE STAIRCASE THAT THERE WAS NO HANDRAILS INSTALLED AT ALL 3 STORIES. THE LACK OF HANDRAILS CREATES…”
Possible defense questions and factual disputes to investigate
The following are issues to verify, not assurances that a defense applies to summons 039560820Y.
Whether construction was underway and the cited safety duty applied at the relevant time
Whether required postings, logs, plans or supervision were in place
Whether the cited conditions or documents belonged to this job site and respondent
Compare the original summons, issue/service dates and the complete inspector narrative with each document; do not assume any potential defense is established without proof.
Correction and DOB closeout strategy
Correct active site hazards immediately and involve the qualified site safety/contractor team.
Update required plans, safety controls, postings, inspections or records and document remediation.
Determine whether DOB requires a Certificate of Correction, a separate reinspection, application/permit sign-off or an order-lift. An OATH outcome, a paid fine and physical correction are separate issues.
Evidence and documents tailored to this allegation
stair/landing measurements and dated photos or approved egress plans
site safety plan, permits and approved construction documents
daily inspection logs, toolbox talks and supervisory assignments
dated job-site photos with exposure or floor
contractor correction records and agency inspection reports
Pending in source: what to verify before acting
The November 10 extract lists the hearing as PENDING. Confirm its present scheduling, appearance method, adjournment/settlement rules and evidence deadlines directly with OATH.
Need a summons-specific action plan? For 039560820Y, Building Violation LLC can scope construction safety hearing preparation and contractor/site-safety coordination after reviewing the actual notice and current DOB/OATH record.
Resolve the actual issue at 34-25 109 Street, Queens, NY 11368 — not just the summons number
For this property, start with work contrary to approved plans and 3 additional issue categories. Building Violation LLC can assess an authorized paid scope for OATH hearing preparation/representation, source-record research and correction coordination appropriate to the individual allegations. A hearing defense and a DOB compliance closeout may both be necessary.
Work contrary to approved plans (1 source summons): Approved-plan discrepancy review and amendment/permit coordination.
Temporary platforms / construction access safety (1 source summons): Temporary-platform safety and hearing-evidence coordination.
What to send for an assessment: Bring the original summonses, current OATH notices, available DOB records and photos tied to the alleged condition. The source-listed hearing dates: December 1, 2026, December 29, 2026.
Services may require separate licensed-trade, architect/engineer or attorney involvement. No outcome, penalty reduction, permit or agency approval is guaranteed; professional fees and scope are confirmed before work.
This is a point-in-time source extract, not a live court calendar. Confirm the date, appearance method, hearing status, penalties and correction requirements directly with the government before taking action.
Important: This private-service page is not affiliated with NYC OATH or DOB, does not establish guilt or innocence and is not legal advice. Building Violation LLC may provide authorized non-attorney OATH representation and violation-resolution coordination within its permitted scope. Different proceedings can require an attorney or licensed professional. The source field named PENALITY_IMPOSED is shown for transparency but does not prove a presently payable adjudicated amount.