Mechanical ventilation / exhaust / flue — ECB/OATH summons 39201717L
Normalized ten-character lookup: 039201717L (infraction 280)
Source allegation and actual cited law
DOB alleges a ventilation, kitchen-exhaust, chimney, fireplace, smoke or mechanical-system condition. Key locations/components named in the source: roof or rooftop.
Inspector narrative as preserved in source data
FOUND 20 OUT OF 30 EXHAUST UNITS LOCATED ON ROOF NOT OPERABLE.; MISC, COMPLY WITH NOTICE OF VIOLATION; REPAIR OR REPLACE EXHAUST UNITS.
This is the narrative supplied in the dataset; verify it against the actual signed summons and inspector attachments.
- 280 — PC MISCFGC-MISCMC-MIS MISCELLANEOUS VIOLATIONS
- Issue date
- August 25, 2026
- Service date
- August 25, 2026
- Source severity
- CLASS - 2
- Source violation type
- Plumbing
- Hearing status in extract
- PENDING
- DOB/ECB status in extract
- ACTIVE
- Correction certification in extract
- Not recorded
- Penalty field in extract
- $1,250.00
- Balance field in extract
- $1,250.00
Penalty and balance are fields in the supplied November 10 extract—not independently verified current fines, final adjudications or amounts presently owed.
What the alleged violation means at 385 East 184 Street, Bronx, NY 10458
Identify the affected exhaust unit, room, flue or fireplace and compare the alleged condition with mechanical plans, inspections and actual airflow or equipment operation. Key locations/components named in the source: roof or rooftop. Record-specific inspection detail: Inspector text begins: “FOUND 20 OUT OF 30 EXHAUST UNITS LOCATED ON ROOF NOT OPERABLE.; MISC, COMPLY WITH NOTICE OF VIOLATION; REPAIR OR REPLACE EXHAUST UNITS.”
Possible defense questions and factual disputes to investigate
The following are issues to verify, not assurances that a defense applies to summons 039201717L.
- Whether the source correctly identifies the mechanical equipment and condition
- Whether approved mechanical filings, test results or contemporaneous maintenance prove the alleged issue was already addressed
- Whether the cited smoke migration, ventilation or clearance condition occurred as described
- Compare the original summons, issue/service dates and the complete inspector narrative with each document; do not assume any potential defense is established without proof.
Correction and DOB closeout strategy
- Investigate smoke, combustion or ventilation hazards promptly with the appropriate licensed contractor.
- Repair or balance affected equipment, conduct required smoke/airflow tests and obtain applicable filings, inspections and acceptance documents.
Determine whether DOB requires a Certificate of Correction, a separate reinspection, application/permit sign-off or an order-lift. An OATH outcome, a paid fine and physical correction are separate issues.
Evidence and documents tailored to this allegation
- dated roof photographs and any roofing/equipment permit documents
- approved mechanical plans, equipment schedules or flue drawings
- licensed contractor airflow/smoke test reports and invoices
- maintenance logs and dated equipment photographs
- DOB/FDNY notices, inspection results and correction records
Pending in source: what to verify before acting
The November 10 extract lists the hearing as PENDING. Confirm its present scheduling, appearance method, adjournment/settlement rules and evidence deadlines directly with OATH.
Need a summons-specific action plan? For 039201717L, Building Violation LLC can scope mechanical-ventilation and exhaust code-compliance coordination after reviewing the actual notice and current DOB/OATH record.
Request help with mechanical ventilation / exhaust / flue at 385 East 184 Street, Bronx, NY 10458