NYC DOB / ECB / OATH hearings · verified property resolution

755 Oakland Place, Bronx, NY 10457 — Fire alarm / sprinkler / suppression and December 2026 OATH Hearing Details

The November 10, 2026 verified-property dataset associates 2 DOB/ECB/OATH summonses with 755 Oakland Place, Bronx, NY 10457 and source-listed date December 18, 2026. Recorded concerns include fire alarm / sprinkler / suppression, unsafe condition / maintenance. Below are the exact source identifiers and allegations, followed by issue-specific defense checks, correction options and evidence needed for a responsible review.

Fire alarm / sprinkler / suppressionUnsafe condition / maintenance

Verified premises, hearing and enforcement snapshot

Verified premises address
755 Oakland Place, Bronx, NY 10457
Borough
Bronx
BIN
2012653
BBL
2030940054
Source summonses
2
Hearing dates in source
December 18, 2026
Source snapshot
November 10, 2026
Address verification method
PAD exact BIN

Official PAD aliases and building ranges: 2063 PROSPECT AVENUE; 755 through 757 OAKLAND PLACE

Premises precision: Official building range; low endpoint shown; multiple aliases. A verified building-level match does not prove an exact apartment or entrance.

Source and authorship: Building Violation LLC prepared this independent property-record explanation using a November 10, 2026 DOB/OATH source extract and verified BIN/BBL property matching. The issue analysis is editorial guidance generated from source allegations and cited laws, not a new inspection or legal determination. The source sometimes abbreviates inspector text. This is not a live OATH calendar; verify dates, appearance instructions, dispositions, monetary fields and compliance directly with NYC.

What merits immediate verification: one or more possibly shortened inspector narratives. Read the current OATH and DOB records before acting.

What is the December 2026 OATH hearing for at 755 Oakland Place, Bronx, NY 10457?

The uploaded record lists 2 summonses, including 039206442Y (fire alarm / sprinkler / suppression), 039206441M (unsafe condition / maintenance). The source-listed hearing date: December 18, 2026. These are allegations and dated extract fields; the current official notices determine the actual appearance obligation and disposition.

What should the owner or respondent do first?

Verify the status of each normalized summons with OATH, obtain the complete inspector narrative and cited order/permit records, address immediate hazards, and assemble dated evidence matched to each allegation. A Certificate of Correction or other DOB closeout may remain necessary even after an OATH hearing or payment.

December 2026 summonses and listed hearing times

Summons / lookupSource hearing date / timeSeverityRecorded subjectSource disposition
39206442Y
039206442Y
8:30 AM
CLASS - 2Fire alarm / sprinkler / suppressionPENDING
39206441M
039206441M
10:30 AM
CLASS - 2Unsafe condition / maintenancePENDING

How the 2 recorded summonses relate at 755 Oakland Place, Bronx, NY 10457

The verified property matching links 2 distinct summonses to 755 Oakland Place, Bronx, NY 10457. They may share a property and documents, but the dataset does not establish that they arose from one inspection, one condition or one respondent. Review each summons independently.

Fire alarm / sprinkler / suppression (1): source summons 039206442Y. Check this charge separately, even when its documents can be gathered with other property records.

Unsafe condition / maintenance (1): source summons 039206441M. Check this charge separately, even when its documents can be gathered with other property records.

Shared source issue date: 2 summonses list October 2, 2026 as their issue date. Compare inspection times, sites and inspector observations before deciding whether they are factually connected.

Coordination checklist: build one property evidence folder with a separate subfolder, hearing/disposition verification and correction tracking sheet for each normalized summons number. Share drawings or photos across tickets only when the same physical facts are documented.

Each violation: allegation, defense issues, correction strategy and supporting documents

Source wording is distinguished from potential actions. These are investigatory prompts, not legal advice, guaranteed defenses or promises of DOB acceptance.

Summons 1 of the source-linked property

Fire alarm / sprinkler / suppression — ECB/OATH summons 39206442Y

Normalized ten-character lookup: 039206442Y (infraction 239)

November 10 source-listed hearing8:30 AM

Source allegation and actual cited law

The record alleges a deficiency in fire detection, alarm, sprinkler or suppression equipment. Key locations/components named in the source: cellar or basement area.

Inspector narrative as preserved in source data — potentially incomplete

FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3; 27-345. NOTED: AT TIME OF INSPECTION - FIRE RATED MATERIAL OBSERVED COMPROMISED AT CELLAR CEILING THROUGHOUT; CONCRETE PIERC

The supplied record stops at its extract limit and may omit the rest of the inspector narrative. Obtain the complete original summons before making a factual or legal decision.

Recorded infraction numbers and cited legal provisions:
  • 239 — 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPIN
Issue date
October 2, 2026
Service date
October 2, 2026
Source severity
CLASS - 2
Source violation type
Construction
Hearing status in extract
PENDING
DOB/ECB status in extract
ACTIVE
Correction certification in extract
Not recorded
Penalty field in extract
$1,250.00
Balance field in extract
$1,250.00

Penalty and balance are fields in the supplied November 10 extract—not independently verified current fines, final adjudications or amounts presently owed.

What the alleged violation means at 755 Oakland Place, Bronx, NY 10457

Identify which system, floor or occupancy is cited; check whether it was required and what installation, maintenance, testing or sign-off was missing at inspection. Key locations/components named in the source: cellar or basement area. Record-specific inspection detail: Inspector text begins: “FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3; 27-345. NOTED: AT TIME OF INSPECTION - FIRE RATED MATERIAL OBSERVED C…”

Possible defense questions and factual disputes to investigate

The following are issues to verify, not assurances that a defense applies to summons 039206442Y.

  • Whether the listed system was legally required for the approved use and occupancy
  • Whether accepted fire-protection plans, test reports or system inspections cover the issue
  • Whether the inspector described the correct system, equipment and location
  • Compare the original summons, issue/service dates and the complete inspector narrative with each document; do not assume any potential defense is established without proof.

Correction and DOB closeout strategy

  • Treat functional fire-safety defects as urgent and obtain qualified inspection.
  • Coordinate any needed FDNY/DOB permits, licensed fire-safety contractor corrections, tests and acceptance paperwork.

Determine whether DOB requires a Certificate of Correction, a separate reinspection, application/permit sign-off or an order-lift. An OATH outcome, a paid fine and physical correction are separate issues.

Evidence and documents tailored to this allegation

  • dated cellar/basement photos and approved basement floor plan
  • approved fire-protection/alarm plans and permits
  • system inspection, service and acceptance test reports
  • contractor invoices and before/after dated equipment photos
  • FDNY or DOB notices and agency sign-offs

Pending in source: what to verify before acting

The November 10 extract lists the hearing as PENDING. Confirm its present scheduling, appearance method, adjournment/settlement rules and evidence deadlines directly with OATH.

Need a summons-specific action plan? For 039206442Y, Building Violation LLC can scope fire-protection summons review and licensed-contractor compliance coordination after reviewing the actual notice and current DOB/OATH record.

Request help with fire alarm / sprinkler / suppression at 755 Oakland Place, Bronx, NY 10457
Summons 2 of the source-linked property

Unsafe condition / maintenance — ECB/OATH summons 39206441M

Normalized ten-character lookup: 039206441M (infraction 202)

November 10 source-listed hearing10:30 AM

Source allegation and actual cited law

DOB alleges a failure to maintain a building component in code-compliant or safe condition. Key locations/components named in the source: door or exit route, kitchen or bathroom.

Inspector narrative as preserved in source data — potentially incomplete

FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION - BTHRM FLR SINKING OBSERVED, APPRX. 4"X4" AT TOILET & 1"X3" SECTIONS AT ENTRY DOOR: WOOD FLOORING BENEATH CERAMIC TILE COSMET

The supplied record stops at its extract limit and may omit the rest of the inspector narrative. Obtain the complete original summons before making a factual or legal decision.

Recorded infraction numbers and cited legal provisions:
  • 202 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER
Issue date
October 2, 2026
Service date
October 2, 2026
Source severity
CLASS - 2
Source violation type
Construction
Hearing status in extract
PENDING
DOB/ECB status in extract
ACTIVE
Correction certification in extract
Not recorded
Penalty field in extract
$1,250.00
Balance field in extract
$1,250.00

Penalty and balance are fields in the supplied November 10 extract—not independently verified current fines, final adjudications or amounts presently owed.

What the alleged violation means at 755 Oakland Place, Bronx, NY 10457

A general maintenance law citation is not the actual defect: the condition is the specific item described in the inspector narrative, which must be examined with photographs and repair records. Key locations/components named in the source: door or exit route, kitchen or bathroom. Record-specific inspection detail: Inspector text begins: “FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION - BTHRM FLR SINKING OBSERVED, APPRX. 4"X4" AT TOILET & 1"X3" SECTIONS A…”

Possible defense questions and factual disputes to investigate

The following are issues to verify, not assurances that a defense applies to summons 039206441M.

  • Whether the exact physical condition and location existed on the inspection date
  • Whether the cited component and applicable maintenance standard were correctly identified
  • Whether repairs, inspections or other contemporaneous records change the factual assessment
  • Compare the original summons, issue/service dates and the complete inspector narrative with each document; do not assume any potential defense is established without proof.

Correction and DOB closeout strategy

  • Correct unsafe conditions and protect affected occupants or the public without waiting for a hearing.
  • Choose appropriate repair professionals/permits, verify whether reinspection or Certificate of Correction is needed, and retain proof.

Determine whether DOB requires a Certificate of Correction, a separate reinspection, application/permit sign-off or an order-lift. An OATH outcome, a paid fine and physical correction are separate issues.

Evidence and documents tailored to this allegation

  • door/exit photographs and approved egress plans
  • approved wet-room layouts and plumbing/alteration permits
  • time-stamped photographs of the specific alleged condition
  • maintenance and repair tickets, invoices and professional findings
  • prior complaints, reports and permit history where relevant
  • dated post-correction photographs and agency compliance records

Pending in source: what to verify before acting

The November 10 extract lists the hearing as PENDING. Confirm its present scheduling, appearance method, adjournment/settlement rules and evidence deadlines directly with OATH.

Need a summons-specific action plan? For 039206441M, Building Violation LLC can scope building-maintenance hearing review and documented correction closeout after reviewing the actual notice and current DOB/OATH record.

Request help with unsafe condition / maintenance at 755 Oakland Place, Bronx, NY 10457
Focused NYC DOB and OATH resolution services

Resolve the actual issue at 755 Oakland Place, Bronx, NY 10457 — not just the summons number

For this property, start with fire alarm / sprinkler / suppression and 1 additional issue categories. Building Violation LLC can assess an authorized paid scope for OATH hearing preparation/representation, source-record research and correction coordination appropriate to the individual allegations. A hearing defense and a DOB compliance closeout may both be necessary.

  • Fire alarm / sprinkler / suppression (1 source summons): Fire-protection summons review and licensed-contractor compliance coordination.
  • Unsafe condition / maintenance (1 source summons): Building-maintenance hearing review and documented correction closeout.

What to send for an assessment: Bring the original summonses, current OATH notices, available DOB records and photos tied to the alleged condition. The source-listed hearing date: December 18, 2026.

Services may require separate licensed-trade, architect/engineer or attorney involvement. No outcome, penalty reduction, permit or agency approval is guaranteed; professional fees and scope are confirmed before work.

Official NYC verification resources

Verify the current OATH / DOB record

This is a point-in-time source extract, not a live court calendar. Confirm the date, appearance method, hearing status, penalties and correction requirements directly with the government before taking action.