Normalized ten-character lookup: 039159272L (infraction 102)
Source allegation and actual cited law
The cited condition concerns exterior walls, facade elements, parapets or critical-examination obligations. Key locations/components named in the source: exterior masonry.
Inspector narrative as preserved in source data
OBSERVED AT EXPOSURE#1 DECORATIVE EDGE AT PARAPET LEVEL IN A STATE OF DISREPAIR WITH PIECES DETERIORATING AND FALLING., REPAIR AND/REPLACE; MAKE REPAIRS
This is the narrative supplied in the dataset; verify it against the actual signed summons and inspector attachments.
- 102 — 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER
- Issue date
- September 4, 2025
- Service date
- September 4, 2025
- Source severity
- CLASS - 1
- Source violation type
- Construction
- Hearing status in extract
- DEFAULT
- DOB/ECB status in extract
- ACTIVE
- Correction certification in extract
- NO COMPLIANCE RECORDED
- Penalty field in extract
- $12,500.00
- Balance field in extract
- $12,520.00
Penalty and balance are fields in the supplied November 10 extract—not independently verified current fines, final adjudications or amounts presently owed.
Safety priority: Class 1 in source — treat any alleged immediately hazardous condition as urgent; verify specific DOB correction requirements.
What the alleged violation means at 40-04 Ditmars Boulevard, Queens, NY 11105
Separate physical hazards (such as loose masonry or appurtenances) from periodic report or amendment-filing allegations; the exact law references and notice determine the required response. Key locations/components named in the source: exterior masonry. Record-specific inspection detail: Inspector text begins: “OBSERVED AT EXPOSURE#1 DECORATIVE EDGE AT PARAPET LEVEL IN A STATE OF DISREPAIR WITH PIECES DETERIORATING AND FALLING., REPAIR AND/REPLACE; MAKE REPAIRS”
Possible defense questions and factual disputes to investigate
The following are issues to verify, not assurances that a defense applies to summons 039159272L.
- Whether the specific facade element or inspection/report obligation was correctly identified
- Whether applicable inspection or FISP filings were submitted and accepted on time
- Whether a protective shed, hazard notice or unsafe-condition order applies separately
- Compare the original summons, issue/service dates and the complete inspector narrative with each document; do not assume any potential defense is established without proof.
Correction and DOB closeout strategy
- Safeguard pedestrians and tenants promptly if a potentially unsafe exterior condition exists.
- Engage an appropriate registered design professional and qualified contractor for required assessments, repair plans, permits, filings and reinspections.
Determine whether DOB requires a Certificate of Correction, a separate reinspection, application/permit sign-off or an order-lift. An OATH outcome, a paid fine and physical correction are separate issues.
Evidence and documents tailored to this allegation
- photographs by elevation and facade professional repair reports
- facade/critical-examination reports, amendments and acceptance receipts
- photographs with elevation/exposure labels and dated repair records
- QEW or design professional evaluations and DOB correspondence
- sidewalk shed or protection documentation if relevant
Default recorded in source: what to verify before acting
A DEFAULT entry can affect procedural options; determine when and how default was entered and consult official OATH rules about any available vacate-default application. Do not assume the source-listed December date is still a live hearing.
Need a summons-specific action plan? For 039159272L, Building Violation LLC can scope facade summons and FISP/repair-filing coordination after reviewing the actual notice and current DOB/OATH record.
Request help with facade / exterior wall safety at 40-04 Ditmars Boulevard, Queens, NY 11105